MAURY USCG vessel records
← All vessels

APACHE

Built
1977
Last inspected
4 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 4 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2003–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ8019
154942
Flag
UNITED STATES
Maury page id
psix-154942

Documentation record

Registered dimensions (L × B × D)57.6 ft × 22.0 ft × 8.4 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)57.6 ft × 22.0 ft × 8.4 ft
ITC tonnageNot recorded
BuilderHENRY & BROUSSARD BOAT BLDR · MORGAN CITY, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SITKA Freight Barge · MISLE 52017 · 1 July 2003 · activity 1834104MEAGAN ANN Towing Vessel · MISLE 137015 · 1 July 2003 · activity 1834104

Inspection history · 16

4 May 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8332063
9 April 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8071845
2 May 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7898454
3 May 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7668060
14 March 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7650794
11 July 2022 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7471351
3 February 2022 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7380557
11 October 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7367587
23 September 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6923296
11 July 2019 Initial Certification · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6679616
26 September 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6548936
20 December 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4215067
2 August 2011 Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4160831
15 December 2006 MTSA Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2841282
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963163
1 July 2003 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1834104

Deficiency record · 22

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 May 2026 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. MI observed active leaking of water from overhead piping, dripping directly onto the starboard generator and its alternator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2026
Resolution: MI inspected satisfactory repair of leaking water pipe (toilet supply line). No further leaks observed over starboard generator. Generator tested; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2026 Resolved
Each towing vessel must have hoses and nozzles in accordance with paragraphs (d) of this section; The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosionresistant material capable of providing a solid stream and a spray pattern. Upon testing, fire nozzle was able to function in a spray pattern only, but could not provide a solid stream of water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2026
Resolution: MI tested new fire hoze nozzle and witnessed straight stream and spray feature. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2025 Resolved
Electrical components that pose an electrical hazard must be in an enclosure. MI identified port and starboard engine room electric bilge pumps plugged in to outlets rather than hardwired in enclosure with over current protection. 46 CFR 143.400(g)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 24 April 2025
Resolution: Vsl provided picture proof of rectification.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2025 Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight. MI identified unfilled cable transit bulk head penetration between engine room and forepeak space. 46 CFR 143.400(h)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 24 April 2025
Resolution: Vsl provided picture proof of rectification.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2025 Resolved
Extension cords must not be used as a permanent connection to a source of electrical power. MI identified extension chord permanently installed from engine room through bulkhead into forepeak space. 46 CFR 143.575(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2025
Resolved 24 April 2025
Resolution: Vsl provided picture proof of rectification.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 February 2022 Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. Vessel did not have updated paper charts onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Up-to-date paper charts placed onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 February 2022 Resolved
The Rules concerning shapes shall be complied with by day. Power-driven vessels underway (Rule 23). Towing and pushing (Rule 24). Vessel operator did not have onboard the required day shapes for a power driven vessel and for towing and pushing arrangements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Required day shapes placed onboard the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2022 Resolved
Each towing vessel must carry at least one appropriately-sized life jacket. Each life jacket must be marked in block capital letters with the name of the vessel. Inspector identified that one of the required lifejackets was not labeled with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Life jacket has been labeled with the vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2022 Resolved
The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1350 pounds. Inspector identified two life rings with deteriorated (unserviceable) grab lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Grab lines on life rings replaced (new/in-kind).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 February 2022 Resolved
At least one lifebuoy must have a lifeline, secured around the body of the lifebuoy. If more than one lifebuoy is carried, at least one must not have a lifeline attached. All lifebuoys found on vessel during inspection have lifeline attached.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Lifeline removed from one life buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2022 Resolved
A towing vessel that is certified for rivers, lakes, bays, and sounds, less then 3 nautical miles from shore must be equipped with an approved B-V semi-portable fire-extinguishing system to protect the engine room. Vessel's semi-portable fire-extinguisher was not on vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Semi-portable (160B) fire extinguisher placed onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2022 Resolved
A remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. During operational test the fuel shutoff valve for the starboard main engine and starboard generator found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Repair completed of both fuel shut-off.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 3 February 2022 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. On vessels with more than one operating station, one of them must be outfitted with a fire detection control panel. Any other operating stations must be outfitted with a remote indicator panel. The secondary operating station did not have a fire detection panel installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Fire detection panel installed at secondary operating station.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 February 2022 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Discovered open ground upon testing electrical outlet on bridge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2022
Resolved 4 March 2022
Resolution: Open ground on electrical outlet corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 October 2021 Resolved
A towing vessel subject to Subchapter M, and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. The vessel has not completed the required second annual COI inspection. COI second annual COI inspection was due no later than October 11, 2021.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2023
Resolution: As part of admin review, MI determined this deficiency to no longer be applicable to the vessel. Vessel was taken out of service and has since been brought back into service on a new CIO. This deficiency was issued on the previous COI. No further action.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 September 2020 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists. The following alarms: high bilge level, must be visible and audible at each operating station. Vessel found to be missing both visual and audible alarms at the 'crows next' primary operating station. Provide required alarms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 10 November 2020
Resolution: Installed alarm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 September 2020 Resolved
Each cable and wire on a towing vessel must be installed to meet the following requirements: each cable and wire must be supported to avoid chafing and other damage. Found multiple wires, below crows nest operating station, to be hanging/entering through the front of open cover on junction/fuse box. Ensure proper installation and support of wires.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2020
Resolved 10 November 2020
Resolution: Installed correctly
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2019 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet in length must be fitted with a floating electric water lights. Vessel is missing one of the two required floating electric water lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2019
Resolved 31 July 2019
Resolution: Required number of floaating electric water lights placed onboard the vessel.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 11 July 2019 Resolved
Emergency duties and duty stations must be posted at operating stations and in a conspicuous area. Station Bill (4 persons) requires updating to reflect the duties of Master, Mate and 2 deckhands.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2019
Resolved 31 July 2019
Resolution: Station Bill updated to reflect duties of required personnel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2019 Resolved
Machinery must be maintained to provide for safe operation of the towing vessel. Excessive leaking around the shaft packing was found on both the port and starboard shafts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2019
Resolved 31 July 2019
Resolution: Shaft packing replaced in kind and operating satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2019 Resolved
Master must ensure all life saving equipment is properly maintained and ready for service. Storage location of PFD's must be labeled/marked to allow easy identification of stowage and quantity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2019
Resolved 31 July 2019
Resolution: Location of PFD's properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 26 September 2018 Resolved
Vsl is broadcasting: MMSI from expired FCC License and Call Sign from expired FCC License.
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 October 2018
Resolved 1 November 2018
Resolution: AIS discrepancy corrected, AIS broadcasting all pertinent information.

Ownership record