ELIN LEIGH

ELIN LEIGH is a 1976 towing vessel. The Coast Guard has recorded 31 inspections since 1991, most recently in March 2026, along with 21 deficiencies and 1 casualty investigation in 2013.

Records from 1991 to 2026. Most recent: inspection, 2 March 2026.

Built
1976
Last inspected
2 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 2 March 2026
…with no type recorded21
Operational controls None recorded without a removal date
Years with a record 19 calendar years (1991–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC4973
145590
Flag
UNITED STATES
Maury page id
psix-145590

Documentation record

Registered dimensions (L × B × D)44.7 ft × 20.0 ft × 6.7 ft
Registered tonnagegross 58 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNITED SHIPBUILDING · VINTON, LA, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBAYTOWN, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 July 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 31

2 March 2026 COI Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8318463
13 June 2025 Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8158424
4 June 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7927033
11 May 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7685786
24 February 2023 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7641660
13 July 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7506030
13 June 2022 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7476475
20 September 2021 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7376467
9 March 2021 Administrative Inspection · COI Inspection · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7157324
13 November 2019 Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 6856279
15 April 2017 Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 6125466
13 January 2014 Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4782355
3 October 2013 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4728308
20 September 2013 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4727735
13 February 2013 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4533010
10 September 2012 Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4437545
19 January 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3396532
5 April 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1609893
23 December 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1478015
18 November 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 71795
24 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 129996
24 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 206671
24 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 497176
24 March 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 766086
13 February 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 42070
6 April 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 662243
29 March 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 225483
29 March 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 525756
13 April 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 22896
23 February 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 166688
12 July 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 229151

