Records from 2017 to 2026. Most recent: inspection, 23 July 2026.
Inspection history · 52
23 July 2026
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8444575
29 June 2026
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8418912
8 June 2026
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8394613
25 November 2025
MSP Annual Oversight · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8273868
19 November 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8272296
22 October 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8257180
21 May 2025
ISM SMC Audit · Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8143172
1 April 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8103588
5 February 2025
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8074840
13 December 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8046965
4 December 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8043399
1 December 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 8041675
17 November 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8035784
14 November 2024
MSP Annual Oversight · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8035017
3 September 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7995046
24 July 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7966188
3 June 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7927794
28 May 2024
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7921287
18 April 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7897930
8 December 2023
Annual Inspection · MSP Annual Oversight
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7838660
9 November 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7878417
17 September 2023
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7793092
28 August 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7787851
14 August 2023
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 7825642
10 April 2023
Deficiency Check · Administrative Inspection
Physical examination · Activities Europe · Activity 7666309
24 February 2023
Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7650556
21 November 2022
MSP Annual Oversight · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7595655
12 August 2022
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7554834
27 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7523353
26 May 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7459427
9 April 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7427982
4 October 2021
MTSA/ISPS Verification · MSP COI Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7326387
10 February 2021
MSP Annual Oversight · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7138770
20 November 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7100446
1 June 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6965075
21 April 2020
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6941748
19 February 2020
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6911415
10 February 2020
MARPOL Annex VI Survey · MSP Select Handover Survey · Periodic Inspection · Ballast Water Examination · MTSA/ISPS Verification · MSP Periodic Oversight · MARPOL Annex I Examination · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6906052
27 December 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6879646
1 February 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6659287
29 January 2019
Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · MSP Annual Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6617517
7 January 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6606842
18 July 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6483658
14 July 2018
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6478599
24 April 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6402220
16 January 2018
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6337064
1 January 2018
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 6331447
21 December 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6327677
11 September 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6284870
6 June 2017
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6162203
6 June 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6167775
6 January 2017
MTSA/ISPS Verification · Reflagging & Initial Certification · MSP Initial Reflag · COI Inspection
Physical examination · Activities Europe · Activity 6066767
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 5 November 2021
Resolved
The company and the ship shall comply with the
requirements of the ISM Code. The company should
establish procedures, plans and instructions, including
checklists as appropriate, for key shipboard operations.
Marine Inspector observed 28 monitoring points that were
inhibited on the engine room automation system dating to
a M/E thrust bearing temp inhibited point in Feb 2021.
There was no evidence of a procedure, tracking or
reporting system regarding the inhibition of alarm and
monitoring points in the automation system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 January 2022
Resolution: Received DNV survey report attesting to automation functionality. Additionally, the company implemented procedures relevant to the inhibition of automation items.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 January 2019
Resolved
While conducting the inspection,the vessel grounded after dragging anchor. The vessel must submit a dive report and atest the overall condition of the vessel is ready for sea IAW 46 CFR 91.27-15.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2019
Resolution: Received dive report. No deficiencies identified.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 30 January 2019
Resolved
No repairs or alterations, except in an emergency shall be made to any lifesaving or fire detecting or extinguishing equipment without notice to the [name withheld] boat davit fall was replaced in October 2018 due to heavy corrosion. No notification was made to the Coast Guard. Also proper weight test must be performed IAW 46 CFR 97.30-10 and 46 CFR 199.45(c)(1).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2019
Resolution: Observed 110% static load test alongside manufacturer.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 30 January 2019
Resolved
Due to the deficiencies found during the inspection per ISM code chapter 9, the CG recommends an internal audit of the vessel's SMS. Any results shall be sent to the CG.
Action required: 702 - Prior to embarking on international voyage
Resolved 1 February 2019
Resolution: Received supplemental ISM audit.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 30 January 2019
Resolved
Posters or signs shall be provided on or in vicinity of survival craft and their launching controls and shall illustrate the purpose of controls and the procedures for operating the appliance and give relevant instructions or warnings. Free fall lifeboat releasing instructions are wasted away and cannot be read IAW 74 SOLAS(14) III/9.2.1
Action required: 702 - Prior to embarking on international voyage
Resolved 31 January 2019
Resolution: Observed new placard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 January 2019
Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. The aft port door leading into the stairway on the cargo deck #10 was equipped with a hold back hook and did not properly close. Door must be repaired and prove proper working order IAW 74 SOLAS(14) II-2/4.2.2
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
Resolution: Verified operation of door.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 30 January 2019
Resolved
The cook and steward were not familiar with the fire suppression systems and equipment located in the galley. The vessel shall provide training to the cook and steward per vessel's fleet safety manual IAW 74 SOLAS(14) III/4.2.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2019
Resolution: Verified training had been given to cook and steward.
01 - Certificates & Documentation › 013 - Documents › Unattended Machinery Spaces (UMS) Evidence
Issued 30 January 2019
Resolved
The vessel's machinery plant is automated to the degree and has been approved for periodically unattended and reduced manning as per part 62 of 46 CFR. It is unknown if the machinery plant's USCG approved periodic safety test procedures(PSTP) are being completed annually. The vessel must provide documentation proving that all PSTPs are being completed on an annual basis ensuring machinery plant reliability IAW 74 SOLAS(14) II-1/46.3 and 46 CFR 61.40-6.
Action required: 702 - Prior to embarking on international voyage
Resolved 31 January 2019
Resolution: Vessel provided temporary plan moving forward to track all PSTP's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 30 January 2019
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Free fall lifeboat releasing gear was iced over and not ready for immediate use IAW 74 SOLAS(14) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 30 January 2019
Resolution: Ice was broken up which allowed the releasing gear to be accessible.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 14 July 2018
Resolved
Vessel has sailed from Jacksonville, FL to Beaumont, TX with a foreign mariner acting as an officer of the watch. The vessels next port is also US port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2018
Resolution: [name withheld] aboard the vessel.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 26 January 2017
Resolved
Provide adequate emergency lighting at all stowage positions for firemen's outfits.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 May 2017
Resolved 3 March 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 26 January 2017
Resolved
Prove readiness/proper operation of rescue boat and lifeboat by maneuvering in water with operating crew.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 February 2017
Resolved 1 February 2017
Resolution: Cleared via e-mail of video