Records from 1992 to 2026. Most recent: inspection, 26 February 2026.
Inspection history · 30
26 February 2026
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8317113
26 February 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8084853
22 February 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7868760
2 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7679211
1 May 2023
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7684751
14 March 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7651622
1 March 2023
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7645011
24 February 2023
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7641646
17 February 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7638401
6 November 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7595028
29 September 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7599060
8 November 2021
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7347378
1 February 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7134046
3 February 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5063217
22 June 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5059865
28 January 2013
Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4523745
14 June 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4344084
14 June 2012
Administration
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4344892
31 May 2011
Marine Casualty Follow Up
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4030175
29 May 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4028529
25 April 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3996519
10 March 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3696338
25 April 2007
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2915628
20 April 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2919271
28 July 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1655806
28 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 666536
18 December 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 31147
17 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666535
24 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 73243
25 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 13658
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 February 2026
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space.
STBD generator observed with a fuel leak near fuel supply hose.
Vessel shall enact permanent repairs to the satisfaction of the Coast Guard and submit report attesting to the satisfactory repair to [email withheld].
46 CFR 143.220(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2026
Resolution: Received video of the stbd generator running for 2 minutes with no F/O leak.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must: (1) Be maintained to ensure proper
operation.
STBD and Port shaft seals were observed leaking at high rate.
Vessel shall enact permanent repairs to the satisfaction of the Coast Guard and submit report attesting to the satisfactory repair to [email withheld].
46 CFR 143.205(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2026
Resolution: Received video of both port and stbd shafts truning for over a minute with no leaks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026
Resolved
Pressure vessels must be externally examined annually. Relief valves must be tested in accordance with §143.245. (c) All pressure vessels must have the MAWP indicated by a stamp, nameplate, or other means visible to the crew.
Relief valves was the original and hasn't been tested. Additionally, the pressure vessel had no MAWP marking.
Vessel shall enact permanent repairs to the satisfaction of the Coast Guard and submit report attesting to the satisfactory repair to [email withheld].
46 CFR 143.300 (b)/(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2026
Resolution: Received pictures of MAWP on air receiver and new compressor and receiver relief valves installed with proof of their relief psi.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 February 2026
No resolution recorded
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and emergency conditions.
Both steering hydraulic ram pivot pins were observed worn and moving excessively at their connection point.
Vessel shall enact permanent repairs to the satisfaction of the Coast Guard at next dry dock.
Action required: 705 - Other - as specified
08 - Alarms › N/A - No Subsystem › General alarm
Issued 26 February 2025
Resolved
Each towing vessel must be fitted with a general alarm that has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light that is identified with a sign that reads: " Attention General Alarm - When Alarm Sounds or Flashes Go to Your Station".
Marine Inspector identified an inoperable engine room general alarm light.
Replace the light prior to movement.
46 CFR 143.400
60c
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 March 2025
Resolved 28 February 2025
Resolution: Vessel provided video evidence of engine room general alarm light fuctional upon activation of general alarm.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 February 2025
Resolved
AIS must be maintained in effective operating condition, which includes the accurate input and upkeep of all AIS data fields and system updates.
Marine Inspector identified the AIS was broadcasting the vessel's previous name.
Rectify the vessel's identifying information in AIS pri
or to movement.
46 CFR 164.46
60c
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 March 2025
Resolved 28 February 2025
Resolution: Verified vessel info has been updated in AIS.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2025
Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet.
Marine Inspector identified the FCC document is still displaying the vessel's previous name.
Rectify the vessel's identifying information in AIS pri
or to movement.
47 CFR 80.13
60c
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 March 2025
Resolved 28 February 2025
Resolution: Vessel submitted FCC document with updated effective and expiration dates. See attached document.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 February 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Marine Inspector observed batteries missing their box covers in the center of the engine room.
Fit the batteries with box covers within 30 days.
46 CFR 143.400
50c
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2025
Resolved 26 February 2026
Resolution: During Annual Exam observed batteries cover in place.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2025
Resolved
Each vessel fitted with installed bulwarks around the exterior of the main deck must have sufficient freeing ports or scuppers or a combination of freeing ports and scuppers to allow water to run off the deck quickly without adversely affecting the stability of the vessel.
Marine Inspector identified old AC drain line penetrating deck house on the starboard.
Remove the drain line and seal the penetration.
46 CFR 144.320
16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 26 February 2026
Resolution: Company provided pictures of corrected penetration.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 February 2025
No resolution recorded
The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed.
Marine Inspector identified wastage and cracking along the main engine room transverse beam.
Rectify the cracking and wastage by the next drydock.
46 CFR 144.200
705c
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 March 2025 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2024
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact.
Battery installations in the engine room have wire nuts and improper connections.
Make permanent repairs to the satisfaction of a USCG Marine Inspector.
46 CFR 143.400(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 19 March 2024
Resolution: Batteries were re-wired satisfactorily.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2024
Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments.
Battery boxes in engine room have standing water inside.
