← All vessels
KOTA HARUM
KOTA HARUM is a 2002 freight ship. The Coast Guard has recorded 12 inspections since 2018, most recently in March 2025, along with 20 deficiencies and 3 operational controls.
Records from 2018 to 2025. Most recent: inspection, 10 March 2025.
- Built
- 2002
- Last inspected
- 10 March 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 20 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9238636 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9VFF8
1485847
Flag
SINGAPORE
—
Maury page id
psix-1485847
Inspections, by type
…with no type recorded3
Years with a record
4 calendar years (2018–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it13491 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
10 March 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8090838
5 February 2020
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6903802
4 February 2020
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6902151
15 January 2020
Ballast Water Examination · PSC A · ISPS Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6887908
29 November 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6864392
6 November 2019
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6850344
25 October 2019
NPV Safety Exam · ISPS III Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6840719
11 October 2019
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6833110
5 October 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6828656
4 October 2019
MARPOL Annex I Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6827965
20 March 2019
ISPS II Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6646368
15 March 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6369952
Deficiency record · 20
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 January 2020
Resolved
At each location there shall be clear instructions related to the operation of the CO2 fire extinguishing system having regard to the safety of personnel.
The fixed CO2 fire extinguishing system does not have clear instructions for the operation of the system.
74SOLAS(97)II-2/5.1.7
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 January 2020
Resolved
Machinery and other equipment shall be of the design to reduce danger regarding hot surfaces.
The incinderator has a 5cm crack on the right bottom opening of the ash door.
74SOLAS(97)II-1/26.1
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 15 January 2020
Resolved
Ships shall be fitted with a 3GHz radar with means to assist navigation
Ships S-band radar is inoperable
74SOLAS(2014)V/19.2.7.1
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 January 2020
Resolved
Arrangements shall be made where necessary to disconnect automatically from the emergency switchboard.
The SCBA air compressor has an unauthorized electrical installation to the emergency switchboard.
74SOLAS(97)II-1/43.5.5
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 29 November 2019
Resolved
Vessel's S-Band Radar is not operational as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 October 2019
Resolved
Code: 0910, 74SOLAS(04') CH. I, REG. 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. Dogs on second deck weather-tight doors leading outside house need adjusted to prevent water intrusion.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 7 October 2019
Resolved
Code: 0299, ILO Convention No.92: An adequate system of ventilating crew accommodation shall be provided. The system of ventilation shall be capable of maintaining the air in a satisfactory condition and ensuring a sufficiency of air movement in all conditions of weather and climate. Ships air conditioning system is not currently operational and current weather conditions are over 90 degrees Fahrenheit outside and vessel crew spaces are over 87 degrees Fahrenheit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
Resolved
Code: 2550, 74SOLAS(04') CH.I, REG. 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. The port ballast pump is leaking through the packing gland. Secure all water leaks in engine room from pumps and properly remove and dispose of all water and oily waste in bilge to shore prior to departure.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 October 2019
Resolved
Code: 2550, 74SOLAS(04') CH. I, REG. 11: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. The over-board ballast line #127V has an improper patch on a hole that is leaking approximately .25 gallons per minute and is still continuously leaking with temporary repair completed by crew. Repair to the satisfaction of Class.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 7 October 2019
Resolved
Code: 2535, 74SOLAS(04') CH. I, REG. 19 / ISM CODE, PART A, 2.2: Due to the multiple deficiencies of such serious nature found within key components of the vessel Safety Management System, the U.S. Coast Guard requests an external audit of the Safety Management System. The Company should ensure that the policy is implemented and maintained at all levels of the organization, both ship-based and shore-based. The external audit is requested based on the following objective evidence found during expanded examination: Vessel's crew was not following Bilge Management Plan procedures on board. It was also discovered by Port State Control Officer that vessel's crew was not following procedures described under section titled, “Environmental Seals Numbers Logbooks”, in Chapter 4 per vessel’s EPPM for preventing accidental discharge of oily waste from machinery spaces overboard. Port State Control Officer discovered a seal (No. B25720) installed on 01 January 2018 on valve 46V but the valve was tampered with and easily manipulated to the open position without removing or breaking the seal to allow oily waste from starboard bilge well to discharge overboard through the Fire and Bilge, Ballast Pump.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 7 October 2019
Resolved
Code: 2515, 74SOLAS(04') CH. I, REG. 19 / ISM CODE, PART A, 3.3: Due to the multiple deficiencies of such serious nature found within key components of the vessel Safety Management System, the U.S. Coast Guard requests an external audit of the Safety Management System. The Company is responsible for ensuring that adequate resources and shore-based support are provided to enable the designated person or persons to carry out their functions. The external audit is requested based on the following objective evidence found during expanded examination: The vessel’s crew did not receive parts for vital and general system maintenance and repair within an adequate timeframe to address immediate flooding concerns in the machinery spaces and air condition plant for work and living accommodation spaces. The vessel’s master and chief engineer reminded the company on numerous occasions, but delivery of parts was delayed beyond a reasonable time.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 7 October 2019
