VICTORY I

VICTORY I is a 2001 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 2016, most recently in July 2026, along with 53 deficiencies, 2 operational controls and 2 casualty investigations between 2001 and 2015.

Records from 2001 to 2026. Most recent: inspection, 2 July 2026.

Built
2001
Last inspected
2 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9213129
Flag
BAHAMAS, THE
Maury page id
psix-15528

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4954 - Convention (Subpart B), Gross Ton
1486 - Convention (Subpart B), Net Ton
695 - Dead Weight, Metric Ton
3372 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 46

2 July 2026 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8426061
29 May 2026 MARPOL Annex V Examination · Vessel Attendance
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8383403
3 April 2026 COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8341544
5 November 2025 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8265027
8 August 2025 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8205401
5 August 2025 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8202599
15 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8186780
25 June 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8167510
13 May 2025 PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 8133097
16 April 2025 COC-CVE Annual · PSC A
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8109390
1 July 2024 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7946629
1 April 2024 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7888030
17 November 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7832103
20 October 2023 PSC B · COC-CVE Quarterly
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7810083
17 May 2023 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7690749
22 March 2023 PSC A · COC-CVE Annual
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7654839
25 August 2022 Deficiency Check
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7543320
8 August 2022 COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7525257
13 May 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7449799
13 March 2022 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7410067
10 February 2022 COC-CVE Initial · PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7392112
27 December 2021 Administrative Inspection · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7372781
19 May 2021 Appeal
Administrative · Commandant (CG-CVC) · Activity 7205885
17 May 2021 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7199119
7 May 2021 Administrative Inspection · Appeal
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7191579
26 April 2021 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7185581
25 April 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7185478
1 April 2021 Ballast Water Examination · PSC A
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7166199
8 October 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7073308
2 October 2020 Bulk Liquid Transfer Monitor
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7070205
20 September 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6817212
15 May 2019 COC-CVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6672465
24 April 2019 Ballast Water Examination · NPV Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6668668
9 October 2018 COC-CVE Quarterly
Type not classified · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6558532
31 July 2018 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6505550
3 June 2018 Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6433752
30 May 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6429943
4 May 2018 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6406007
18 April 2018 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6393082
14 October 2017 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6288518
31 July 2017 Deficiency Check · COC-CVE Quarterly
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6223050
24 March 2017 ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6109042
12 October 2016 Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6020857
11 July 2016 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5937819
23 June 2016 Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5914393
22 January 2016 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5801860

