Records from 2000 to 2024. Most recent: inspection, 7 May 2024.
Inspection history · 33
7 May 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7889512
8 March 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7152404
2 December 2019
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6866778
7 August 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6775897
14 February 2019
Administrative Inspection · DAPI Audit · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6619959
26 July 2018
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6491903
29 January 2018
Administrative Inspection · DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6345896
5 December 2017
COI Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6314507
16 November 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6308506
18 March 2016
DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5835702
27 October 2014
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5013075
6 August 2014
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4851321
4 February 2009
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3412235
23 April 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3194037
12 March 2008
COI Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3162777
10 October 2006
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2797041
16 June 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2681924
24 January 2006
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2572106
25 October 2005
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2521485
11 October 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2511630
4 October 2005
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2508183
26 September 2005
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2501319
21 June 2005
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2398805
15 June 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2396337
13 June 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2389033
22 May 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2385096
10 May 2005
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2361237
11 July 2003
COI Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2119695
2 January 2003
Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1725215
22 February 2002
Administrative Inspection
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1488379
5 February 2002
Construction Oversight
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1484048
3 January 2001
COI Inspection · Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1408657
26 September 2000
Plan Review "T" Boat
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1053787
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) protect passengers, crew, other persons and the vessel from electrical hazard. Vessels masthead light support bracket is broken and masthead light is supported by tape.
46 CFR 183.200 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 2 January 2020
Resolution: Masthead support bracket replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2019
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter. Flexible cords and cables shall not be used for the following: (a) As a substitute for the fixed wiring of a structure.
Vessel has extension cord hooked to A/C inverter powering PA system.
46 CFR 183.340 (r)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 2 January 2020
Resolution: Inverter and extention cord removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 2 December 2019
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. Vessel has hydraulic fluid leak on main engine radiator hydraulic fan system leaking into bilge.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 2 January 2020
Resolution: Leak repaired.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 December 2017
Resolved
Schedule company wide DAPI Audit with Sector Honolulu to be conducted IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 18 December 2017
Resolution: Company scheduled DAPI Audit on 23 January 2018 after sister vessel's COI Inspection.
Navigation › Piloting/Steering › Marine Charts
Issued 5 December 2017
Resolved
Provide an updated navigation chart for operating areas. 46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 18 December 2017
Resolution: Received picture of updated navigational charts onboard.
Documentation › Certificates/Documents › Permit, Other
Issued 5 December 2017
Resolved
Provide FCC operator's permit. 46 CFR 184.502; 47 CFR 80
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 7 December 2017
Resolution: Vessel owner provided FCC Operator's permit for vessel captain.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 December 2017
Resolved
Ensure hatch covers are installed with securing devices. 46 CFR 179.360(b)(1) & (2).
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 12 December 2017
Resolution: Received picture of hatch covers installed with securing devices.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 December 2017
Resolved
Vessel restricted to carrying no more than 6 passengers until operational control is lifted for operating without a valid COI due to missing annual and dry dock in March 2017. 46 CFR 176.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Operational control lifted in MISLE.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 November 2017
Resolved
1) Vessel may not operate with greater than six passengers until successful completion of a Certificate of Inspection (COI) and a dry-dock inspection. 46 C.F.R. 176.502
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 5 December 2017
Resolution: Vessel satisfactorily completed COI Renewal. TCOI issued on 05 December 2017.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 March 2016
Resolved
Provide 3 adult life jackets to meet COI requirements. Passenger count is restricted to 45.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 6 April 2016
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (hydraulic)
Issued 23 April 2008
Resolved
Prior to conducting passenger operations conduct sea trails in presence of USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 23 May 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 12 March 2008
Resolved
Provide current FCC Safety of Radio Certificate & FCC Operations Permit to US Coast Guard. Vsl. is restricted to a 1000' or less from shore until this req't is met.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 14 May 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 March 2008
Resolved
Prove enrollment of employees on DAPI addendum/consortium.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2008
Resolved 12 March 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 October 2006
Resolved
Repair stern light. Prior to carrying passengers at night.
Action required: 705 - Other - as specified
Resolved 24 October 2006
Resolution: Witnessed satisfactory test of new light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 October 2006
Resolved
Renew eye wash & asprin.
Action required: 705 - Other - as specified
Due 13 November 2006
Resolved 25 October 2006
Resolution: Witnessed valid eye wash & asprin.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 October 2006
Resolved
Repair bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2006
Resolved 24 October 2006
Resolution: Witnessed satisfactory test of new bilge alarm.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 10 October 2006
Resolved
Replace upper radiator hose clamps with proper type.
Action required: 705 - Other - as specified
Due 13 November 2006
Resolved 25 October 2006
Resolution: Witnessed proper type of double hose clamp.
