Records from 1991 to 2026. Most recent: inspection, 9 January 2026.
Documentation record
Registered dimensions (L × B × D)110.4 ft × 32.0 ft × 16.6 ft
Registered tonnagegross 242 / net 172
ITC dimensions (L × B × D)110.4 ft × 32.0 ft × 16.6 ft
ITC tonnagegross 407 / net 122
BuilderMODERN MARINE POWER INC · HOUMA, LA, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 10 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it407 - Convention (Subpart B), Gross Ton
242 - Regulatory (Subpart C or D), Gross Ton
122 - Convention (Subpart B), Net Ton
172 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 45
9 January 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8293713
23 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8013659
27 July 2023
Deficiency Check · COI Inspection · Initial Certification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7746736
15 June 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7478054
23 June 2020
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 6985105
6 June 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6711703
22 June 2018
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6456428
12 November 2016
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6065152
15 June 2015
MTSA Verification · Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5153888
17 January 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5064415
27 April 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4847612
3 July 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4641392
3 July 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4646925
31 October 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4475662
28 August 2012
Industry Initiated Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4426291
25 November 2010
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3898962
9 September 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3868929
23 April 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3723296
10 January 2010
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3667451
18 September 2009
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3628082
18 August 2009
MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3569389
7 June 2009
Annual Inspection · MTSA Verification · Hawser Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3569800
27 December 2008
Administration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3385341
16 December 2008
Administration
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3380845
15 February 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3148114
8 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2531012
3 November 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2530702
14 September 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2492052
11 August 2005
Uninspected Other · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2459638
27 April 2005
MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2343944
11 April 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2331008
16 March 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2025725
23 October 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1938175
22 July 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1855589
27 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 80812
20 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1480637
25 November 1997
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 777303
23 May 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 129715
10 December 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 63505
29 May 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079444
14 March 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 182616
28 February 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 139106
27 January 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 646822
25 January 1994
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 165634
13 November 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 646816
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 October 2024
Resolved
High bilge level alarms must be visible and audible at each operating station. The alarm located at the operating station may be a summary alarm; if the alarm at the operating station is a summary alarm, the specific alarm condition must be indicated at the machinery or bilge location. Vessel operating station did not have audible/visual high bilge level alarms. O/O to install to satisfaction of attending marine inspector.
46CFR143.230(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 6 November 2024
Resolution: O/O installed an audible and visual high bilge level alarm at the operating station and above the engine room entrance.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 October 2024
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Vessel's lazarette high bilge level alarm was inoperable. O/O to repair or replace to satisfaction of attending marine inspector.
46CFR143.230(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 6 November 2024
Resolution: O/O replaced the high bilge level alarm float switch sending unit in the lazarette.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2024
Resolved
Except as provided in paragraph (a)(8) of this section, each towing vessel must have a fire-detection system installed to detect engine room fires. Vessel's fire detection panel secondary source of power batteries were inoperable. O/O to repair or replace batteries to satisfaction of attending marine inspector.
46CFR142.330(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 6 November 2024
Resolution: O/O replaced the fire detection panel on bridge 12 volt secondary power supply batteries.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2024
Resolved
All portable fire extinguishers, semi-portable fire-extinguishing systems, fire-detection systems, and fixed fire-extinguishing systems, including ventilation, machinery shutdowns, and fixed fire-extinguishing system pressure-operated dampers on board the vessel, must be inspected or tested at least once every 12 months, as prescribed in paragraphs (a)(1) through (8) of this section, or more frequently if otherwise required by the TSMS applicable to the vessel. Vessel's hydraulic pin room fixed CO2 system and portable fire extinguishers were outside of required annual system testing and inspection requirements. O/O to have systems serviced in accordance with manufacturers instruction and applicable regulations.
46CFR142.240(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 22 November 2024
Resolution: O/O had fire extinguishers in hydraulic pin room serviced and tagged to satisfaction of attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 October 2024
Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces. This may be accomplished by an installed detection system, or by using individual battery-operated detectors meeting UL 217 (incorporated by reference, see § 136.112 of this subchapter). Detection systems or individual detectors must be kept operational at all times when the crew is onboard the towing vessel. Vessel's smoke detectors throughout vessel were inoperable. O/O to repair or replace to satisfaction of attending marine inspector.
46CFR142.330(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2024
Resolved 22 November 2024
Resolution: O/O replaced expired smoke detectors with new to satisfaction of attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2023
No resolution recorded
Seawater cooling systems must be provided with isolation devices and marked. Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve, located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The valve must be clearly marked by labeling or color coding that enables the crew to identify its function. Vessel couldn't identify if the vessel have integral or non-integral keel cooler installed. Must provide of an integral or install isolation valves by next drydock.
46 CFR 143.250(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 August 2026
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 27 July 2023
No resolution recorded
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. All wastage of metal on and round the forward "H" bit must be cropped and renewed at next drydock.
46 CFR 144.200(b)
Action required: 705 - Other - as specified
Due 31 August 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 July 2023
Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Emergency escape hatch on the boat deck needs to be re-labeled on the exterior side.
46 CFR 144.160(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 15 August 2023
Resolution: Operator labeled the upper end of the escape hatch with the appropriate verbiage.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 July 2023
Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. Emergency escape hatch on the boat deck needs new gasket installed.
46 CFR 144.320(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2023
Resolved 15 August 2023
Resolution: Operator replaced gasket in hatch, no longer leaking.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 27 July 2023
Resolved
The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey.
MI observed pinhole leak just aft of escape hatch from boat deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2023
Resolved 28 August 2023
Resolution: Plug welded.