Resolved
Code: 2525, 74SOLAS(04') CH. I, REG. 19 / ISM CODE, PART A, 5.2: Due to the multiple deficiencies of such serious nature found within key components of the vessel Safety Management System, the U.S. Coast Guard requests an external audit of the Safety Management System. The Company should ensure that the safety management system operating on board the ship contains a clear statement emphasizing the master’s authority. The Company should establish in the safety management system that the master has overriding authority and the responsibility to make decisions with respect to safety and pollution prevention and to request the Company’s assistance as may be necessary. The external audit is requested based on the following objective evidence found during expanded examination: The Chief Engineer did not follow the Bilge Management Plan as described under section “Designated Officer in Charge.” Per the vessel’s Bilge Management Plan, the Master shall be directly responsible for all bilge operations on board the vessel. The Master did not have awareness of all bilge transfer operations.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 October 2019
Resolved
Code: 2515, 74SOLAS(04') CH. I, REG. 19 / ISM CODE, PART A, 10.1: Due to the multiple deficiencies of such serious nature found within key components of the vessel Safety Management System, the U.S. Coast Guard requests an external audit of the Safety Management System. The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The external audit is requested based on the following objective evidence found during expanded examination: The vessel has not been receiving requested machinery equipment and parts in a timely manner, some parts taking over 9 months to arrive on board the vessel, preventing crew from effecting essential repairs to actively leaking vital machinery systems with piping below the waterline, to include awaiting parts for air condition plant for work and living accommodation spaces.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 7 October 2019
Resolved
Code: 2530, 74SOLAS(04') CH. I, REG. 19 / ISM CODE, PART A, 6.3: Due to the multiple deficiencies of such serious nature found within key components of the vessel Safety Management System, the U.S. Coast Guard requests an external audit of the Safety Management System. The Company should establish procedures to ensure that new personnel and personnel transferred to new assignments related to safety and protection of the environment are given proper familiarization with their duties. Instructions which are essential to be provided prior to sailing should be identified, documented, and given. The external audit is requested based on the following objective evidence found during expanded examination: The Port State Control Officers discovered that the ship's Master and Chief Engineer were unfamiliar with their responsibilities defined by the Company's Bilge Management Plan and Chapter 4, paragraph 4.2 in the Company’s Environment Protection Program Manual.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 October 2019
Resolved
Code: 2550, 74SOLAS(04') CH. I, REG. 11: The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. High water alarms in E/R remain activated due to excessive amounts of oily water mixtures and continual accumulation in the machinery bilge.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 4 October 2019
Resolved
Code: 2510, 74SOLAS(04'), CH. IX, REG. 3: THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. THE COMPANY DID NOT ENSURE THAT THE POLICY IS IMPLEMENTED AND MAINTAINED AT ALL LEVELS OF THE ORGANIZATION IN CONTRADICTION TO ISM CODE 2.2.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 4 October 2019
Resolved
Code: 2525, 74SOLAS (04') CH. IX, REG. 3: THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL SAFETY MANAGEMENT CODE. VESSEL MASTER DID NOT MOTIVATE CREW TO OBSERVE COMPANY ISM PLANS AND PROCEDURES IN CONTRADICTION TO ISM CODE 5.1.2.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 October 2019
Resolved
Code: 2110, MARPOL 73/38 (2011), ANNEX I, REG. 17.2.4: The Oil Record Book (ORB) Part I shall be completed on each occasion, whenever any of the following machinery space, operations take place on the ship: discharge overboard or disposal of bilge water in machinery spaces. The vessel's ORB Part I is missing required entries for disposal of bilge water.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 October 2019
Resolved
Code: 2110, MARPOL 73/78 (2011), ANNEX I, REG. 17.4: Each operation shall be fully recorded without delay in the Oil Record Book Part I. Entries required in ORB Part I were not logged as required without delay.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 4 October 2019
Resolved
Code: 2515, 74SOLAS(04') CH. 1, REG. 19 / ISM CODE, PART A, 1.2.2: Due to the multiple deficiencies of such serious nature found within key components of the vessel Safety Management System, the U.S. Coast Guard requests an external audit of the Safety Management System. The safety management objectives of the Company should, provide for safe practices in ship operation and a safe working environment; assess all identified risks to its ships, personnel and the environment and establish safegaurds; and continuously improve safety management skills of personnel ashore and aboard ships, including preparing for emergencies related both to safety and environmental protection. The external audit is required based on the following objective evidence found during expanded examination: The Port State Control Officers identified that the vessel's crew were not following the Safety Management System established by the Company, the Company was not providing adequate support in parts delivery and oversight, and the Master and Chief Engineer were unfamiliar with their responsibilities defined by the Company's Bilge Management Plan and Chapter 4, paragraph 4.2, in the Company's Environment Protection Program Manual and not following the procedures outlined therein.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.