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 10 October 2006
Resolved
Stop water ingress through stuffing tubes IWO steering box.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2006
Resolved 24 October 2006
Resolution: Stuffing tubes tightened by owner, witnessed satisfactory operational test.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 June 2006
Resolved
Provide original COI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2006
Resolved 23 June 2006
Resolution: Owner could not locate original COI issued "COPY" of COI.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 16 June 2006
Resolved
Ensure all employee's are listed on chemical testing agreement.
Action required: 705 - Other - as specified
Due 28 June 2006
Resolved 26 July 2006
Resolution: Received updated drug testing agreement.
Operations/Management › Drills/Instruction › Not Conducted
Issued 16 June 2006
Resolved
Prove drills & crew competancy prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 July 2006
Resolved 21 June 2006
Resolution: Conducted satisfactory drills.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 October 2005
Resolved
No proof of background check complete prior to transferring personnel from Superducks to TrolleyBoats Enterprises. TrolleyBoats did provide information showing where they have requested some background information. Gave company 30 days to receive the required information.
Due 21 November 2005
Resolved 18 November 2005
Resolution: Received required documentation from Marine Employer.
Construction/Loadline › Hull › Bottom Plating
Issued 12 October 2005
Resolved
Brass plug installed in hole in hull for drain. External cracks on P & S bumper brackets.
Action required: 705 - Other - as specified
Due 1 November 2005
Resolved 18 November 2005
Resolution: Front drive shaft well flange cropped off to include area of drain plug. Welded plate over area, test sat. Completed repairs of bumper brackets, all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Discharge Hose/Tube
Issued 11 October 2005
Resolved
Horn broken off of discharge hose.
Action required: 705 - Other - as specified
Due 11 October 2005
Resolved 12 October 2005
Resolution: New hose assembly installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 October 2005
Resolved
Fixed FE 241 system did not have proof of servicing.
Action required: 705 - Other - as specified
Due 11 November 2005
Resolved 12 October 2005
Resolution: Observed valid service tag.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 11 October 2005
Resolved
Radiator & transmission cooler hoses do not have proper hose clamps
Action required: 705 - Other - as specified
Due 11 November 2005
Resolved 14 October 2005
Resolution: Witnessed installation of proper style double hose clamps.
Engineering › Fuel Oil Service System › Piping
Issued 11 October 2005
Resolved
No bonding strap on fuel fill piping.
Action required: 705 - Other - as specified
Due 11 November 2005
Resolved 17 November 2005
Resolution: Bonding wire installed between fill & hull. (Tank is already bonded to hull.)
Engineering › Bilge Water Management System › Hose
Issued 11 October 2005
Resolved
Bilge pump discharge hose leaking.
Action required: 705 - Other - as specified
Due 11 November 2005
Resolved 12 October 2005
Resolution: New hose installed.
Electrical › Electric Supply System (service) › Cable
Issued 11 October 2005
Resolved
Battery cable jacketing removed.
Action required: 705 - Other - as specified
Due 11 November 2005
Resolved 17 November 2005
Resolution: Positive battery cable (powers solenoid) replaced.
Communications › Alarms/Indicators › Propeller Direction Indicator
Issued 4 October 2005
Resolved
Drive lock light inop.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 6 October 2005
Resolution: Drive lock light switch replaced, test sat.
Construction/Loadline › Hull › Bottom Plating
Issued 21 June 2005
Resolved
Hull breach possibly caused by a broken drive shaft u-joint.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 29 August 2005
Resolution: Inspected satisfactory repairs.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 July 2004
Resolved
Carry only 49 total persons, of which 47 can be passengers until seating is added.
Due 15 August 2004
Resolved 3 August 2004
Resolution: Adjusting the COI to reflect the proper passenger count.
Construction/Loadline › Structures › Door
Issued 15 July 2004
Resolved
Provide method of securing the watertight door open during man overboards.
Due 15 August 2004
Resolved 13 August 2004
Resolution: Provided means of securing the watertight door.
Documentation › Certificates/Documents › FCC SSL
Issued 15 July 2004
Resolved
Provide FCC safety certificate.
Due 15 August 2004
Resolved 13 August 2004
Resolution: Provided FCC certificate.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 15 July 2004
Resolved
Provide permit mount for anchor and anchor line.
Due 15 August 2004
Resolved 13 August 2004
Resolution: Provided permit mount of anchor.
Engineering › Bilge Water Management System › Manifold
Issued 15 July 2004
Resolved
Properly label bilge alarms and control panel.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Resolution: Properly labeled alarms and control panel.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 15 July 2004
Resolved
Label deckhand seat, crew only.
Condition: Placed in Improper Service
Due 15 August 2004
Resolved 13 August 2004
Resolution: Labeled deckhand seat.
Fire Fighting › Fire Bucket › Availability
Issued 15 July 2004
Resolved
Provide 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2004
Resolution: Provided buckets.
Lifesaving
Issued 3 January 2001
Resolved
Make vessel available foa a complete Inspection of equipment and proceduresprior to carrying passengers for hire.
Condition: Unknown
Due 1 June 2001
Resolved 28 May 2004