EVER HARMONY is a 2005 freight ship. The Coast Guard has recorded 18 inspections since 2016, most recently in July 2022, along with 7 deficiencies and 2 operational controls, 1 with no removal date recorded.
Records from 2016 to 2022. Most recent: inspection, 15 July 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it21385 - Convention (Subpart B), Gross Ton 33532 - Dead Weight, Metric Ton 40670 - Displacement, Metric Ton 11444 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 30 March 2021Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500 l and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. In the vessel’s fire control station, PSCO observed the air bottle used to close the engine room’s fuel oil tank was empty and would not have operated as designed if used during an emergency.
Action required: 10 - Deficiency Rectified
Resolved 30 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2021Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. DURING THE INBOUND TRANSIT TO DELAWARE BAY THE VESSEL EXPERIENCED AN INABILITY ON SEVERAL ATTEMPTS TO RESPOND TO THE COMMAND TO GO ASTERN.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 25 March 2021
Resolved 30 March 2021
Resolution: Class attended and determined the cause of the deficiency were fuel injection valves that were not properly atomizing fuel. The crew replaced all injection valves of the main engine.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 12 December 2017Resolved
1430-Each emergency generator set shall have a second source of energy provided for an additional three starts within 30 minutes. PSCO observed that the second means to start the emergency generator is a battery set. The crew was not able to start the emergency generator using the second source of energy. 74 SOLAS(04) II-I/44.2
Condition: Improper/Lack of Maintenance
Due 12 December 2017
Resolved 12 December 2017
Resolution: Cleared on the spot. Crew replaced batteries with new batteries and demonstrated 3 consecutive starts using the new batteries.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 12 December 2017Resolved
0936- the angular position of the rudder shall be recognizable in the steering gear compartment. PSCO observed the rudder angle indicator bolt sheared on the port side of the rudder angle indicating device causing it to list when the rudder is swung from side to side. When the rudder was swung from the bridge the rudder angle indicator on the bridge shows a 3 degree difference than the local steering gear indicator. When the rudder was swung to port, the PSCO observed loud noises and the ram does not move smoothly. 74 SOLAS (04)II-I/29.11.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 February 2018
Resolved 27 February 2018
Resolution: RCVD CLASS RPT STATING RUDDER ANGLE INDICATOR WAS ADJUSTED AND TESTED SATISFACTORILY.
1730-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention without presenting an unreasonable threat of harm to the marine environment. PSCO observed the oil water separators oil content meter is giving error code (E3)when tested. The crew was not able to demonstrate proper operation of the equipment. MARPOL I/6.4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2017
Resolution: PSCO witnessed proper operation of the OWS and received Class Report attesting to repairs.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 2 May 2016Resolved
0740- pumps - 17a - fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO noted ship's crew could not get the emergency fire pump to provide pressure while the vessel was in ballast. 74 SOLAS am II-2/14.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2016
Resolved 3 May 2016
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 May 2016Resolved
1499-other- 16a (prop & aux. Machinery- 16a - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fir o proceed to sea without danger to the ship or persons on board. PSCO observed that the ventilation fan for the emergency generator room was inoperable. 74SOLAS am 1/11.a
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 3 May 2016
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.