Records from 2020 to 2026. Most recent: inspection, 26 June 2026.
Inspection history · 30
26 June 2026
Deficiency Check · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8410466
8 June 2026
PSC B · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8392651
16 December 2025
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8284068
12 December 2025
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8278671
27 February 2025
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8083124
26 September 2024
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8010013
20 August 2024
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7981719
22 January 2024
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7849664
17 April 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7665651
27 March 2023
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7657956
26 March 2023
PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7656971
26 March 2023
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7658043
28 January 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7624376
27 December 2022
Deficiency Check · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7612047
5 December 2022
Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7604688
4 May 2022
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7441108
13 September 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7311262
14 May 2021
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7192088
21 December 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7114602
25 September 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7065145
8 September 2020
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7053263
26 August 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7043392
19 August 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7037525
13 May 2020
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6952517
11 May 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6951542
24 April 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6943377
7 April 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6936557
29 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6932869
26 March 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6931964
24 March 2020
PSC A
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6930906
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2026
Resolved
In order to achieve the fire safety set out in paragraph 1, the following functional requirements are...minimization of possibility of ignition. PSCO observed 02 holdback devices on fuel tanks in the purifier room and upper engine room.
74 SOLAS (cons) 2004 II-2/2.1.8
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2026
Resolved 26 June 2026
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 26 June 2026
Resolved
The function of... fire detection shall be periodically tested.. by means of equipment producing hot air at the appropriate temperature. PSCO observed heat detector testing device not operational.
74 SOLAS (cons) 2004 II-2/ 7.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 June 2026
Resolved 29 June 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 June 2026
Resolved
The following functional shall be met, fire protection systems...shall be maintained and ready for use. PSCO observed 01 system fault on fire control panel for zone 13 "Forward".
74 SOLAS (Cons) 2004 II-2/ 14.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2026
Resolved 26 June 2026
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 8 June 2026
Resolved
The company should ensure that all personnel involved in the company's safety management system have an adequate understanding of relevant rules, regulations. codes and guidelines.
During PSC exam, PSCO witnessed multiple safety violations and inoperable safety equipment as documented in the objective evidence below. USCG PSCO recommends an external audit of the vessel’s Safety Management System be completed within 14 days and verification of completion submitted to the USCG.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2026
Resolved 16 June 2026
Resolution: external audit of the vessel’s Safety Management System was completed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 June 2026
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with... fire protection systems and fire fighting protections shall be maintained ready for use. PCSO observed 04 fire detectors in the engine room were not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2026
Resolved 12 June 2026
Resolution: RINA surveyor tested the fire detectors in zone 4 and tested satisfactory
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 8 June 2026
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in these divisions. PSCO observed 01 hold back on the purifier room door.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2026
Resolved 12 June 2026
Resolution: All hold backs were removed
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 8 June 2026
Resolved
The purpose of this regulation is to maintain effectiveness of the fire safety measures the ship is provided with. the following functional requirements shall be met: Fire protection systems and appliances shall be maintained ready for use. PSCO observed 02 system "General Fault's" on the fire control panel in the engine control room for zone L10.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2026
Resolved 12 June 2026
Resolution: The fualt was cuased by a bad connection between the bases and heads of three detectors. The fualt was fixed and the surveyor witnessed the panel showing no further fualts on loop 10 of the panel
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 June 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat mechanical steering was found inoperable when PSCO requested ship’s crew to test. PSCO observed an active leak of hydraulic fluid from the lifeboat’s mechanical steering gear.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2026
Resolved 12 June 2026
Resolution: The vesssel overhualed the steering gear and fixed the hydralic leak and the steering tested satisfactory with no further leaks.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 June 2026
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage tank having a capacity of 500 L... shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. PSCO observed the valve not in the closed position after pulling the line.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2026
Resolved 12 June 2026
Resolution: The quick closing valve for the engine room and for the emergency generator were tested to be satisfactory
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 June 2026
Resolved
In order to achieve the fire safety objective sat out in paragraph 1... the restricted use of combustible material. PSCO observed unsecured hazmat and combustible liquids stored under the fuel tank in the purifier room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2026
Resolved 12 June 2026
Resolution: All hazmat and combustible materials were removed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 December 2025
Resolved
The administration may exempt from paragraphs 7.1.3 and 7.2 cargo spaces. Solely intended for carriage of cargoes that constitute a low fire risk. When such exemptions are granted the administration shall issue a certificate.
PSCO observed no exemption certificate.
74 SOLAS (09) II-2/ 10.7.1.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 23 December 2025
Resolution: Received exemption certificate.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 12 December 2025
Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In considering the design of such eqiupment and approvals, the admin shall have regard to the specification recommended by the organization.
PSCO observed crew members unable to provide OWS history on oil content meter.
