Records from 1981 to 2006. Most recent: inspection, 10 January 2006.
Inspection history · 44
10 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2564100
8 September 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2190138
13 August 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2165308
30 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979463
27 September 2000
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 822446
14 September 2000
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 824782
20 March 2000
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1050038
17 March 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 809466
29 May 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436088
27 April 1998
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1123765
2 September 1997
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1402517
17 February 1997
Deficiency Check · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1400501
29 April 1996
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080153
19 January 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078695
8 October 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 146485
5 April 1995
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 839517
17 March 1995
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1162713
9 February 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1149366
8 December 1994
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 865934
23 June 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158630
22 June 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158633
7 April 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 645042
24 September 1992
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1261046
13 July 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 946826
13 July 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 957404
25 November 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1453968
18 November 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 946792
5 May 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 137092
5 May 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 357482
31 March 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 81373
21 December 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1220238
17 August 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1230635
7 July 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1232658
3 July 1990
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1223314
17 June 1990
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1221806
11 September 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1003945
11 September 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1017569
11 September 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1017572
11 September 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1313055
17 September 1986
Credit Drydock
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1310275
12 June 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1306642
5 June 1986
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1306637
24 October 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 976589
18 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271674
Lifesaving
Issued 17 March 1999
No resolution recorded
Conduct Fire and Boat drill to the satisfaction of the attending marine inpsector, to be completed prior to vessel activation, and no later than 01DEC 99.
Condition: Unknown
Due 1 December 2001 — due date passed with no resolution recorded
Lifesaving
Issued 29 May 1998
Resolved
Using good marine practice, effect permanent repairs to the deck gratings in the lower port storage room.
Condition: Unknown
Due 29 May 1998
Resolved 22 June 1998
Electrical
Issued 17 February 1997
Resolved
REMOVE OR DEAD END LOOSE WIRING IN AIR CONDITIONING ROOM.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Documentation
Issued 17 February 1997
Resolved
PROVIDE WASTE MANAGEMENT PLAN AND PLACARD 1AW 33 CFR 151.57 - 151.59.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Fire Fighting
Issued 17 February 1997
Resolved
PROVIDE SPANNER WRENCHES AT EACH FIRE STATION.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Documentation
Issued 17 February 1997
Resolved
PROVIDE EVIDENCE REQUIRED CREW IS IN COMPLIANCE WITH CHEMICAL TESTING REGULATIONS OF 46 CFR PART 16.
Condition: Unknown
Due 17 February 1997
Resolved 17 February 1997
Lifesaving
Issued 17 February 1997
Resolved
RENEW OR REPLACE RETRO REFLECTIVE TAPE ON RING BUOYS WHERE MISSING.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Documentation
Issued 17 February 1997
Resolved
PROVIDE LETTER DESIGNATING PERSON IN CHARGE.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REMOVE OLD WIRING NOT IN USE FOLLOWING REMOVAL OF OLD GYRO COMPARTMENT UNDER CONTROL ROOM.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Fire Fighting
Issued 17 February 1997
Resolved
MOUNT B2 PORTABLE FIRE EXTINGUISHER AT ENTRANCE TO PAINT LOCKER 2ND DECK.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Accommodation/Occupational Safety
Issued 17 February 1997
Resolved
REMOVE SHACLE AND CHAIN HOLDING DOOR IN AFT CABIN AREA LOCKED CLOSED. DOOR LOCATED IN AFT MACHINE SHOP BY SINK.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Construction/Loadline
Issued 17 February 1997
Resolved
FREE UP DOGS ON WATERTIGHT DOOR BETWEEN ENGINE ROOM AND GENERATOR ROOM. PERMANENTLY REPAIR LOWER DOORS ON PORT AND STRB LOWER ENGINE ROOM. (CARRY OVER FROM ITEM #6 ISSUED 19JAN96).
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
DEMONSTRATE PROPER OPERATION OF WEATHER DECK AUX GENERATOR AND RELATED SAFETY DEVICES INCLUDING BUT NOT LIMITED TO LOW LUBE OIL PRESSURE SHUTDOWN,HIGH WATER TEMPERATURE ALARM AND PVERSPEED TRIP.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPAIR NUMEROUS OIL LEAKS ON AUX GENERATOR INCLUDING BUT NOT LIMITED TO_x001C_ OIL FILTER, VALVE COVER AND HAND HOLE COVERS.
