MAURY USCG vessel records
← All vessels

ST. JOHN

Built
1977
Last inspected
31 May 2017
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 May 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7527992
WDI6543
149992
Flag
UNITED STATES
Maury page id
psix-149992

Documentation record

Tonnage as PSIX records it656 - Regulatory (Subpart C or D), Gross Ton
446 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 9 inspections, each with its date, unit and type; 30 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

31 May 2017 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6155633
12 April 2017 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6123423
4 January 2017 Deficiency Check · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6063915
24 October 2016 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6029923
30 September 2016 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6009903
13 July 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5936705
25 May 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5882083
22 April 2016 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5860295
12 April 2016 Examination of Repairs · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5852711

Deficiency record · 30

Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 31 May 2017 Resolved
Both MDE's had mount nuts missing. (double nut)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 8 June 2017
Lifesaving › Lifefloat › Serviceable
Issued 31 May 2017 Resolved
Cracks found in lifefloat with water seepage. Replace prior to carring passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2017
Resolution: Replaced
Lifesaving › Lifebuoys › Stowage
Issued 31 May 2017 Resolved
Line wrapped and tied to lifebuoy and not ready for immediate use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2017
Resolution: Toss bags in place
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 31 May 2017 Resolved
Mast nav lights covered in soot. Clean to show proper visability.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 June 2017
Resolution: lens replaced
Engineering › Fuel Oil Service System › Piping
Issued 4 January 2017 Resolved
Loose bracket on pressure side fuel rail resulting in worn fuel rail wall. Replace immediately to satisfaction of attending inspector. (H) 46 CFR 71.25035 / (F) 46 CFR 53.05
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 4 January 2017 Resolved
Observed oily windings on both Port & Stbd generators. Clean and ID source of oil and secure leak to satisfaction of the attending Marine Inspector. (H) 46 CFR 70.25-1 / (F) 46 CFR 53.05
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 4 January 2017 Resolved
Stbd Main Engine crankcase breather filter box was discovered smoking. Additionally Excessive oil was found around the filter box. Clean area, change filter and ID & secure excessive oil source. (H) 46 CFR 71.25-35 / (F) 46 CFR 58.03
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 January 2017 Resolved
Main Switchboard is missing Interlock. Replace Interlock to satisfaction of attending Marine Inspector. (H) 46 CFR 70.25-1 / (J) 46 CFR 111.70-7(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Seal
Issued 4 January 2017 Resolved
Stbd Generator Engine drip pan gasket leaking. Replace gasket to satisfaction of attending Marine Inspector. (H) 46 CFR 70.25-1 / (F) 46 CFR 58.03
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 January 2017 Resolved
Grab line on top stowed lifefloat is worn/unservicable. Replace to the satisfaction of attending inspector. (W) 46 CFR 199.190
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Engineering › Generator (propulsion-electric) › Wiring
Issued 29 October 2016 Resolved
Chafing gear on stbd generator worn through to conductor. Repair chafing gear and exposed wiring to the satisfaction of a marine inspector.
Condition: Damaged By Earlier Event
Due 29 November 2016
Resolved 9 November 2016
Resolution: All wires damaged wires were properly repaired.
Engineering › Generator (propulsion-electric) › Winding
Issued 29 October 2016 Resolved
Steam clean port and starboard generator windings due to excessive oil and dirt build up.
Condition: Improper/Lack of Maintenance
Due 29 November 2016
Resolved 9 November 2016
Resolution: Both SSDG's were steam cleaned.
Unknown
Issued 29 October 2016 Resolved
Provide technician's report attesting to the proper repair, testing and operation of stbd generator. Prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2016
Resolved 9 November 2016
Resolution: Received tech report attesting to proper repairs.
Engineering › Generator (propulsion-electric) › Winding
Issued 24 October 2016 Resolved
Vessel experienced a starboard generator failure while crossing the Mississippi river at mile marker 87. Upon repair of inoperative generator, the equipment must be examined and tested in the prescence of a United States Coast Guard Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 28 October 2016
Resolution: Received technician's report.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 30 September 2016 Resolved
