Records from 2005 to 2026. Most recent: inspection, 6 May 2026.
Documentation record
Registered dimensions (L × B × D)54.7 ft × 21.0 ft × 5.7 ft
Registered tonnagegross 80 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderINLAND MARINE CONSTRUCTOR · EVANSVILLE, IN, UNITED STATES · built 1976
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPADUCAH, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 August 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 9
6 May 2026
COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 8351388
19 February 2021
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7145175
19 July 2020
Type not recorded
No type recorded · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 7012138
3 April 2018
Industry Initiated Exam · MTSA Verification · Administration · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 6384494
1 November 2012
Industry Initiated Exam · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 4476806
24 October 2005
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2521986
17 June 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2393400
24 May 2005
Uninspected Other · Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2367789
23 May 2005
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2374594
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 May 2005
Resolved
Provide proof of current vessel documentation. COD on vessel expired as of April 30, 205.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2005
Resolved 31 May 2005
Resolution: Have current COD
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 May 2005
Resolved
Ensure original License is maintained onboard the vessel for each master. (Both masters had photo copies of Lic onboard at time of boarding).
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: Master produced proper documentation
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 May 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: Master Had two pair of glasses in accordance with his license
Documentation › Certificates/Documents › FCC SSL
Issued 24 May 2005
Resolved
Provide proof [name withheld] has a FCC restricted operator's lic.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: [name withheld] produces his FCC Lic.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 24 May 2005
Resolved
Vessel master and operator failed to report vessel grounding. Vessel grounded on 23MAY2005 at 2030 local time. Recieved 3rd party report at 0900 24MAY2005.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2005
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 24 May 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2005
Communications › Audible Communications › Horn/Whistle
Issued 24 May 2005
Resolved
Provide proof of operation of ships whisle. Per master/ company manager statements vessels horn has been inoperative for 1 week. Vessel has been operating without required sound producing devices.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: whistle is working properly
Communications › Audible Communications › Bell
Issued 24 May 2005
Resolved
Vessel is not fitted with a bell as required by by Nav rules.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: Bell was proper size and mounted
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 May 2005
Resolved
Provide an additional Type I PFD for crew on vessel. 3 crew onboard 2 PFD's available.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: vessel has correct number and type of life jackets
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 May 2005
Resolved
IAW 46 CFR 25.25-9 remove Type I pfd's from storage area's and distribute throughout the vessel.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: Vessel made storage racks for the PFD''s
Personnel › Training › Fire Fighting Basic
Issued 24 May 2005
Resolved
Provide Fire Fighting training all hands.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: Vessel/training log was created with FF training logged
Communications › Alarms/Indicators › General Alarm
Issued 24 May 2005
Resolved
Install general alarm required by 46 CFR 27.201
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: Alarms was installed
Communications › Alarms/Indicators › General Alarm
Issued 24 May 2005
Resolved
Provide light and placard for general alarm in engineroom.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: lights have been added
Communications › Alarms/Indicators › Fire Alarm
Issued 24 May 2005
Resolved
Provide PE verification of Fire alarm panel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: Paper work was on board.
Fire Fighting › Remote Fuel Shutoff › General
Issued 24 May 2005
Resolved
Properly locate fuel shutoff valves adjacent to tanks in accordance with 46 CFR 27.207
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 24 October 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 24 May 2005
Resolved
Install either B-V extinguisher of fixed system in Engineroom.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: B-V system was installed on the after bulk head out side the engine room. Hose will reach all area''s of the engine room.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 24 May 2005
Resolved
Provide portable fire pump or install fixed system.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2005
Resolution: pump is correct type and tested for proper operation
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 May 2005
Resolved
Provide for audit DAPI program.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 May 2005
Resolution: Company rep provided all DAPI documentation
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2005
Resolved
Provide light fixures for all hanging lights.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 31 May 2005
Resolution: globes where placed where needed.