Condition: Unknown
Due 7 March 1997
Resolved 27 February 1997
Lifesaving
Issued 17 February 1997
Resolved
LABEL LIFE JACKET STORAGE BOX.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Lifesaving
Issued 17 February 1997
Resolved
PROVIDE 15 ADULT PFD'S WITH LIGHTS.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPLACE BROKEN LIGHT FIXTURE GLOBE IN DREDGE PUMP COMPARTMENT, PORT SIDE.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Lifesaving
Issued 17 February 1997
Resolved
PROPERLY SECURE AIR PRESSURE HOSE TO MOUNTING BRACKETS LOCATED DREDGE PUMP COMPARTMENT.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPLACE MISSING OR DETERIATED HOSE CLAMPS ON EMERGENCY GENERATORS WATER INTAKE MANIFOLD.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPLACE ALL PLASTIC WIRE TIES SUPPORTING ELECTRIC WIRES RUNNING THROUGH OUTTHE VESSEL WITH METAL HOLDERS.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
DEMONSTRATE PARALLEL OPERATION OF S/S GENERATORS AND REVERSE POWER PROTECTION RELAYS.
Condition: Unknown
Due 14 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPLACE AND PROVE PROPER OPERATION OF REMOTE ENGINE SHUTDOWNS FOR BOTH MAINPUMP ENGINES AND S/S GENERATOR.
Condition: Unknown
Due 14 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPLACE MISSING ELECTRICAL COVER ON STBD MAIN PUMP ENGINE EXHAUST TEMPERATURE SENSOR.
Condition: Unknown
Due 14 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPAIR/REPLACE AND PROVE PROPER OPERATION OF AUX GENERATOR LUBE OIL SHUTDOWN AND ALARM.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPAIR/REPLACE AND PROVE PROPER OPERATION OF AUX GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
RENEW ELECTRICAL PANEL LATCHES WHERE BROKEN OR MISSING IN AIR CONDITIONING ROOM.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Lifesaving
Issued 17 February 1997
Resolved
REMOVE EXCESSIVE OIL FROM ENGINE ROOM AND GENERATOR ROOM BILGES. PROVIDE RECEIPT FOR PROPER DISPOSAL.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
INSTALL BLANKS IN ELECTRICAL PANEL WHERE MISSING. (COMPT. UNDER CONTROL ROOM) AND ENGINE ROOM WHERE MISSING.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 17 February 1997
Resolved
REPAIR AND PROVE PROPER OPERATION OF EMERGENCY LIGHT PORT SIDE UPPER ENGINEROOM.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Lifesaving
Issued 17 February 1997
Resolved
REPLACE RELIEF VALVES ON FORWARD AIR RECEIVER FOR HAULING GEAR WITH 125 PSIMAXIMUM RELIEF VALVES OR LESS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 17 February 1997
Resolved 17 February 1997
Fire Fighting
Issued 17 February 1997
Resolved
COMPLETE EMERGENCY DRILLS WITH REQUIRED CREW TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 17 February 1997
Resolved 17 February 1997
Construction/Loadline
Issued 17 February 1997
Resolved
FREE UP DOGS ON ALL MAIN DECK WEATHER TIGHT HATCHES AND PROVIDE DOGGING WRENCHES AT EACH DOOR.
