MAURY USCG vessel records
← All vessels

DUCK DYNASTY

Built
2000
Last inspected
7 May 2024
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 May 2024
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH3046
Flag
UNITED STATES
Maury page id
psix-15144

Documentation record

Registered dimensions (L × B × D)38.0 ft × 8.5 ft × 5.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderC.A.M.I., LLC · SOUTH LIMA, NY, UNITED STATES · built 2000
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeBox
Hull configurationMonohull
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 7 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 2 other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

7 May 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7889512
8 March 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7152404
2 December 2019 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6866778
7 August 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6775897
14 February 2019 Administrative Inspection · DAPI Audit · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6619959
26 July 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6491903
29 January 2018 Administrative Inspection · DAPI Audit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6345896
5 December 2017 COI Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6314507
16 November 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6308506
18 March 2016 DAPI Audit · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5835702

Deficiency record · 10

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) protect passengers, crew, other persons and the vessel from electrical hazard. Vessels masthead light support bracket is broken and masthead light is supported by tape. 46 CFR 183.200 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 2 January 2020
Resolution: Masthead support bracket replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 December 2019 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter. Flexible cords and cables shall not be used for the following: (a) As a substitute for the fixed wiring of a structure. Vessel has extension cord hooked to A/C inverter powering PA system. 46 CFR 183.340 (r)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 2 January 2020
Resolution: Inverter and extention cord removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Overloading
Issued 2 December 2019 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure. Vessel has hydraulic fluid leak on main engine radiator hydraulic fan system leaking into bilge. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 2 January 2020
Resolution: Leak repaired.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 December 2017 Resolved
Schedule company wide DAPI Audit with Sector Honolulu to be conducted IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 18 December 2017
Resolution: Company scheduled DAPI Audit on 23 January 2018 after sister vessel's COI Inspection.
Navigation › Piloting/Steering › Marine Charts
Issued 5 December 2017 Resolved
Provide an updated navigation chart for operating areas. 46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 18 December 2017
Resolution: Received picture of updated navigational charts onboard.
Documentation › Certificates/Documents › Permit, Other
Issued 5 December 2017 Resolved
Provide FCC operator's permit. 46 CFR 184.502; 47 CFR 80
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 7 December 2017
Resolution: Vessel owner provided FCC Operator's permit for vessel captain.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 December 2017 Resolved
Ensure hatch covers are installed with securing devices. 46 CFR 179.360(b)(1) & (2).
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 12 December 2017
Resolution: Received picture of hatch covers installed with securing devices.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 December 2017 Resolved
Vessel restricted to carrying no more than 6 passengers until operational control is lifted for operating without a valid COI due to missing annual and dry dock in March 2017. 46 CFR 176.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Operational control lifted in MISLE.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 November 2017 Resolved
1) Vessel may not operate with greater than six passengers until successful completion of a Certificate of Inspection (COI) and a dry-dock inspection. 46 C.F.R. 176.502
Action required: 705 - Other - as specified
Due 16 December 2017
Resolved 5 December 2017
Resolution: Vessel satisfactorily completed COI Renewal. TCOI issued on 05 December 2017.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 March 2016 Resolved
Provide 3 adult life jackets to meet COI requirements. Passenger count is restricted to 45.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 April 2016
Resolved 6 April 2016

Recorded names · 2

HYDRA TERRA I (2005), NEW AMSTERDAM (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.