Records from 1992 to 2024. Most recent: inspection, 20 September 2024.
Documentation record
Registered dimensions (L × B × D)73.5 ft × 27.2 ft × 11.1 ft
Registered tonnagegross 148 / net 101
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE EQUIPMENT & POWER · SEATTLE, WA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEWARK, NJ
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it148 - Regulatory (Subpart C or D), Gross Ton
101 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 42
20 September 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8009259
21 May 2024
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7916275
12 January 2023
Initial Certification · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7616749
15 December 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609610
19 July 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7510944
29 April 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7440815
23 March 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7417435
21 March 2022
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7415623
22 July 2021
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7264677
2 June 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7220364
2 June 2021
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7234432
21 July 2020
COI Inspection · Administrative Inspection · Initial Certification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7012363
25 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548618
6 January 2014
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4778213
26 October 2012
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4473238
7 February 2012
Administration
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4240109
12 June 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4058910
13 April 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3986229
30 November 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3659112
14 April 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3452452
7 April 2009
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3451469
4 February 2008
MTSA Verification · Uninspected Other
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3141623
25 October 2006
MTSA Verification
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2808421
7 September 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2771856
1 July 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1834104
21 April 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1797044
20 July 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 765922
19 July 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 199751
24 May 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 144913
20 October 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 121803
23 June 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 155899
28 August 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 755953
27 August 1998
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 199645
15 October 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 199750
15 October 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 765744
6 May 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 125931
6 November 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 56764
12 March 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 10582
20 May 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 35849
1 May 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1168897
30 April 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 49750
5 December 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 12709
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 July 2022
Resolved
All owners and operators of an existing towing vessel must have on board a valid COI prior to the specified phase-in period. This vessel has not scheduled an inspection or obtained a valid COI. The vessel shall be made available for Coast Guard COI inspection immediately and the vessel may no longer be permitted to operate.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 January 2023
Resolution: issued vessel COI -- see activity 7616749
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 July 2021
Resolved
A fixed fire pump must be capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute (lpm) (80 gallons per minute (gpm). Fire pump psi does not produce the minimum of 50 psi. - 46 CFR 142.325(a)(1) -
Action required: 705 - Other - as specified
Resolved 5 August 2021
Resolution: ABS attended the vessel
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 July 2021
Resolved
Fuel shutoff requirements; The valve must be operable from a safe place outside the space where the valve is installed. Fuel shutoff reach rods are inoperable.
- 46 CFR 137.220(c) -
- 46 CFR 143.260(d) -
Action required: 705 - Other - as specified
Resolved 5 August 2021
Resolution: ABS Attended vessel
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 July 2021
Resolved
When conducting an examination of a towing vessel as required by this subpart, the surveyor must determine whether any defect, deterioration, damage, or modifications of the hull and related structure and components may adversely affect the vessel's seaworthiness or fitness or suitability for its route or service. Vessel's shaft packing glands are leaking at an excessive rate which is causing the automatic bilge pumps to pump oily water overboard and into navigable waterways.
- 46 CFR 137.325(a) -
Action required: 705 - Other - as specified
Resolved 5 August 2021
Resolution: ABS Attended the vessel
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
Vsl is broadcasting invalid IMO # and Vsl is broadcasting Draft > than Beam
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 March 2022