Documentation record
Registered dimensions (L × B × D)53.8 ft × 24.0 ft × 8.0 ft
Registered tonnagegross 90 / net 72
ITC dimensions (L × B × D)53.8 ft × 24.0 ft × 8.0 ft
ITC tonnagegross 126 / net 99
BuilderJANTRAN INC · ROSEDALE, MS, UNITED STATES · built 2017
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portCATOOSA, OK
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 September 2025 · expires 31 August 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Simplified, Gross Ton
126 - Convention (Subpart B), Gross Ton
72 - Simplified, Net Ton
99 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 12 inspections, each with its date, unit and type; 21 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 5 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 12
22 July 2026
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8447736
5 June 2025
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8153547
9 July 2024
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7954469
17 July 2023
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7744718
8 June 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7714282
21 June 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7483930
18 May 2021
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7201395
14 July 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6984917
15 January 2020
Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6890943
22 May 2019
Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6712877
19 June 2018
Deficiency Check · Administrative Inspection · MTSA/ISPS Verification · Initial Certification · COI Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6459081
30 January 2018
Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6346564
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2023
Resolved
Fire Hoses observed leaking from the pressed brass fitting connection on the nozzle end.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2023
Resolved 26 July 2023
Resolution: Company purchased and installed new fire hoses.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 July 2023
Resolved
First aid kit contained expired eye wash solution.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company purchased new eye wash solution.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2023
Resolved
Both Lifebuoy lights were found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company purchased and installed CG approved lights.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2023
Resolved
02 portable fire extinguishers located in the engineroom were found missing annual servicing tag/records.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company had fire service technicians intall service tags.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2023
Resolved
Required lifejackets (05) were found with expired lights attached.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 7 August 2023
Resolution: Company purchased and installed new lifejacket lights for all PFD's onboard.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2023
Resolved
No records made available indicating the pressure relief valve on the pressure vessel was tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 26 July 2023
Resolution: Company installed new pressure relief valves.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 June 2022
Resolved
The semi-portable fire extinguishing system was not found onboard. Determined that it was being serviced at a servicing facility.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Semi-portable extinguisher installed onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2022
Resolved
Shaft seals observed to be leaking excessive water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Shaft seal packing replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2022
Resolved
Life buoys were found with no retro-reflective material installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Retro was installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 June 2022
Resolved
High level bilge alarm was found inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2022
Resolved 23 June 2022
Resolution: Vessel found the correct way to test the alarm was able to show that the high level bilge alarm worked prior to team departing.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2020
Resolved
Replace first aid kit
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 5 August 2020
Resolution: Company replaced first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 14 July 2020
Resolved
Install life ring lights
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 4 September 2020
Resolution: Company installed lights on ring life buoys.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 14 July 2020
Resolved
Conduct Annual Man overboard drills
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 14 July 2020
Resolution: Vessel's crew conducted man overboard drill.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 14 July 2020
Resolved
Replace air compressor safety relief valve
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 5 August 2020
Resolution: Company replaced Safety Relief Valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 July 2020
Resolved
Secure Bilge wiring to no become loose in transit
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 14 July 2020
Resolution: Wiring was better supported to not become loose durring transit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 July 2020
Resolved
Replace Navigation Light Bulbs
Action required: 10 - Deficiency Rectified
Due 28 July 2020
Resolved 14 July 2020
Resolution: Navigation light bulbs were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 July 2020
Resolved
Repair Life Ring Bracket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 5 August 2020
Resolution: Repairs made to ring life bouy brackets.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 19 June 2018
Resolved
The sign for the engine room general alarm must read "Attention General Alarm - When Alarm Sounds or Flashes Go To Your Station." Replace sign to read exactly that.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 28 June 2018
Resolution: Vessel replaced sign with one that reads the correct verbage
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 June 2018
Resolved
Fuel shutoff valve is incorrectly marked as "fire supression system." Remove current markings and mark as fuel shutoff.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 28 June 2018
Resolution: Vessel removed incorrect markings for the fuel shutoffs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 June 2018
Resolved
Captain is required to hold a FCC Radio operator permit. Have the captain obtain a FCC Radio Operator Permit.
47 CFR 80.163
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2018
Resolved 28 June 2018
Resolution: Captain recieved FCC Radio License
01 - Certificates & Documentation › 011 - Ships Certificates › International Sewage Pollution Prevention Cert.
Issued 19 June 2018
Resolved
Placard for the MSD was not available for inspection. Provide evidence of the operating placard being onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 July 2018
Resolved 28 June 2018
Resolution: Vessel provided pictures of the MSD placard being onboard.