MARPOL 1/14.7
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2025
Resolved 16 December 2025
Resolution: Vessel provided video evidence of crew members recovering OWS usage data from their OCM.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 August 2024
Resolved
Before the ship leaves port and at all times during the voyage, all LSA shall br in working oder and ready for immediate use. PSCO observed a significant lube oil discharge during operational test of the rescue boat engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2024
Resolution: Rescue boat engine was repaired by crew, stopping the abnormal lube oil discarge, tested and found to be satisfactory.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Operational procedures for engines or equipment
Issued 20 August 2024
Resolved
The attained annual operation CII shall be documented and verified against the required annaul operational CII to determine operational carbon intensity rating. The vessel was unable to provide an annual operational carbon intensity rating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2024
Resolved 26 September 2024
Resolution: Received Flag excemption letter on behalf on Panama for MARPOL VI/28.1. Routed to district for review. Flag excemption letter deemed valid by Office of Commercial Vessel Compliance.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 March 2023
Resolved
1509 - Maintenance of the ship and equipment
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations, and with any additional requirements which may be established by the company. Due to the objective evidence detailed in the below deficiencies, the vessel is not in substantial compliance with the relevant conventions, calling into question the adequacy and implementation of the vessel's SMS under the ISM code. Furthermore, PSCO observed objective evidence that the SMS requirements for maintenance of life saving equipment and fire fighting equipment were not being adhered to. An external audit conducted by Flag or RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port.
74 SOLAS(20) IX/3.1 ISM Code A/10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 27 March 2023
Resolved 28 March 2023
Resolution: RINA Class Surveyor conducted ISM Audit into maintenance and inspection of lifesaving and firefighting equipment.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 March 2023
Resolved
11104 - Rescue Boats
The condition of the ship and its equipment shall be maintained to conform to the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed rescue boat in poor material condition. Rub rail on bow was peeling off pontoon, seat attachments were coming detached, vinyl on transom was not connected and would allow for water ingress, not suitable for crew.
74 SOLAS (2020) I/11a
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 27 March 2023
Resolved 28 March 2023
Resolution: RINA Class Surveyor issued a Condition of Class approving a temporary repair, with a permanent repair to be conducted by 30 APR 2023.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 March 2023
Resolved
07105 - Fire doors/openings in fire-resisting divisions
In order to contain a fire in the space of origin, the fire integrity of the divisions shall be maintained and openings and penetrations. PSCO observed 01 damaged A-0 self closing fire door (accommodation deck stairwell door) that would not prevent the passage of smoke or flame. Door latching system was completely missing, rendering door unable to remain shut to prevent the spreading of fire and smoke.
74 SOLAS (2014) II-2/9.1.3
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 27 March 2023
Resolved 27 March 2023
Resolution: Vessel crew installed new lock on A-0, self-closing fire door. Repair and gas-tight seal verified by RINA Class Surveyor and PSCO.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 27 March 2023
Resolved
11113 - Launching arrangements for rescue boats
The rescue boat embarkation and launching arrangements shall be such that the rescue boat can be boarded and launched in the shortest possible time. PSCO observed crew unable to lower rescue boat, due to lack of proper maintenance of falls. PSCO was informed that rescue boat and davit inspections are conducted every Saturday, last inspection was 25MAR23.
74 SOLAS (20) Ch III Reg 17.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 27 March 2023
Resolved 27 March 2023
Resolution: Crew conducted maintenance on falls. PSCO observed satisfactory lowering of rescue boat to embarkation level.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 March 2023
Resolved
11108 - Inflatable liferafts
Each liferaft shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the Code. PSCO observed that the 05 liferafts had non-SOLAS approved weak links attached. These non-SOLAS approved arrangements are unsuitable for launching requirements for the vessel's area of operation, thus compromising the safety of the crew in an emergency situation where they would need to abandon ship.
74 SOLAS (20) Ch III Reg 13.4.2
Condition: Invalid
Action required: 30 - Ship detained
Due 27 March 2023
Resolved 27 March 2023
Resolution: Crew installed Hammar H20 SOLAS type HRUs on 05 liferafts. RINA Class Surveyor and PSCO validated properly installation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 March 2023
Resolved
04103 - Emergency, lighting, batteries and switches
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Emergency lighting around the main superstructure and embarkation station areas were of a bayonet base type style light bulb with a 24volt/20-watt capacity. When illuminated, PSCO observed that the light bulbs did not put out adequate illumination to light pathway from main superstructure to embarkation/muster station in case of any emergency.
74 SOLAS (20) Ch III Reg 11.4
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 March 2023
Resolved 27 March 2023
Resolution: Crew produced documentation showing that installed lightbulbs were of the right size, voltage, and wattage considered adequate illumination for use by emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 March 2023
Resolved
07110 - Fire fighting equipment and appliances
Maintenance, testing, and inspections shall be carried out based on the guidance developed by the Organization. PSCO observed multiple portable fire-extinguishers, emergency escape breathing apparatuses, and fire-locker inspection tags that were not completed for the month of February 2023. Although, the monthly SMS check-sheet had been marked as completed.
