Records from 1991 to 2026. Most recent: inspection, 25 January 2026.
Documentation record
Registered dimensions (L × B × D)59.6 ft × 20.0 ft × 8.4 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS, INC. · HOUMA, LA, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portROCKLAND, ME
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
25 January 2026
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8302225
24 July 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8193670
30 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8148333
6 June 2024
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7901859
12 April 2024
Administrative Inspection · Drydock Extension · Drydock Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7901572
7 August 2023
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7762629
23 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7534965
20 April 2021
Annual Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7178815
5 August 2020
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7024823
25 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6986683
15 February 2019
DAPI Audit · Initial Certification · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6626329
11 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6561500
11 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538136
30 June 2017
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6204063
11 July 2012
Uninspected Other
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4376268
23 February 2012
Administration
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4252057
20 December 2011
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4233125
26 December 2005
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2568650
20 December 1999
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 471214
11 February 1997
Uninspected Towing Vessel
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1359355
6 December 1995
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 212240
20 January 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 668199
14 June 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 131650
31 March 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 81373
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2021
Resolved
Replace damaged hoses on P/S generators as needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 31 August 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021
Resolved
Replace expired eyewash in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 31 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021
Resolved
Provide proper enclosure for electrical outlet in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2021
Resolved 31 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 September 2018
Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) No Call Sign. This vessel is not broadcasting any Call Sign at all.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2018
Resolved 11 October 2018
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 July 2012
Resolved
Proper DOT approved alcohol test kits are not onboard vessel.
Due 11 August 2012
Resolved 14 August 2012
Resolution: Deficiency cleared.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 11 July 2012
Resolved
Proper dayshape for vessel is not onboard.
Due 11 August 2012
Resolved 14 August 2012
Resolution: Dayshape provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 July 2012
Resolved
Vessel is missing CG Light list and Coast Pilot on board.
Due 11 August 2012
Resolved 14 August 2012
Resolution: CG Light List and Coast Pilot on board.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 July 2012
Resolved
Vessel missing Marine Radar that is to RTCM standard as per 33 CFR 164.72.
Action required: 705 - Other - as specified
Due 11 August 2012
Resolved 24 September 2012
Resolution: Deficiency cleared.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Number
Issued 11 July 2012
Resolved
Vessel missing a Type V semiportable fire extinguisher.
Due 11 August 2012
Resolved 14 August 2012
Resolution: Semiportable Type V purchased and mounted in Engine Room.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 11 July 2012
Resolved
Fire detection system currently being installed so was unable to test.
Due 11 August 2012
Resolved 14 August 2012
Resolution: Fire Detection System working properly.
Communications › Alarms/Indicators › General Alarm
Issued 11 July 2012
Resolved
Vessel missing general alarm and signage for alarm in engine room.
Due 11 August 2012
Resolved 14 August 2012
Resolution: General Alarm installed.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 11 July 2012
Resolved
Emergency fire pump is currently being installed and was unable to be tested or run at time of inspection.
Due 11 August 2012
Resolved 14 August 2012
Resolution: Proper fire pump onboard and tested.
Fire Fighting
Issued 11 February 1997
Resolved
PROVIDE AN ADDITIONAL B-I UL OR USCG APPROVED PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Accommodation/Occupational Safety
Issued 11 February 1997
Resolved
Install approved MSD and overboard valve.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Lifesaving
Issued 11 February 1997
Resolved
Renew expired hydrostatic release on EPIRB.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Documentation
Issued 11 February 1997
Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH CHEMICAL TESTING REQUIREMENTS FOR THE MATE.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Lifesaving
Issued 11 February 1997
Resolved
SECURE LIFERAFT TO VESSEL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
Condition: Unknown
Due 12 February 1997
Resolved 3 March 1997
Construction/Loadline
Issued 11 February 1997
Resolved
INSTALL GUARDS OVER COMPRESSOR BELTS, HYDRAULIC PUMP COUPLING AND BILGE PUMP COUPLING.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Engineering
Issued 11 February 1997
Resolved
PROVIDE LAGGING ON THE ENGINE EXHAUST.
Condition: Unknown
Due 12 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 11 February 1997
Resolved
Provide radar endorsement on Master's license or provide a certificate of completion of approved radar observation course.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Fire Fighting
Issued 11 February 1997
Resolved
REPAIR THE SMOKE DETECTOR IN THE BUNK ROOM.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Engineering
Issued 11 February 1997
Resolved
INSTALL GUARDS OVER FUEL TANK SIGHT GLASS.
Condition: Unknown
Due 12 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 11 February 1997
Resolved
PROVIDE DRIP SHIELDS FOR PANELS AND SWITCHBOARDS THROUGHOUT VESSEL.
Condition: Unknown
Due 12 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 11 February 1997
Resolved
MOVE PAINTS TO A METAL PAINT LOCKER.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Construction/Loadline
Issued 11 February 1997
Resolved
MAKE ALL WATERTIGHT DOORS WATERTIGHT. THEY ARE NOT SEATING.
Condition: Unknown
Due 12 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 11 February 1997
Resolved
PROVIDE NONCONDUCTIVE MAT IN FRONT OF THE MAIN SWITCHBOARD.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997
Electrical
Issued 11 February 1997
Resolved
INSTALL BATTERY COVERS ON THE BATTERY BOXES.
Condition: Unknown
Due 12 February 1997
Resolved 19 December 1997