Deficiency record · 53

04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 13 April 2026 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed a gap between the lifeboat and the embarkation deck. Embarkation ramp was not made available to crew. Cite: 74 SOLAS 24 III/19.2.1 Action: 10 ac
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 April 2026
Resolved 13 April 2026
Resolution: Crew was instructed on proper use of the safety embarkation ramp to bridge the gap between the lifeboat and embarkation deck.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 April 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Sprinkler pump found inoperable. PSCO could not test the automatic operation of sprinkler pump. 74 SOLAS 20 II-2/14.1.1 17 ac
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2025
Resolved 16 April 2025
Resolution: PSCO observed the sprinkler pump to be operational prior to departure from the vessel.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 April 2025 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed several fixed fire fighting nozzle covers throughout the vessel that had been painted over and could not prove proper function. 74 SOLAS 20 II-2/14.1.1 17 ac
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2025
Resolved 16 April 2025
Resolution: PSCO observed the fire fighting nozzle covers to be functional after the crew made repairs.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 April 2025 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed crewmembers unable to safely control the liferaft bowsing lines during their abandon ship drill. 74 SOLAS 20 III/19.2.1 16 ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 5 May 2025
Resolution: On 05MAY2025 VICTORY I provided via email evidence of crew training for life rafts 1-4 conducted on 01MAY2025, including crew screening of embarkation video and practical training of launching the life rafts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 April 2025 Resolved
The bulkhead deck or a deck above it shall be weather tight. All openings in the exposed weather deck shall have coamings of ample height and strength and shall be provided with efficient means for expeditiously closing them weather tight. PSCO observed (01) weather tight door on deck 04 starboard side and (01) weather tight door to cabin 217 on the port side not be weather tight. 74 SOLAS 04 II-1/20.2 16 ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2025
Resolved 16 April 2025
Resolution: PSCO observed the doors to operate as intended after crew members completed repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2025 Resolved
The construction of all doors and door frames in "A'' class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Such doors and door frames shall be constructed of steel or other equivalent material. PSCO oberved one side of fire door on deck 02 midship, FD's #323, 331, and main laundry not close. 74 SOLAS 01 II-2/30.2 10 c
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: PSCO observed the doors to operate as intended after crew members completed repairs.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 April 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. The uniform rate of closure for sliding fire doors shall be of no more than 0.2 m/s and no less than 0.1 m/s. PSCO observed fire doors 364,365 and 432, which closed too fast. In addition, 432 did not latch. 74 SOLAS 01 II-2/30.4.2 10 ac
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: PSCO observed the doors to operate as intended after crew members completed repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 April 2025 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within 2 min an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations and machinery spaces of category A. PSCO observed two heat detectors in the engine room that did not initiate a visual and audible alarm. 74 SOLAS 01 II-2/13.1.4 10 ac
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: PSCO observed the fire detectors to operate as intended.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 20 October 2023 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be of photoluminescent material or marked by lighting. PSCO observed low location fluorescent tape to not be at all points of the escape route. 74 SOLAS 01 II-2/28.1.5.10 Action Taken: 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2023
Resolved 17 November 2023
Resolution: Observed installation of LLL.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 October 2023 Resolved
Openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the division in which they are fitted. PSCO observed FSD 152 was buckled and not keeping the fire boundary. 74 SOLAS 01 II-2/30.1 Action taken: 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 October 2023
Resolved 20 October 2023
Resolution: Witnessed satisfactory close of doors after crew made adjustments.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 October 2023 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed numerous crew members unfamiliar with basic fire fighting procedures and emergency duties. 74 SOLAS 20 III/19.1 Action taken: 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 October 2023
Resolved 20 October 2023
Resolution: Ship conducted training before departure. See documentation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 March 2023 Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures shall satisfy the following requirements: The doors shall be self-closing and be capable of closing against an angle of inclination of up to 3.5 degrees opposing force. FSD 141 and 434 did not fully close upon remote and local testing.
Action required: 10 - Deficiency Rectified
Due 27 March 2023
Resolved 27 March 2023
Resolution: Deficiency rectified
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 August 2022 Resolved
Means of Escape- Escape from the engine room workshop is blocked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2022
Resolved 8 August 2022
Resolution: Escape route is clear, and the deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 8 August 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Self lowering cord for Life Boat #1 will not allow the boat to go all the way to the water.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2022
Resolved 8 August 2022
