MAURY USCG vessel records
← All vessels

CHARGER

Built
1977
Last inspected
7 April 2023
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 April 2023
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7717690
WDM5630
153800
Flag
UNITED STATES
Maury page id
psix-153800

Documentation record

Tonnage as PSIX records it297 - Regulatory (Subpart C or D), Gross Ton
911 - Convention (Subpart B), Gross Ton
201 - Regulatory (Subpart C or D), Net Ton
273 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 7 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

7 April 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7664833
16 May 2022 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7451534
12 March 2018 Administrative Inspection · Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6371232
2 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6364626
1 March 2017 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6096813
31 January 2017 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6081180
19 February 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5823948

Deficiency record · 17

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2023 Resolved
Each replaceable power source for a personal flotation device light must be replaced on or before its expiration date and the light must be replaced when it is no longer serviceable. 03 Life jacket lights must be replaced.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2023
Resolution: Verified lifejacket lights operable.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 15 June 2023 Resolved
Separate sleeping accommodations are to be provided for the deck, engine, and steward groups of the crew. Vessel did not have sufficient amount of mattresses for manning levels. Rectify prior to carriage of personnel in addition to crew.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2023
Resolved 22 August 2023
Resolution: Verified all mattresses on board were approved mattresses and the appropriate amount on board for the required personnel.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 June 2023 Resolved
All vessels must carry adequate and up to date coast pilots, light lists, notices to mariners, tide tables, current tables and all other publications necessary. Vessel was not able to provide charts and publications.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2023
Resolution: Verified proper publications onboard on computer and paper copies available.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 15 June 2023 Resolved
Vessels operated more than 200 nautical miles from the nearest land must be equipped with an MF–DSC radiotelephone transmitter and receiver meeting the requirements of paragraph (a)(2) of this section. Vessel was not equipped with MF-DSC capabilities.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2023
Resolution: Verified proper installation onboard vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 June 2023 Resolved
All vessels shall have efficient guard rails or bulwarks on decks and bridges. The height of rails or bulwarks shall be at least 39 inches from the deck. At exposed peripheries of the freeboard and superstructure decks, the rails shall be in at least three courses, including the top. The opening below the lowest course shall not be more than 9 inches. The courses shall not be more than 15 inches apart. Vessel did not have proper rails and spacing.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2023
Resolution: Verified proper rail installation.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 June 2023 Resolved
Vessel did not have adequate automation test procedures. Vessel must have automation procedures to meet NVIC 01-78. Vessel must have means to monitor high gear oil temperature.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2023
Resolved 22 August 2023
Resolution: Vessel installed new sensor to monitor high gear oil temp. Verified automation test procedures meet requirements of NVIC 01-78.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 March 2018 Resolved
Additional emergency light fixture needed IVO forward engineroom door.
Action required: 705 - Other - as specified
Due 12 April 2018
Resolved 27 June 2018
Resolution: Installed new light
Electrical › Lighting (emergency) › Lighting Fixture
Issued 13 March 2018 Resolved
Pilothouse passageway and aft auxilary machinery passageway emergency light was inoperable.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 27 June 2018
Resolution: E-Light installed.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 13 March 2018 Resolved
Injector line on Stbd generator was worn IVO a loose hanger.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 27 June 2018
Resolution: Injector line replaced.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 13 March 2018 Resolved
Port and Stbd Aft main deck ladders were wasted IVO upper supports. Vessel to repair and weld supports.
Action required: 705 - Other - as specified
Due 13 April 2018
Resolved 27 June 2018
Resolution: Ladders supports were welded.
Communications › Audible Communications › Electronic Deep-sea Sounding Apparatus
Issued 1 March 2017 Resolved
Comms from the Eng room and E-steering to the bridge not working.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2017
Resolution: Repaired connections to comms.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 1 March 2017 Resolved
Rudder angle indicator in E steering inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2017
Resolution: 3rd party repaired malfunctioning indicator.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 1 March 2017 Resolved
Port main shutdowns from the operating station inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2017
Resolution: 3rd party repaired electrical component that caused issue.
Fire Fighting › Fire Pumps › Suction Valve
Issued 1 March 2017 Resolved
Fire pump not working properly only 20 psi.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2017
Resolution: Pump had debris inside. Debris was removed and pump working fine at 75 psi.
Construction/Loadline › Structures › Superstructure
Issued 19 February 2016 Resolved
Aft control station shack had a damaged glass window.
Condition: Damaged By Earlier Event
Due 4 March 2016
Resolved 13 March 2018
Resolution: Repaired
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 February 2016 Resolved
A/C junction boxes on aft pilothouse bulkhead were wasted exposing wires.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2016
Resolved 13 March 2018
Resolution: Replaced.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 February 2016 Resolved
Emergency lighting required at embarkation station IAW 46 CFR 112-15-1(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 March 2016
Resolved 13 March 2018
Resolution: Installed.

Recorded names · 1

MISS ELIZABETH (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.