Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 22 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ7419
1445063
Flag
UNITED STATES
Maury page id
psix-1445063

Documentation record

Registered dimensions (L × B × D)53.8 ft × 24.0 ft × 8.0 ft
Registered tonnagegross 90 / net 72
ITC dimensions (L × B × D)53.8 ft × 24.0 ft × 8.0 ft
ITC tonnagegross 126 / net 99
BuilderJANTRAN INC · ROSEDALE, MS, UNITED STATES · built 2017
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portCATOOSA, OK
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 September 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Simplified, Gross Ton
126 - Convention (Subpart B), Gross Ton
72 - Simplified, Net Ton
99 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

A F 12 Tank Barge · MISLE 45097 · 22 May 2019 · activity 6712877SD 15 Tank Barge · MISLE 45726 · 22 May 2019 · activity 6712877CAPT. KENNY CADY Towing Vessel · MISLE 75452 · 22 May 2019 · activity 6712877MTC 7256 Freight Barge · MISLE 1008597 · 22 May 2019 · activity 6712877LTD 11140 Freight Barge · MISLE 1126591 · 22 May 2019 · activity 6712877

Inspection history · 12

22 July 2026 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8447736
5 June 2025 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8153547
9 July 2024 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7954469
17 July 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7744718
8 June 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7714282
21 June 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7483930
18 May 2021 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7201395
14 July 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6984917
15 January 2020 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6890943
22 May 2019 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6712877
19 June 2018 Deficiency Check · Administrative Inspection · MTSA/ISPS Verification · Initial Certification · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6459081
30 January 2018 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6346564

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2023 Resolved
Fire Hoses observed leaking from the pressed brass fitting connection on the nozzle end.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 26 July 2023
Resolution: Company purchased and installed new fire hoses.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 July 2023 Resolved
First aid kit contained expired eye wash solution.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company purchased new eye wash solution.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2023 Resolved
Both Lifebuoy lights were found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company purchased and installed CG approved lights.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2023 Resolved
02 portable fire extinguishers located in the engineroom were found missing annual servicing tag/records.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company had fire service technicians intall service tags.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2023 Resolved
Required lifejackets (05) were found with expired lights attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 7 August 2023
Resolution: Company purchased and installed new lifejacket lights for all PFD's onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2023 Resolved
No records made available indicating the pressure relief valve on the pressure vessel was tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company installed new pressure relief valves.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 June 2022 Resolved
The semi-portable fire extinguishing system was not found onboard. Determined that it was being serviced at a servicing facility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Semi-portable extinguisher installed onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2022 Resolved
Shaft seals observed to be leaking excessive water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Shaft seal packing replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2022 Resolved
Life buoys were found with no retro-reflective material installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Retro was installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 June 2022 Resolved
High level bilge alarm was found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 23 June 2022
Resolution: Vessel found the correct way to test the alarm was able to show that the high level bilge alarm worked prior to team departing.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2020 Resolved
Replace first aid kit
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Company replaced first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 July 2020 Resolved
Install life ring lights
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 4 September 2020
Resolution: Company installed lights on ring life buoys.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 July 2020 Resolved
Conduct Annual Man overboard drills
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 14 July 2020
Resolution: Vessel's crew conducted man overboard drill.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 July 2020 Resolved
Replace air compressor safety relief valve
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 5 August 2020
Resolution: Company replaced Safety Relief Valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2020 Resolved
Secure Bilge wiring to no become loose in transit
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 14 July 2020
Resolution: Wiring was better supported to not become loose durring transit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 July 2020 Resolved
Replace Navigation Light Bulbs
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 14 July 2020
Resolution: Navigation light bulbs were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 July 2020 Resolved
Repair Life Ring Bracket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 5 August 2020
Resolution: Repairs made to ring life bouy brackets.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 19 June 2018 Resolved
The sign for the engine room general alarm must read "Attention General Alarm - When Alarm Sounds or Flashes Go To Your Station." Replace sign to read exactly that.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 28 June 2018
Resolution: Vessel replaced sign with one that reads the correct verbage
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 June 2018 Resolved
Fuel shutoff valve is incorrectly marked as "fire supression system." Remove current markings and mark as fuel shutoff.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 28 June 2018
Resolution: Vessel removed incorrect markings for the fuel shutoffs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 June 2018 Resolved
Captain is required to hold a FCC Radio operator permit. Have the captain obtain a FCC Radio Operator Permit. 47 CFR 80.163
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 28 June 2018
Resolution: Captain recieved FCC Radio License
01 - Certificates & Documentation › 011 - Ships Certificates › International Sewage Pollution Prevention Cert.
Issued 19 June 2018 Resolved
Placard for the MSD was not available for inspection. Provide evidence of the operating placard being onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 28 June 2018
Resolution: Vessel provided pictures of the MSD placard being onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.