74 SOLAS (2004) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2023
Resolved 28 March 2023
Resolution: RINA Class Surveyor conducted audit and monthly inspection of firefighting equipment with crew for the month of March 2023.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 March 2023
Resolved
03109 - Machinery space openings
Machinery space openings in position 1 or 2 shall be properly framed and efficiently enclosed by steel casings of ample strength. PSCO observed the watertight door leading into emergency generator space to be missing the lower left swivel guide for the no. 5 dog arm. The door was able to be closed and secured, but unable to complete a watertight seal due to the dog arm being able to lock in place.
ICLL (88) CH.2/17.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 March 2023
Resolved 27 March 2023
Resolution: Crew installed swivel guide and reattached dog arm to E-Gen WTD. Proper installation and operation of WTD verified by RINA Class Surveyor and PSCO.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 December 2022
Resolved
Each liferaft shall be stowed fully equipped as required by the code.....If a weak link is used in a float free arrangement it shall break under strain of 2.2 +- 0.4kN. All painter lines were found attached to the ship's structure with no weak ink as required by liferaft approval letter. 74SOLAS20 III/13.1.4 LSA IV 4.1.6.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2022
Resolution: Weak links installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 December 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship is fit to Proceed to sea. PSCOs noticed stream of water leading from stbd engine block and when notified C/E could not explain. Source of leak is unknown.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2023
Resolution: RINA Attended and cleared outstanding def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 December 2022
Resolved
Oil fuel lines shall be screened to avoid oil spray or leakage onto sources of ignition. EDG lines were not suitably screened.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 December 2022
Resolution: Shielidng was added
14 - Pollution Prevention › 148 - Ballast Water › Ballast water report
Issued 5 December 2022
Resolved
For any vessel that is equipped with ballast water tanks and bound for ports or places in the United States, ballast water report must be submitted no later than 6 hours after arrival at the port or place of destination, or prior to departure from that port or place of destination, whichever is earlier. Vessel did not submit a Ballast Water Management Report to the National Ballast Information Clearinghouse within the required time.
33 CFR 151.2060(b)(3)
Action required: 10 - Deficiency Rectified
Resolved 5 December 2022
Resolution: Vessel submitted Notice of Arrival.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 13 May 2020
Resolved
A lighting system shall provide illumination throughout those parts of the ship normally accessible and used by the crew.
Safety flood lights and poop deck lights have been found damaged.
74SOLAS(09) II-1/41.2.1
Action 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 13 May 2020
Resolution: Lights have been repaired.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Navigational stern light found inoperable.
74SOLAS(14) I/11(a)
Action Taken: 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 13 May 2020
Resolution: Stern Light repaired
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 May 2020
Resolved
Rescue boats shall have sufficient mobility and maneuverability. Rescue boat outboard engine inoperable.
74SOLAS(14) III/31.2 LSA 5.1.1.7
Action 17ac
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 13 May 2020
Resolved 13 May 2020
Resolution: Rescue boat engine is has been restored to full operation.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 13 May 2020
Resolved
Rescue boat embarkation and launching arrangements shall be such that the rescue boat can be boarded and launched in the shortest possible time. Rescue boat davit found sheered off, deeming it inoperable.
74SOLAS(14) III/17.1
Action 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2020
Resolved 14 May 2020
Resolution: Load tested. Provided tech and class report. See documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 13 May 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. 02 Liferafts missing.
74SOLAS(14) I/11(a)
Action 17 ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2020
Resolved 14 May 2020
Resolution: Replaced missing liferafts. Reported missing liferafts to Canadian and US Coast Guard. Provided Class report. See documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 May 2020
Resolved
Each survival craft shall be stowed in a state of continuous readiness. Liferaft cradle found damaged.
74SOLAS(14) III/13.3
Action 17 ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2020
Resolved 14 May 2020
Resolution: Repaired damaged cradles. Provided Class report. See documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 13 May 2020
Resolved
An embarkation ladder complying with the requirements of paragraph 6.1.6 of the Code shall be provided at each embarkation station. Embarkation ladder found missing from its embarkation station and damaged.
74SOLAS(14) III/11.7
Action 17 ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2020
Resolved 13 May 2020
Resolution: Embarkation ladder repaired and placed back in ready setting.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 13 May 2020
Resolved
The construction ad materials of all means of access and their attachment to the ship's structure shall be to the satisfaction of the Administration. Catwalk gratings found missing.
74SOLAS(09) II-I/3-6.2.3
Action 16ac
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 27 May 2020
Resolved 13 May 2020
Resolution: Catwalk gratings replaced and restored.