Records from 2005 to 2025. Most recent: inspection, 30 May 2025.
Documentation record
Registered dimensions (L × B × D)44.4 ft × 15.8 ft × 6.9 ft
Registered tonnagegross 34 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDAMARISCOTTA BOATS INC · ROCKLAND, ME, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portROCKLAND, ME
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 August 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Regulatory (Subpart C or D), Gross Ton
23 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
30 May 2025
Internal Structural Exam · MTSA Verification · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8105149
11 September 2024
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7999337
7 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7762620
21 March 2023
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7654304
7 March 2023
DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7647102
13 September 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7558226
10 September 2021
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7311453
23 July 2020
Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7014406
30 December 2019
Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880497
22 January 2014
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4791295
1 March 2013
Administration
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4541647
27 August 2012
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4423267
23 February 2012
Administration
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4252052
26 December 2005
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2568650
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 August 2023
Resolved
Found petcock from Racor filters not having either a cap or plug preventers, install either caps and or plugs.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 August 2023
Resolved 23 August 2023
Resolution: Caps and or plugs installed on filter drain assemblies.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
The minimum annual percentage rate for random drug testing shall be 50 percent of covered crewmembers. Prock Marine had a random selection of less than 50 percent for the year 2022.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 March 2023
Resolution: Marine Employer provided proof that they were on track to be in compliance with conducting random tests at 50%.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
Marine employers shall randomly select a sufficient number of covered crewmembers for testing. Prock Marine had crewmembers not included in the pool of tested employees which caused deficiency 01 above.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 March 2023
Resolution: The Marine Employee updated their employee list to include all crewmembers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
Marine Employers must provide a scientifically valid method to randomly select crewmembers so that each covered crewmember shall have an equal chance of being tested each time selections are made. Prock Marine was unable to provide method or provide an appropriate roster of the total number of covered crewmembers also contributing to deficiency 01 above.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 March 2023
Resolution: The Marine Employer provided a scientific means for random selection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
46 CFR 16.500 By March 15 of the year following the collection of the data marine employers must submit the data on the form titled U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form.Prock Marine could not provide the previous year’s (2022) MIS form submission.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2023
Resolved 9 March 2023
Resolution: The Marine Employer is supplied a completed MIS form prior to March 15.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 10 September 2021
Resolved
Repair / replace 01 immersion suit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2021
Resolved 11 September 2021
Resolution: New immersion suit installed on vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2021
Resolved
Failed o-ring on hose connection / replace.
Action required: 10 - Deficiency Rectified
Due 10 September 2021
Resolved 10 September 2021
Resolution: New gasket installed, test sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 September 2021
Resolved
Repair / Replace holed fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2021
Resolved 13 September 2021
Resolution: New hose installed on vessel.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 June 2020
Resolved
Provide means to make watertight door between machinery space and crew accommodation watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 July 2020
Resolution: Dogs repaired and tested sat.