ground ampmeter on nav light panel not functioning. When test button utilized, ampmeter does not move.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 4 October 2016
Resolution: Electrician attended vessel to troubleshoot. Ampmeter is functioning properly however, the procedure that explains what should happen when test button utilized is incorrect. test instruction rewritten to reflect correct action of meter.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 September 2016 Resolved
Rubber liner on electrical cable powering resuce boat winch torn and exposing wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 10 October 2016
Resolution: Replaced wire and watertight fitting.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 30 September 2016 Resolved
12 volt ground indicator in engine room not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 4 October 2016
Resolution: Electrician attended vessel and corrected issue. Witnessed satisfactory testing of ground indicator.
Lifesaving › Launching Appliances › Falls
Issued 30 September 2016 Resolved
Fall for rescue boat badly defomed. Bird nested. Fall is too long for winch drum and uneccessary causing fall to become bound on drum.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 3 October 2016
Resolution: Installed new fall. Conducted 1.1 load test for 5 min. All sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 July 2016 Resolved
The CO2 room has oily atmosphere which collects on the CO2 bottles, controls, hoses and valves. Provide statement from your fire protection service company that determines if the system is affected by the oils in and on the bottles, valves and hoses. To be completed prior to 23Jul2016.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2016
Resolved 14 July 2016
Resolution: Received documentation from their fire servicing company [name withheld] that the system is operational after being cleaned.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 July 2016 Resolved
Propose a way to eliminate the oily atmosphere and soaked insulation that keeps dripping on the deck. To be completed prior to 13Aug2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: All soaked insulation was removed, This is an A-0 blkhd which requires no insulation so the insulation was not replaced.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 25 May 2016 Resolved
4. To be completed prior to 25Jun2016, Provide compass deviation card to replace the one that fell behind the pilot house window.
Due 25 June 2016
Resolved 13 June 2016
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 May 2016 Resolved
3. To be completed prior the 25Jun2016, Properly repair the MSD chlorine tank, currently lines broken.
Due 25 June 2016
Resolved 13 June 2016
Lifesaving › Launching Appliances › Davit
Issued 25 May 2016 Resolved
2.To be completed prior to 25Jun2016, Properly install upper cable clamp on the rescue boat davit cable, currently backwards.
Due 25 June 2016
Resolved 13 June 2016
Lifesaving › Launching Appliances › Davit
Issued 25 May 2016 Resolved
To be completed prior to 25Jun2016, stencil the rescue boat davit with the latest test date and weight tested.
Due 25 June 2016
Resolved 13 June 2016
Engineering › Steering Gear System › Valve
Issued 22 April 2016 Resolved
Prior to carrying passengers. Prove proper operation of steering system to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Due 22 April 2016
Resolved 26 April 2016
Resolution: Replaced sticking relief valve on steering system.
Engineering › Steering Gear System › Rudder Bearing
Issued 12 April 2016 Resolved
Prior to placing the vessel back into service repair the port rudder bearings and bushings and have examined by USCG Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Port upper and lower bearings and bushings were replaced.
Engineering › Steering Gear System › Cable
Issued 12 April 2016 Resolved
Prior to placing the vessel back into service replace the frayed manual steering cable in the rudder compartment and demonstrate operation to USCG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Steering cable was renewed and tested satisfactorily.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 12 April 2016 Resolved
Clean all six hyd. ramp rams and find and fix hyd. leaks prior to placing vessel back into service, Demonstrate to USCG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: All hydraulic ramps were inspected and tested satisfactorily
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 12 April 2016 Resolved
Replace missing cotter pin on port side ram and check all other cotter pins and wire in all rams for damage and replace as needed. Currently some are notched and could break at any time hard movement of the ram pin happens.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Missing cotter pin and wire were re-install
Engineering › Steering Gear System › Rudder Bearing
Issued 12 April 2016 Resolved
STBD Rudder remove quadrant and determine condition of wear bushing. Prior to placing the vessel back in service and have examined by USCG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Stbd upper bushing and bearing was replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.