Resolution: The self-lowering cord was adjusted, allowing the boat to be lowered to the water. The deficiency was cleared.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 August 2022 Resolved
Means of escape. Missing exit signs missing in the gym, spa, and grill restaurant.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2022
Resolved 8 August 2022
Resolution: New signs were installed and function as designed. The deficiency is cleared.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 8 August 2022 Resolved
On-board training in the use of the ship's life-saving appliances, including survival craft equipment and in the use of the ship's fire-extinguishing appliances shall be given as soon as possible but not later than two weeks after a crew member joins the ship. Crew unfamiliar location of emergency tool kit on lifeboats, how to operate lifeboat emergency steering, who should start the lifeboat engines and overall crew responsibilities for launching life raft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2022
Resolved 25 August 2022
Resolution: Received Class report attesting to satisfactory performance of the crew. The deficiency is cleared.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 February 2022 Resolved
All opening shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. The following fire screen doors did not latch closed upon activation of closure mechanism: FD 48,63,365, main laundry room door, and ECR entry door. 74 SOLAS 01 II-2/30.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 February 2022
Resolution: Vessel rectified deficiency while team was onboard
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 February 2022 Resolved
All “A” class doors located in stairways, public spaces and main vertical zone bulkheads in escape routes shall be equipped with a self-closing hose port. PSCO observed hose ports which are not self-closing in the following: FSD 155, 364, 440. 74SOLAS 01 II-2/30.7
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 24 February 2022
Resolution: The hose ports on the self closing doors were serviced and now work properly. Witnessed by Class.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 February 2022 Resolved
The minimum for integrity of all bulkheads and decks shall be as prescribed in tables 26.1 and 26.2. PSCO observed penetration in bulkhead near FSD 365 next to main vertical zone, and penetration in laundry door. 74SOLAS 01 II-2/26.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 24 February 2022
Resolution: The penetrations were repaired with fire stop. Witnessed by Class.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 10 February 2022 Resolved
Where A class divisions are penetrated for the passage of electric cables, arrangements shall be made to ensure that the fire resistance is not impaired. Electrical penetration in aft fire boundary of the navigation bridge, over exit door, found not intact as designed. 74 SOLAS 01 II-2/18.1.1
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2022
Resolved 24 February 2022
Resolution: Electrical cable penetration was properly repaired. Witnessed by Class.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to seas without danger to the ship or persons on board. PSCO observed a fault alarm on the transitional power unit and the ship’s crew was unable to clear the fault. 74 SOLAS 20 I/11(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2022
Resolved 11 March 2022
Resolution: Received documentation attesting that fault has been rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 February 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed dead-end wires in overhead of the EDG space. 74 SOLAS 04 II-1/45
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 10 February 2022
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 10 February 2022 Resolved
A public address system or other effective means of communication shall be available throughout the accommodation and service spaces and control stations and open decks. PSCO did not hear PA announcements in muster station A (Compass Lounge). 74 SOLAS 01 II-2/40.5
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 February 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 April 2021 Resolved
Where ventilation systems penetrate decks, precautions shall be taken, in addition to those relating to the fire integrity of the deck required by regulations II-2/18.1.1 and 30.5. Ventilation dampers throughout the vessel fail to close and are unavailable in the event of emergency.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Atteneded vessel and witnessed proper operation of dampers.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 1 April 2021 Resolved
Passenger ships of 500 gross tonnage and over shall carry at least one rescue boat complying with the requirements of section 5.1 of the LSA Code on each side of the ship. Vessel is currently outfitted with two lifeboats. Second lifeboat does not conform to LSA Code 5.1 requirements for a rescue boat and is only certificated as a lifeboat under 4.4, 4.5.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Life boat replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 April 2021 Resolved
Every inflatable life raft shall be serviced at intervals not exceeding 12 months. No available records of onboard inspection having been carried out by certified inspection personnel in the last 12 months. [IAW with MSC.1/CIRC.1328]
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Documentation presented attests to current inspection of inflateable liferafts.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 April 2021 Resolved
Rescue boats shall be capable of carrying at least five seated persons and a person on a stretcher. Rescue boat was modified from its type approval, preventing access of a stretcher in the event of an emergency.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Replaced rescue boat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 April 2021 Resolved
Where risk from overspeeding machinery exists, means shall be provided to ensure that the safe speed is not exceeded. #1 Main propulsion engine did not shutdown at over speed condition.
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Engine overspeed trip tested and found satisfactory. Condition of Class issued unitl 30April21. Alram not indicationg overspeed trip.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Multiple power strip installations in server room and exposed wires above emergency generator fuel tank found presenting inherent risk to shipboard personnel.
