Records from 2018 to 2026. Most recent: inspection, 25 February 2026.
Inspection history · 18
25 February 2026
Type not recorded
No type recorded · USCGC JOSEPH GERCZAK (WPC 1126) · USCG Oceania District (CGD-O) · Activity 8315339
6 October 2025
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8249155
29 November 2024
Examination of Repairs · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8041234
22 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7985741
21 June 2023
Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7742237
22 November 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7599557
4 July 2022
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7496282
3 April 2022
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7517354
22 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7232064
23 November 2020
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7092546
8 July 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7007956
2 July 2020
Annual Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6993726
17 September 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7007924
1 July 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6734114
4 April 2019
COI Inspection · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6655485
18 December 2018
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6613772
10 December 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6613770
18 June 2018
Initial Certification · Drydock Exam · Administrative Inspection · Construction Oversight · Deadweight Survey · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6576013
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 October 2025
Resolved
Endorsements on Certificates of Documentation are valid for one 1 year. MI discovered expired COD. Provide documentation of renewal process to MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 3 November 2025
Resolution: Extended due to govt. shutdown.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 October 2025
Resolved
Need to provide current drug consortium third party administrator list of all vessel crew members that are subject to random drug testing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2025
Resolved 14 October 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 October 2025
Resolved
Vessel EPIRBS must be tested monthly and logged. No log entries for EPIRB tests at time of inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 6 October 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 November 2024
Resolved
Identified isolated pitted areas on vessel bottom plate exceeding 25% wastage allowance in the following space:
-No. 5 void space directly below center operating consul on the stbd side adjacent to MSD tank.
Vessel operator must submit plan to affect temporary/permanent repair to USCG within 14 days and make necessary repair within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2025
Resolved 14 January 2025
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 August 2024
Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR part 80. Vessel VHF radio unable to transmit on channel 16. Must make necessary repairs or replace radio to the satisfaction of the USCG Marine Inspector. Must use alternate means of communicating VHF on channel 16 and conduct and log radio checks prior to getting underway with passengers until deficiency is rectified.
Action required: 705 - Other - as specified
Due 22 September 2024
Resolved 11 September 2024
Resolution: Verified installation and tested to satisfaction of USCG.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 August 2024
Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR part 80. Vessel has expired Radio Safety Certificate. Must correct to the satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2024
Resolved 18 November 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 August 2024
Resolved
The Original Certificate of Inspection (COI) must be kept on board vessel in weather tight container readily available for use by crew and display to passengers. Original COI not available during inspection. Must correct to the satisfaction of the USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2024
Resolved 11 September 2024
Resolution: Original document unintentionally destroyed due to weather. Issued another Certficate.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 August 2024
Resolved
The master of the vessel shall ensure that the EPIRB is tested monthly and logged. EPIRB tests were not logged upon review of vessel log books. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 22 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 July 2022
Resolved
Exhaust blower switches must be located outside of any space required to be ventilated by this section, and must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. Exhaust blower is not interlocked with starting switch and provide crew safety training in operation of exhaust blower.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 27 July 2022
Resolution: Exhaust blower is directly connected to battery selector switch with an inline fuse for circuit protection and will stay on until the battery selector switch is secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2022
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Both fwd and aft automatic bilge pump visual indicators did not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 27 July 2022
Resolution: Visual indicators installed and tested sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 July 2022
Resolved
The freeing ports must be located to allow rapid clearing of water in all probable conditions of list and trim. Freeing port hinges are seized not allowing free flow of water to drain.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 28 July 2022
Resolution: Drain flaps are freely movable.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 July 2022
Resolved
A hatch exposed to the weather must be watertight. Gasket material for each of the vessel's deck hatches does not provide a watertight seal and allow ingress of water. Properly renew hatch gaskets to prevent ingress of water and accessible deck plates watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 27 July 2022
Resolution: New seals in place to make the deck access plates watertight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2022
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Need to identify number of lifejackets stored overhead in new location.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 27 July 2022
Resolution: Lifejacket locations are labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 July 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position or perform the duties and functions of a position, required by the vessel's COI. Marine employers may form or otherwise use sponsoring organizations, or may use contractors to conduct the random chemical testing programs. No DAPI onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 27 July 2022
Resolution: Received Company DAPI policy and EAP training material.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 July 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Fuse block is not protected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2022
Resolved 27 July 2022
Resolution: Fuse block is properly covered.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 July 2022
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel did not complete the annual inspection by 4 July 2022. The Anniversary date is 4 April. KIBOU is restricted from operating in a commercial passenger carrying service until a new COI inspection is completed. Submit a written application for inspection to schedule a COI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2022
Resolution: Vessel completed COI Renewal.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 June 2021
Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2021
Resolution: Verified fixed-gas fire extinguisher was serviced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 June 2021
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. The visual and audible alarms were inoperable at the helm. Conduct repairs and show proof of operations to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 23 June 2021
Resolution: Showed proper operation of the visual and audible high water level alarms.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 November 2020
Resolved
A space containing machinery powered by, or fuel tanks for, gasoline must ventilation system must have a ventilation system that complies with this section and consists of at least two natural ventilations supply ducts located at one end of the space and that extend to the lowest part of the space or to the bilge on each side of the space.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2021
Resolved 22 June 2021
Resolution: The fuel space has the proper means of ventilation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 July 2020
Resolved
Exhaust blower switches must be located outside of any space required to be ventilated and must be of the type interlocked with the starting switch and the ignition switch so that the blower are started before the engine starter motor circuit or the engine ignition is energized. The vessel's blowers were found to not be interlocked with starting switch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 8 July 2020
Resolution: All three out board engines have been interlocked with the starting switch and the ignition switch so that the blower is started before the engines.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 July 2020
Resolved
A vessel must carry an adequate and up-to-date Coast Guard Light List. The vessel does not have the Coast Guard Light List on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 8 July 2020
Resolution: Vessel rep provided proof of up-to-date CG Light List.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 2 July 2020
Resolved
Employers are responsible for all the actions of their officals, representatives, and agents in carry out the requirements of this subpart. The vessel operator could not provide a valid drug and alcohol consortium certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2020
Resolved 8 July 2020
Resolution: Vessel rep provided evidence of valid drug and alcohol consortium certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 July 2019
Resolved
Make permanent repairs to the starboard engine prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2019
Resolution: Vessel had a mechanical technician survey the starboard engine. The findings where faulty spark plugs. The company attests in letter that the engine is fully operational and there are no safety hazards.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 4 April 2019
Resolved
Provide proof of having permanent draft/loading marks installed on the hull of the vessel. The limiting draft marks shall be submitted back to Marine Safety Center for approval in accordance letter PO21769 dated March 25, 2019. (Stability, Structures, and Lightship Characteristics)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2020
Resolved 22 June 2021
Resolution: The vessel has permanent draft marks.