Records from 2018 to 2026. Most recent: inspection, 25 March 2026.
Documentation record
Registered dimensions (L × B × D)36.3 ft × 11.1 ft × 3.3 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE SHIPBUILDING CORP · SALISBURY, MD, UNITED STATES · built 2018
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
25 March 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8332044
17 February 2026
Vessel Attendance · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8311522
8 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8109167
20 August 2024
Examination of Repairs · Damage Survey
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7985868
23 July 2024
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7990865
28 May 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7922581
5 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7861987
24 February 2023
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7641407
15 November 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7594632
14 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7411965
5 April 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7169023
5 June 2020
Annual Inspection · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7008889
15 November 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6859392
17 August 2018
Drydock Exam · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6514764
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests; Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. MI observed both portable fire extinguishers service date expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 25 April 2025
Resolution: Two new fire extinguishers (3A:40-B:C, and 1A:10-B:C) were purchased and installed onboard as confirmed by the attending CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. MI observed aft fire extinguisher located near outboard engines bracket unable to be secured.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 25 April 2025
Resolution: New brackets were purchased and installed for the new extinguishers, as confirmed by the attending CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. MI observed one of three fire buckets to be of 2 gallon capacity.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 25 April 2025
Resolution: Three new 5 gallon buckets were provided onboard, with stencilled labels and lanyards, as confirmed by the attending CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. MI observed no retroreflective material on the ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 25 April 2025
Resolution: Retroreflective tape has been provided on the lifebuoy to the satisfaction of the attending CG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 April 2025
Resolved
Gauges to indicate engine revolutions per minute (RPM) must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. MI observed the engine RPM gauge for the Starboard engine to be inoperable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 25 April 2025
Resolution: New RPM gauge was installed. Engine was started and confirmed working properly to the satisfaction of the attending CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2023
Resolved
Required portable fire extinguishers: operating station - one 10-B:C, machinery space - one 40-B:C.
The vessel's COI requires one 10-B:C and one 40-B:C, but at time of attendance only the 40-B:C extinguisher was available onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2023
Resolution: All portable extinguishers were valid and onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 March 2023
Resolved
A vessel must carry one floating waterlight.
Battery for waterlight attached to ring lifebuoy expired in July 2022.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 24 March 2023
Resolution: Battery was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 March 2023
Resolved
Each portable fire extinguisher must be of an approved type. Each portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats, and which is arranged to provide quick and positive release of the extinguisher for immediate use.
The bracket for the 40-B:C fire extinguisher is wasted
and in need of replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2023
Resolved 24 March 2023
Resolution: Suitable bracket for portable fire extinguisher was added.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 14 March 2022
Resolved
46 CFR 176.610
During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating shall be made available for examination. Identified a small crack in the weld on the bottom port side lower section of ramp approx. 3/8". Repair as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2022
Resolution: Verefied repair of crack in weld on ramp.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 March 2022
Resolved
46 CFR 182.610(b)
Control of the main steering gear must be provided from the operating station. Helm wheel was found broken and needs to be repaired as original.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2022
Resolution: Verified proper repair and operation of helm wheel
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2022
Resolved
46 CFR 182.458(b)
The design, construction and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25. Vessel had 02-12 gallon fuel tanks connected to outboards and 02-9 gallon spare tanks. ABYC H-25 restricts gasoline fuel capacity to 7 gallons.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2022
Resolution: Verefied additional fuel tanks removed from vessel.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 June 2020
Resolved
At time of inspection no licensed operator were onboard due to vessel not operating for season. Did not get vessel u/w to conduct drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2021
Resolution: Conducted all safety drills. All sat.