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2025 Resolved
Each towing vessel must have either a self-priming, power-driven, fixed fire pump, (a) A fixed fire pump must be capable of being energized remotely from a safe place outside the engine room and at the pump. Vessel did not have a local start for the fire pump.vessel to enact permenent repairs within 30 days. 46CFR142.325(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2025
Resolved 15 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 June 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures. MI observed inoperable AMP, Hertz and Watt meters on the local switchboard, vessel to enact permenent repairs within 30 days. 46CFR143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2025
Resolved 15 May 2026
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 13 June 2025 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. MI observed low bulkwarks on deck with no safety to prevent crewmember from falling overboard. Vessel to enact permenant repairs within 60 days. 46CFR144.800(a)
Action required: 705 - Other - as specified
Due 13 August 2025
Resolved 15 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 June 2024 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: The control panel includes visual alarm alarms to identify the zone or zones of origin of the fire. Activation of engine room heat sensors were indicated on detection panel as being in the galley, and vice versa. Affect permanent repairs to the satisfaction of a USCG Marine Inspector. 46 CFR 142.330(a)(4)(iii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 20 June 2024
Resolution: Received satisfactory Tech Report as evidence of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2024 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Equipment and electrical cables must be suitably protected from wet and corrosive environments. The eight batteries for both main diesel engines are not within boxes and are not secured in place. Install batteries inside boxes and secure in place to the satisfaction of a USCG Marine Inspector. 46 CFR 143.400(e)(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 20 June 2024
Resolution: Received satisfactory photographs as evidence of repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2022 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. There was no smoke detection installed in the galley area, laundry area, one crew berthing space, or the bridge. Install smoke detectors to the satisfaction of USCG MIs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2022
Resolution: Detectors installed and tested by MIs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2022 Resolved
A towing vessel must carry lifebuoys as follows: A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Lifebuoys must be at least 610 millimeters (24 inches) in diameter. Lifebuoy outside pilot house on the port side was deteriorated and not in serviceable condition.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2022
Resolution: New life buoy installed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 July 2022 Resolved
Piping and machinery components that exceed 428 F must be insulated. A section of the STBD Gen exhaust was not covered, and the newly installed Port Gen exhaust system was missing insulation. Install insulation to the satisfaction of USCG MIs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2022
Resolution: Lagging re-installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 July 2022 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Water lights on lifebuoys did not have compatible batteries installed IAW 161.010 or 161.110. Replace with batteries as indicated on placard of the light.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 July 2022
Resolution: Lights on thebuoys located on the port and stbd side of the pilothouse, were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2022 Resolved
Each remote control valve must be marked in clearly legible letters at least 1 inch high, indicating the purpose of the valve and the way to operate it. Fuel cut off was not marked, label fuel shut off valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 3 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2022 Resolved
Each lifejacket must have the following attachments: a light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. All lifejackets on board were missing lights or the chem lights were expired. Replace and attach approved lights to the satisfaction of USCG MIs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 18 July 2022
Resolution: Lifejacket lights replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 July 2022 Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Based on Table 141.370 vessel required 3 day and 3 night signals. Vessel had expired distress signals for night time use. Replace onboard with 3 red hand flares for use at night.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 3 November 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2022 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. A distribution panel on the bridge and the FWD STBD panel had openings on the panel, place blanks on the panel to the satisfaction of USCG MIs. Additionally, install a cover over the Air Compressor STBD electrical system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 July 2022
Resolution: All blanks were installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 July 2022 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel did not have current publications onboard, they have been ordered.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 18 July 2022
Resolution: Publications placed onboard.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 13 July 2022 Resolved
The following list of items must be recorded in the TVR, official logbook, or IAW the TSMS applicable to the vessel:(4)examinations and tests, IAW 140.615;(5)operative nav safety equipment, IAW 140.620;(6)nav assessment IAW 140.635; (10)Fire-detection & fixed fire-extinguishing, IAW 142.240. Records of items (4)(5)(6)(10) & lifesaving inspections required by 46CFR141.235 were not properly maintained. Records can be found in 3 different locations & not done consistently by captains of the vessel as specified in TSMS. Records could not be found for previous year. Consolidate into one location & ensure records are being kept.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 November 2022
Resolution: Vessel sent in evidence of logs being kept and maintained.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 March 2021 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The system must be arranged and installed so a fire in the engine room automatically sets off alarms on the fire detection control panel at the operating station. The vessel’s fire alarm panel is showing a fault from the engine room. Deficiency to be rectified to the satisfaction of USCG marine inspector prior to vessel movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2021
Resolution: Received techicians report from Hiller [name withheld] attesting to satisfactory repair of the fire alarm panel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 March 2021 Resolved
A 40-B portable fire extinguisher must be located near the room or cabinet used to store paints, coatings, or other flammable or combustible products. Vessel does not have a 40-B fire extinguished located near the paint storage cabinet. Rectify to satisfaction of USCG marine inspectors w/in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 April 2021
Resolved 17 March 2021
Resolution: Vessel provided picture of the installation of the 40-B fire extinguisher at the paint locker, along with purchase receipt.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency condition. Vessel has multiple dead end and exposed electrical wires throughout engine room. Rectify to satisfaction of USCG marine inspectors w/in 30 days.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 April 2021
Resolved 18 July 2022
Resolution: Deadend wiring removed through out engine space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 March 2021 Resolved
The main and auxiliary generator engines must be equipped with RPM gauges at the machinery location. The vessel does not have RPM gauges at the machinery location for any engine. Rectify to satisfaction of USCG marine inspectors w/in 30 days.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 April 2021
Resolved 14 July 2022
Resolution: Vessel installed new generator that was equipped with required gauges.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 9 March 2021 Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crew members are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to on-board fires and flooding, or responding to other threats to life, property, or the environment. Master could not provide any objective evidence of performing drills related to recovering persons from the water. To clear this deficiency, submit to USCG marine inspectors records of drills and instruction as required by 46 CFR 140.420 (g) w/in 30 days.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 April 2021
Resolved 18 July 2022
Resolution: Witnessed satisfactory drill. Records not kept, issued a new deficincy for multiple records and logs. Def cleared.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 9 March 2021 Resolved
Each towing vessel must be fitted with a general alarm that is activated at each operating station and can notify persons onboard in the event of an emergency in any accommodation, work space, and the engine room. The vessel’s general alarm was found to be inoperable. Crew was able to rewire and restored operation of general alarm system. Deficiency cleared.
Action required: 10 - Deficiency Rectified
Resolved 9 March 2021
Resolution: Crew was able to rectify on the spot.

Casualty record · 1

20 September 2013Routine · role: Suspected to be in Violation of Law or Reg · activity 4727735
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

JESSICA LYN (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.