Condition: Unknown
Due 7 March 1997
Resolved 25 February 1997
Electrical
Issued 19 January 1996
Resolved
INSTALL LIGHT FIXTURE COVERS IN LAUNDRY ROOM AND AFT CREW BERTH.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Electrical
Issued 19 January 1996
Resolved
INSTALL COVER ON JUNCTION BOX IN LAUNDRY ROOM.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Construction/Loadline
Issued 19 January 1996
Resolved
FREE UP DOGS ON ALL MAIN DECK WATER TIGHT DOORS.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Engineering
Issued 19 January 1996
Resolved
INSULATE EXHAUST LINES ON SMALL GENERATOR FROM THE MANIFOLD TO GRATING.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Engineering
Issued 19 January 1996
Resolved
REPAIR RAW WATER LINE ON SMALL GENERATOR IN WAY OF THE SOFT PATCH.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Construction/Loadline
Issued 19 January 1996
Resolved
FREE UP DOGS ON 2 WATER TIGHT DOORS BETWEEN ENGINE ROOM AND PUMP ROOM. PERMANENTLY REPAIR LOWER DOOR FRAME ON PORT DOOR.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Accommodation/Occupational Safety
Issued 19 January 1996
Resolved
REPAIR CRACKED WINDOWS IN WHEEL HOUSE, OFFICE AND CREW BERTHING.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Lifesaving
Issued 8 December 1994
Resolved
PRIOR TO MANNING VESSEL BEYOND SIX PERSONS THE ADEQUATE NUMBER OF PFD'S WILL BE PLACED ON BOARD.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Fire Fighting
Issued 8 December 1994
Resolved
PRIOR TO DEPARTING FOR INTERNATIONAL WATERS, BARGE WILL MEET REQUIREMENTS OF 46 CFR 96.35 TO THE SATISFACTION OF LOCAL OCMI.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Lifesaving
Issued 8 December 1994
Resolved
PROVIDE ABS DOCUMENTATION TO THE SUITABILITY OF BARGES PAINT LOCKER, NLT 08JAN95 TO THE SATISFACTION OF THE OCMI.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Engineering
Issued 8 December 1994
Resolved
DEMONSTRATE TO COAST GUARD INSPECTOR THE ACCURACY OF MACHINARY GAUGES IN CONTROL BOOTH NOT LATER THAN 08JAN95.
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Unknown
Issued 22 June 1993
Resolved
PROVIDE PROOF OF ENROLLMENT IN LOCAL CHEMICAL TESTING PROGRAM AS PER 46 CFR16. MAIL OR FAX PROOF OF COMPLIANCE NO LATER THAN 3 JULY 1993.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Unknown
Issued 22 June 1993
Resolved
PROVIDE COPY OF DESIGNATED PERSON IN CHARGE. BRING COPY TO OFFICE OR FAX PROOF OF COMPLIANCE NO LATER THAN 3 JULY 1993.
Condition: Unknown
Due 30 August 1993
Resolved 30 August 1993
Accommodation/Occupational Safety
Issued 24 September 1992
Resolved
PROVIDE COAST GUARD APPROVED INSTALLATION PLAN FOR THE 8-MAN BERTHING TRAILER INSTALLED ON THE 02 LEVEL PORT SIDE.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Accommodation/Occupational Safety
Issued 24 September 1992
Resolved
PROVIDE PROOF THAT INSTALLATION OF 8-MAN BERTHING TRAILER ON THE 02 LEVEL HAS NOT AFFECTED VESSEL'S STABILITY, OTHERWISE, OBTAIN A NEW STABILITY LETTER WITH THE 8-MAN BERTHING TRAILER CONSIDERED IN THE CALCULATIONS.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Documentation
Issued 24 September 1992
Resolved
IN CONJUNCTION WITH REQUIREMENTS D1 AND D2, ISSUANCE OF NEW STABILITY LETTER VOIDS VESSEL'S CURRENT LOADLINE CERTIFICATE. OBTAIN NEW LOADLINE CERTIFICATE.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Documentation
Issued 24 September 1992
Resolved
PROVIDE COAST GUARD APPROVED PLAN CONCERNING INSTALLATION OF APPROXIMATELY 8400 LBS. OF STEE IN THE AFT EXTREMITY OF THE VESSEL. FURTHERMORE, PROVIDE PROOF THAT ADDITION OF THEIS WEIGHT DOES NOT AFFECT VESSEL'S STABILITY AND LOADLINE.
Condition: Unknown
Due 10 February 1993
Resolved 10 February 1993
Navigation
Issued 13 July 1992
Resolved
Replace the No.one Filament or Bulb for the Sternlight.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Lifesaving
Issued 13 July 1992
Resolved
Provide one waterlight in operating condition for fwd/bridge life-ring.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Fire Fighting
Issued 13 July 1992
Resolved
Stencil vessel name on all firehoses(9).
