Records from 2017 to 2025. Most recent: inspection, 2 February 2025.
Inspection history · 13
2 February 2025
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8073241
12 April 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7667418
11 April 2023
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7662296
5 January 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7376172
27 January 2020
Random ISPS/MTSA/PSC
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6896723
17 May 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6686255
17 May 2019
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6686401
9 May 2019
Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6680073
6 November 2018
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6575275
23 April 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6397268
1 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6298954
27 August 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6254312
8 March 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6098955
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 May 2019
Resolved
74SOLAS(14)II-2/14.2.1.2 - Fixed firefighting systems & appliances shall be kept in good working order & readily available for immediate use. Emergency fire pump is unable to supply firefighting water due to clogged filter. 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2019
Resolution: Emergency fire pump repaired and satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 May 2019
Resolved
74SOLAS(14)I/11(a) - The condition of the ship & it's equipment shall be maintained to conform with the provisions of the present regualtions to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported being aground while moored at the pier. Provide dive survey report.
17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2019
Resolution: Dive survey conducted. NSTR.