Records from 2016 to 2026. Most recent: inspection, 16 June 2026.
Documentation record
Registered dimensions (L × B × D)90.0 ft × 27.9 ft × 9.1 ft
Registered tonnagegross 91 / net 61
ITC dimensions (L × B × D)90.0 ft × 27.9 ft × 9.1 ft
ITC tonnagegross 181 / net 64
BuilderDUCLOS CORP · SOMERSET, MA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 6 August 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it0 - Simplified, Gross Ton
181 - Convention (Subpart B), Gross Ton
91 - Regulatory (Subpart C or D), Gross Ton
0 - Simplified, Net Ton
64 - Convention (Subpart B), Net Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 48
16 June 2026
Deficiency Check · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8406017
11 December 2025
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8279297
3 December 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8273847
28 July 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8193357
16 December 2024
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8040673
13 December 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7828055
20 September 2023
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7795024
10 July 2023
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7738445
22 April 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7674518
28 October 2022
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7585540
29 September 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7562693
16 July 2022
Damage Survey · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7509699
15 July 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7508489
11 July 2022
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7503322
5 July 2022
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7522165
30 November 2021
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7344148
30 September 2021
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7329007
1 March 2021
DAPI Audit · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7148865
20 November 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7099006
18 November 2020
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7097449
19 December 2019
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6875112
5 December 2019
Damage Survey · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6874482
16 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6835422
30 September 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6810973
20 November 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6584009
12 September 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6539780
1 July 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6462298
1 July 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6464833
17 June 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6446694
16 June 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6445684
2 June 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6432160
1 June 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6431524
16 May 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6416573
14 May 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6414986
16 April 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6392984
11 April 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6390072
27 March 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6379502
16 March 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6372998
21 February 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6359176
13 February 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6354287
2 February 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6348439
2 February 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6348461
29 January 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6345535
9 January 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6335341
22 November 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6311442
26 October 2017
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6295429
13 October 2017
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6285303
11 September 2016
Initial Construction-Excluding Oversight · Plan Review "T" Boat · Deadweight Survey · Initial Certification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6265205
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2026
Resolved
The OCMI may require an inspection and testing whenever a repair or alteration is undertaken. Vessel is currently inop due to casualties on jet drive shaft seals in both hulls; after repairs are complete, a full underway power trial witnessed by a USCG Marine Inspector is required prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2026
Resolution: Power trials were conducted in the presence of a CGMI; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 December 2024
Resolved
A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or other standard specified by the Commandant. The hydrostatic release units on the vessel were expired Replace hydrostatic release units to the satisfaction of the attending marine inspector. Vessel is limited to one nautical mile from shore until rectified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2024
Resolved 31 December 2024
Resolution: Operator replaced hydrostatic release units.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 December 2024
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. The vessel has fuses for the vessel's wifi system that are of the blade type. Replace fuses with proper fuses to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2025
Resolved 30 January 2025
Resolution: OCMI confirmed that the blade fuses are protected upstream by approved UL breakers in accordance with approved plans.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 September 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Marine Inspector observed a porosity on the inner most forward weld in the middle STBD void. Must be ground out and re-welded to the satisfaction of the Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 22 September 2023
Resolution: Photo Provided showing repair is satisfactory to the MI, see "Documents".
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 September 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Marine Inspector observed forward Port gunwale was damaged with protruding metal that could result in damage to the hull within the vicinity of the protruding metal. Repairs must be made to the satisfaction of the Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 22 September 2023
Resolution: Photo Provided showing repair is satisfactory to the MI, see "Documents".
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 March 2021
Resolved
All agreements and arrangements, written or unwritten, between and among employers and service agents concerning the implementation of DOT drug testing requirements are deemed, as a matter of law, to require compliance with all applicable provisions of this part and DOT agency drug testing regulations. Company currently does not have a valid contract with their C/TPA on file or a Letter of Regulatory Compliance with their C/TPA on file.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2021
Resolved 9 March 2021
Resolution: Received documentation with updated TPA contract with LORC.
Stability › Incline Test › General
Issued 11 September 2016
Resolved
Provide approved Stability letter.
Condition: Invalid
Due 25 September 2017
Resolved 27 September 2017
Navigation › Piloting/Steering › Maneuverability Rating
Issued 11 September 2016
Resolved
Provide Operation Manual for high speed craft.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 13 October 2017
Resolution: Vessel was restricted to less than 30 knots in COI.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 September 2016
Resolved
Provide proof of Drug and Alcohol testing program.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 13 October 2017
Resolution: Provided.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 September 2016
Resolved
Complete New to Zone Inspection
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 13 October 2017
Resolution: completed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 September 2016
Resolved
Complete MOB and Fire Drill
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 13 October 2017
Resolution: Completed drills during new to zone inspection.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 11 September 2016
Resolved
Verify appropriate manning level.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2017
Resolved 13 October 2017
Resolution: verified.