Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 31 May 2017
Resolved
Both MDE's had mount nuts missing. (double nut)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 8 June 2017
Lifesaving › Lifefloat › Serviceable
Issued 31 May 2017
Resolved
Cracks found in lifefloat with water seepage. Replace prior to carring passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2017
Resolution: Replaced
Lifesaving › Lifebuoys › Stowage
Issued 31 May 2017
Resolved
Line wrapped and tied to lifebuoy and not ready for immediate use.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2017
Resolution: Toss bags in place
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 31 May 2017
Resolved
Mast nav lights covered in soot. Clean to show proper visability.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 June 2017
Resolution: lens replaced
Engineering › Fuel Oil Service System › Piping
Issued 4 January 2017
Resolved
Loose bracket on pressure side fuel rail resulting in worn fuel rail wall. Replace immediately to satisfaction of attending inspector. (H) 46 CFR 71.25035 / (F) 46 CFR 53.05
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 4 January 2017
Resolved
Observed oily windings on both Port & Stbd generators. Clean and ID source of oil and secure leak to satisfaction of the attending Marine Inspector. (H) 46 CFR 70.25-1 / (F) 46 CFR 53.05
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 4 January 2017
Resolved
Stbd Main Engine crankcase breather filter box was discovered smoking. Additionally Excessive oil was found around the filter box. Clean area, change filter and ID & secure excessive oil source. (H) 46 CFR 71.25-35 / (F) 46 CFR 58.03
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 4 January 2017
Resolved
Main Switchboard is missing Interlock. Replace Interlock to satisfaction of attending Marine Inspector. (H) 46 CFR 70.25-1 / (J) 46 CFR 111.70-7(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Seal
Issued 4 January 2017
Resolved
Stbd Generator Engine drip pan gasket leaking. Replace gasket to satisfaction of attending Marine Inspector. (H) 46 CFR 70.25-1 / (F) 46 CFR 58.03
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 January 2017
Resolved
Grab line on top stowed lifefloat is worn/unservicable. Replace to the satisfaction of attending inspector. (W) 46 CFR 199.190
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 January 2017
Resolved 10 January 2017
Resolution: Item corrected to the satisfaction of attending Marine Inspector.
Engineering › Generator (propulsion-electric) › Wiring
Issued 29 October 2016
Resolved
Chafing gear on stbd generator worn through to conductor. Repair chafing gear and exposed wiring to the satisfaction of a marine inspector.
Condition: Damaged By Earlier Event
Due 29 November 2016
Resolved 9 November 2016
Resolution: All wires damaged wires were properly repaired.
Engineering › Generator (propulsion-electric) › Winding
Issued 29 October 2016
Resolved
Steam clean port and starboard generator windings due to excessive oil and dirt build up.
Condition: Improper/Lack of Maintenance
Due 29 November 2016
Resolved 9 November 2016
Resolution: Both SSDG's were steam cleaned.
Unknown
Issued 29 October 2016
Resolved
Provide technician's report attesting to the proper repair, testing and operation of stbd generator. Prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2016
Resolved 9 November 2016
Resolution: Received tech report attesting to proper repairs.
Engineering › Generator (propulsion-electric) › Winding
Issued 24 October 2016
Resolved
Vessel experienced a starboard generator failure while crossing the Mississippi river at mile marker 87. Upon repair of inoperative generator, the equipment must be examined and tested in the prescence of a United States Coast Guard Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 October 2016
Resolved 28 October 2016
Resolution: Received technician's report.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 30 September 2016
Resolved
ground ampmeter on nav light panel not functioning. When test button utilized, ampmeter does not move.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 4 October 2016
Resolution: Electrician attended vessel to troubleshoot. Ampmeter is functioning properly however, the procedure that explains what should happen when test button utilized is incorrect. test instruction rewritten to reflect correct action of meter.
Electrical › Electrical Distribution System (service) › Cable
Issued 30 September 2016
Resolved
Rubber liner on electrical cable powering resuce boat winch torn and exposing wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 10 October 2016
Resolution: Replaced wire and watertight fitting.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 30 September 2016
Resolved
12 volt ground indicator in engine room not functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 October 2016
Resolved 4 October 2016
Resolution: Electrician attended vessel and corrected issue. Witnessed satisfactory testing of ground indicator.
Lifesaving › Launching Appliances › Falls
Issued 30 September 2016
Resolved
Fall for rescue boat badly defomed. Bird nested. Fall is too long for winch drum and uneccessary causing fall to become bound on drum.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 3 October 2016
Resolution: Installed new fall. Conducted 1.1 load test for 5 min. All sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 July 2016
Resolved
The CO2 room has oily atmosphere which collects on the CO2 bottles, controls, hoses and valves. Provide statement from your fire protection service company that determines if the system is affected by the oils in and on the bottles, valves and hoses. To be completed prior to 23Jul2016.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 July 2016
Resolved 14 July 2016
Resolution: Received documentation from their fire servicing company [name withheld] that the system is operational after being cleaned.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 July 2016
Resolved
Propose a way to eliminate the oily atmosphere and soaked insulation that keeps dripping on the deck. To be completed prior to 13Aug2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 August 2016
Resolved 26 July 2016
Resolution: All soaked insulation was removed, This is an A-0 blkhd which requires no insulation so the insulation was not replaced.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 25 May 2016
Resolved
4. To be completed prior to 25Jun2016, Provide compass deviation card to replace the one that fell behind the pilot house window.
Due 25 June 2016
Resolved 13 June 2016
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 May 2016
Resolved
3. To be completed prior the 25Jun2016, Properly repair the MSD chlorine tank, currently lines broken.
Due 25 June 2016
Resolved 13 June 2016
Lifesaving › Launching Appliances › Davit
Issued 25 May 2016
Resolved
2.To be completed prior to 25Jun2016, Properly install upper cable clamp on the rescue boat davit cable, currently backwards.
Due 25 June 2016
Resolved 13 June 2016
Lifesaving › Launching Appliances › Davit
Issued 25 May 2016
Resolved
To be completed prior to 25Jun2016, stencil the rescue boat davit with the latest test date and weight tested.
Due 25 June 2016
Resolved 13 June 2016
Engineering › Steering Gear System › Valve
Issued 22 April 2016
Resolved
Prior to carrying passengers. Prove proper operation of steering system to the satisfaction of the attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Due 22 April 2016
Resolved 26 April 2016
Resolution: Replaced sticking relief valve on steering system.
Engineering › Steering Gear System › Rudder Bearing
Issued 12 April 2016
Resolved
Prior to placing the vessel back into service repair the port rudder bearings and bushings and have examined by USCG Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Port upper and lower bearings and bushings were replaced.
Engineering › Steering Gear System › Cable
Issued 12 April 2016
Resolved
Prior to placing the vessel back into service replace the frayed manual steering cable in the rudder compartment and demonstrate operation to USCG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Steering cable was renewed and tested satisfactorily.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 12 April 2016
Resolved
Clean all six hyd. ramp rams and find and fix hyd. leaks prior to placing vessel back into service, Demonstrate to USCG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: All hydraulic ramps were inspected and tested satisfactorily
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 12 April 2016
Resolved
Replace missing cotter pin on port side ram and check all other cotter pins and wire in all rams for damage and replace as needed. Currently some are notched and could break at any time hard movement of the ram pin happens.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Missing cotter pin and wire were re-install
Engineering › Steering Gear System › Rudder Bearing
Issued 12 April 2016
Resolved
STBD Rudder remove quadrant and determine condition of wear bushing. Prior to placing the vessel back in service and have examined by USCG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 18 April 2016
Resolution: Stbd upper bushing and bearing was replaced.