Remove water, dry and secure the battery box enclosures to the satisfaction of a USCG Marine Inspector.
46 CFR 143.400(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 19 March 2024
Resolution: Battery boxes were drained of water.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 February 2024
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
Power cable for vessel’s dryer is damaged and has improper repair with electrical tape.
Make permanent repairs to the satisfaction of a USCG Marine Inspector.
46 CFR 143.400(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 19 March 2024
Resolution: Dryer power cable was satisfactorily repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 27 February 2024
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components.
Exhaust manifold on both port and starboard generators have no insulation.
Install insulation to the satisfaction of a USCG Marine Inspector.
46 CFR 143.220(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 19 March 2024
Resolution: Both MDE exhaust manifolds were fitted with adequate insulation.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 February 2024
Resolved
Each life float and rigid buoyant apparatus must be fitted with a lifeline, pendants, a painter, and floating electric water light approved under approval series 161.010.
The installed rigid buoyant apparatus has no floating electrical water light attached.
Install an approved floating electric water light to the satisfaction of a USCG Marine Inspector.
46 CFR 143.325(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2024
Resolved 19 March 2024
Resolution: Floating electric water light was affixed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 February 2024
Resolved
Except as required by §§ 140.900 and 140.905, records do not need to be filed with the Coast Guard, but must be kept available for review by the Coast Guard upon request. Records, unless required to be maintained for a longer period by statute or other federal regulation, must be retained for at least 1 year after the date of the latest entry.
Vessel is not retaining required records of health and safety training, and inspections of all towing gear so as to be readily available for review by the Coast Guard.
Retain all required Towing Vessel Records for a minimum period of one year.
46 CFR 140.910(d)
Action required: 705 - Other - as specified
Due 27 February 2025
Resolved 26 February 2026
Resolution: Reviewed records. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 2 March 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing and safety of persons onboard. Vessel has placed a portable generator on the bow of the vessel to replace the STBD generator that is inoperable. Temporary generator is not designed to provide safe operation of the vessel and safety of personnel. Remove portalbe generator and restore the vessel's STBD generator to original design and to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2023
Resolution: Portable generator removed and STBD generator repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 March 2023
Resolved
Installed electrical power source(s) must be capable of carrying the electrical load of the towing vessel under normal operating conditions. The starboard generator is not operational. Repair to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2023
Resolution: STBD generator repaired.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 March 2023
Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a generator prime mover. The fuel shutoff valve for the port generator prime mover has a missing remote means of closure and can only be secured locally. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2023
Resolution: Remote fuel shutoff valve has been repaired and is functional.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 March 2023
Resolved
Propulsion machinery, including shafting, must: be maintained to ensure proper operation. The three drive shaft packing glands are leaking water in a steady stream. Repair to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2023
Resolution: Propulsion machinery shafting packing glands have been repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 March 2023
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The operating station gauges for monitoring auxiliary generator engine water temperature and oil pressure are inoperable. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 12 April 2023
Resolution: Operating station gauges for water temp and oil pressure have been repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 February 2023
Resolved
Electrical systems and equipment must function properly and minimize shock hazards. There is no nonconductive matting at the main switchboard. Repair or replace to the satisfaction of the attending USCG Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Nonconductive matting has been installed at switchboard.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 8 November 2021
Resolved
Each towing vessel must be fitted with a general alarm that: has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light.
Vessel did not have flashing red light located in engine room for general alarm system.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 30 November 2021
Resolved 17 November 2021
Resolution: Recieved photo documentation of installation of light in E/R.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 November 2021
Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of 141.370 for specified areas where the vessel operates.
Visual distress signals were not on-board the vessel.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 30 November 2021
Resolved 17 November 2021
Resolution: Accepted photo documentation of installation of flares/smoke in wheelhouse.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2021
Resolved
A portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230 (b) of this part.
Portable fire extinguisher was not located on or near flammable storage cabinet.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 30 November 2021
Resolved 17 November 2021
Resolution: Accepted photo documentation of installation of fire extinguisher adjacent to flammable storage cabinet.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2021
Resolved
Non conductive mats or grating must be provided on the deck in front of each switchboard and, if it is accessible from the rear, on the deck behind the switchboard.
Vessel did not have noncondutive matting in front of switchboards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2021
Resolved 17 November 2021
Resolution: Accepted photo documentation of installation of electrical matting.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 25 April 2007
Resolved
Vessel had no lifejackets on board.
Action required: 705 - Other - as specified
Due 25 April 2007
Resolved 25 April 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 20 April 2007
Resolved
Master of vessel was not licensed for towing vessel operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2007
Resolved
Stern Light not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2007
Resolved
Ring Buoy in disrepair.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 April 2007
Resolved
Vessel did not have an installed remote fuel shutodwn IAW 46 CFR 27.230
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 20 April 2007
Resolved
Vessel did not have an installed fixed or portable fire pump IAW 46 CFR 27.301
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2007