Condition: Unknown
Due 23 July 1992
Resolved 17 July 1992
Navigation
Issued 13 July 1992
Resolved
Replace both Filiments or Bulbs for Port Sidelight.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Fire Fighting
Issued 13 July 1992
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 23 July 1992
Resolved 17 July 1992
Navigation
Issued 13 July 1992
Resolved
Provide a current FCC Safety Safety Certificate.
Condition: Unknown
Due 17 July 1992
Resolved 17 July 1992
Lifesaving
Issued 13 July 1992
Resolved
Stencil PFD Storage Box with No. PFD"s.
Condition: Unknown
Due 23 July 1992
Resolved 17 July 1992
Fire Fighting
Issued 25 November 1991
Resolved
Fire control plan missing.
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Construction/Loadline
Issued 25 November 1991
Resolved
Demonstrate ability to dewater voids.
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Engineering
Issued 25 November 1991
Resolved
air recievers pressure relief valves on #4 and #6 failed to lift.
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Navigation
Issued 25 November 1991
Resolved
Ssignals to indicate refueling missing
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Engineering
Issued 25 November 1991
Resolved
Demonstrate proper operation emergency fuel shut-offs.
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Electrical
Issued 25 November 1991
Resolved
rewire eliminating wire nuts command module for main engines.
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Engineering
Issued 25 November 1991
Resolved
Containment for fueling station missing
Condition: Unknown
Due 25 November 1991
Resolved 25 November 1991
Unknown
Issued 5 May 1991
Resolved
DURING DREDGING OPERATIONS VESSEL OPERATORS DISCHARGED GARBAGE INTO THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Fire Fighting
Issued 3 July 1990
Resolved
PROVIDE PAINT LOCKER ON VESSEL FITTED WITH A FIXED EXTINGUISHING SYSTEM. SUBMIT TO MARINE SAFETY OFFICE PLANS FOR INSTALLATION PRIOR TO INSTALLATION
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Fire Fighting
Issued 3 July 1990
Resolved
PROVIDE TWO FIREMEN'S OUTFITS AS PER 46CFR 96.35-10 (EXISTING REQUIREMENT D2 DATED 11SEP87 BY MSO BALTIMORE)
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Fire Fighting
Issued 3 July 1990
Resolved
UPDATE AND DISPLAY FIRE & SAFETY PLAN AS PER 46CFR 97.36-11 (EXISTING RE- QUIREMENT D1 DATED 11SEP87 BY MSO BALTIMORE)
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Documentation
Issued 3 July 1990
Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE ON VESSEL
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Documentation
Issued 3 July 1990
Resolved
SUBMIT LTR TO MSO BALTO CERTIFICATE THAT COMPANY HAS INSTITUTED DRUG URINALYSIS TESTING PROGRAM
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Lifesaving
Issued 3 July 1990
Resolved
STENCIL NUMBER OF PERSONS ON STARBOARD LIFERAFT
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Deck/Cargo
Issued 3 July 1990
Resolved
PROVIDE PROPER CONTAINMENT FOR FEUL OIL TRANSFER STATION (33CFR)
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Documentation
Issued 3 July 1990
Resolved
PROVIDE LETTER DESIGNATING PERSON IN CHARGE OF FUEL TRANSFER OPS
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Electrical
Issued 3 July 1990
Resolved
REMOVE DEAD-END WIRES NEAR #1 FIRE PUMP
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Unknown
Issued 11 September 1987
Resolved
UPDATE AND DISPLAY FIRE & SAFETY PLAN AS PER 46CFR97.36-1.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Unknown
Issued 11 September 1987
Resolved
PROVIDE TWO FIREMANS OUTFITS AS PER 46CFR96.35-10.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Unknown
Issued 11 September 1987
Resolved
UPDATE AND DISPLAY FIRE & SAFETY PLAN AS PER 46CFR97.36-1.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Unknown
Issued 11 September 1987
Resolved
PROVIDE TWO FIREMAN'S OUTFITS AS PER 46CFR96.35-10.
Condition: Unknown
Due 11 September 1987
Resolved 11 September 1987
Unknown
Issued 5 June 1986
Resolved
MAKE AVAILABLE INTERNAL INSPECTION OF ALL SEVEN (7) AIR RECEIVERS. MUST MEET THE SATISFACTION OF THE COGNIZANT [name withheld] 05JUL86.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986