Records from 1990 to 2026. Most recent: inspection, 13 May 2026.
Documentation record
Registered dimensions (L × B × D)53.0 ft × 21.5 ft × 7.6 ft
Registered tonnagegross 86 / net 58
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPHILLIP DITTA · MADISONVILLE, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 July 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
58 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
13 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8372670
8 May 2025
COI Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8123448
3 February 2025
Hull Examination · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 8074623
16 September 2024
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 8003815
25 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7942368
25 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7696527
16 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7479564
5 May 2021
Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7202589
4 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 7188777
30 January 2020
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 6900377
13 January 2020
Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6888137
31 May 2011
Industry Initiated Exam · Administration · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4028425
19 November 2008
Administration
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3366341
7 June 2007
Uninspected Other
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2954428
8 August 2006
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2739858
22 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2589627
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979778
31 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 162086
14 September 1994
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 370753
31 October 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 51913
24 September 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 537045
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 4 May 2021
Resolved
The master or officer in charge must ensure that all doors designed to be weathertight function properly. The Port & Stbd engineroom and Stbd galley weathertight doors on the main deck superstructure lacked a weathertight seal due to inadequate dog adjustments, thus preventing a weathertight seal. Vessel shall make Port & Stbd engineroom and Stbd galley doors weathertight. 46 CFR 140.610(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 5 May 2021
Resolution: Received objective evidence photos of Port & Stbd engineroom and Stbd galley weathertight doors properly adjusted to make a weathertight seal.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 4 May 2021
Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Vessel's emergency lighting for the Stbd 2nd deck berthing space was inoperable. Vessel shall repair/replace emergency lighting in the Stbd 2nd deck berthing space. 46 CFR 143.410(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2021
Resolved 5 May 2021
Resolution: Received objective evidence photo of emergency lighting for the Stbd 2nd deck berthing space installed and operating properly.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 March 2020
Resolved
Each towing vessel 39.4 feet or more in length must carry onboard and maintain marine charts or maps of the areas to be transited and must be either current editions or currently corrected. Vessel did not have corrected charts or current editions at time of inspection. Vessel shall ensure current or corrected charts are onboard the vessel at all times.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2020
Resolved 31 March 2020
Resolution: Vessel rep submitted email with pictures of current and corrected charts for area of operation.
Lifesaving
Issued 14 September 1994
Resolved
DURING INSPECTION OF PFD'S IT WAS NOTED THAT TWO OF THE FOUR ONBOARD WERE NOT COAST GUARD APPROVED AND WITHOUT PROPER RETRO. THE PFD'S WERE OLD WITH NO APPROVAL STAMP, MADE IN BRAZIL. MK1JWR
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Navigation
Issued 14 September 1994
Resolved
STBD RUNNING LIGHT HAD DEFFECTIVE LENS COVER WHICH DISPLAYED IMPROPER LIGHTING CHARACTERISTICS.
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994