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Powerstrips and exposed wires removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chaffing or other damage. The wiring beneath the bridge console contained several extension cords and power strips. Additionally, the wires were not supported and bundled on the deck causing a fire hazard.
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Powerstrips and extension cordsv removed. Wires found properly supported and secured.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 April 2021 Resolved
Nautical charts and nautical publications, such as sailing directions, lists of lights, notices to mariners, tide tables and all other nautical publications necessary for the intended voyage, shall be adequate and up to date. Vessel’s charts on ECDIS, nautical publications, light lists, and notice to mariners not updated since 2015.
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: Charts, nautical publications, light lists, and notice to mariners updated as of 01 April 2021.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Switchboards in engine control room and emergency generator have missing fault lights, power lights, and running lights presenting inherent hazard to shipboard personnel.
Action required: 30 - Ship detained
Resolved 3 April 2021
Resolution: lamps replaced. observed proper operation of lamp test.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 1 April 2021 Resolved
Masters, officers, ratings qualified in accordance with Chapters I, II, III and VII and other personnel designated on the muster list to assist passengers in emergency situations on board passenger ships, shall complete passenger ship crowd management training as specified in section A-V/2 paragraph 3 of the STCW code. Third mate as required by safe manning document and with associated shipboard duties is missing crowd management cert. STCW I/4 and SOLAS 5.14
Action required: 30 - Ship detained
Resolved 4 April 2021
Resolution: Certificate issued.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2021 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. The following electrical panels were missing circuit breakers and did not contain spacers: HVAC Room 3, HVAC Power Panel P209, Power Panel P418, IT Office Power Panel, and Power Panel P208.
Action required: 30 - Ship detained
Resolved 4 April 2021
Resolution: Observed correction of electrical panels. Missing circuit breakers and spacers replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 1 April 2021 Resolved
All lifeboats except free-fall lifeboats shall be provided with at least one drain valve fitted near the lowest point in the hull which shall automatically open to drain water from the hull when the lifeboat is not waterborne and shall automatically close to prevent entry of water when the lifeboat is waterborne. The cork plug was found cracked, no longer in good and serviceable condition, and does not properly prevent entry of water when lifeboat is waterborne
Action required: 30 - Ship detained
Resolved 4 April 2021
Resolution: Observed new automatic drain plugs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 April 2021 Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency for a period of 36h. Emergency lighting (22) failed through multiple areas of deck, embarkation areas and accommodation alleyways, and would not be available in the event of an emergency.
Action required: 30 - Ship detained
Resolved 4 April 2021
Resolution: Vessel switched to emergency power. Witnessed proper operation of emergency lighting.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 1 April 2021 Resolved
At least 3 two-way VHF radiotelephone apparatus shall be provided on every passenger ship. Such apparatus shall conform to performance standards not inferior to those adopted by the Organization. If a fixed two-way VHF radiotelephone apparatus is fitted in a survival craft it shall conform to performance standards not inferior to those adopted by the Organization. Vessel’s two way radios did not conform to the power requirements of IMO A .809(19). The three spare batteries were expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2021
Resolution: Master of vessel produced 3 new batteries.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 April 2021 Resolved
Each power-operated sliding watertight door shall be provided with an audible alarm which shall sound for at least 5s but not more than 10s before the door begins to move. Sliding water tight door #55 did not alarm prior to moving.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2021
Resolution: Witnessed proper operation of alarm for power-operated sliding water tight door.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 April 2021 Resolved
In addition to complying with the specific provisions for fire integrity of bulkheads and decks mentioned elsewhere in this part, the minimum fire integrity of all bulkheads and decks shall be as prescribed in Tables 26.1 and 26.2. The wire penetrations located in HVAC Room 3 are not properly installed per manufacturers instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2021
Resolution: Witnessed relocation of cables to seperate blocks.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 1 April 2021 Resolved
Machinery spaces of category A shall be adequately ventilated so as to ensure that when machinery therein are operating at full power in all weather conditions, an adequate supply of air is maintained. Vessel has redirected supply air for the e-gen space to cool the power transformers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2021
Resolution: Crew removed alteration of vent pipe.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 April 2021 Resolved
In addition to complying with the specific provisions for fire integrity of bulkhead and decks mentioned elsewhere in this part, the minimum fire integrity of all bulkheads and decks shall be as prescribed in tables 26.1. Missing A-60 insulation in the overhead of the emergency engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2021
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 April 2021 Resolved
Each completed operation shall be signed by the officer or officers in charge of the operations concerned and completed pages shall be signed bythe master of the vessel. Master did not sign oil record book on three pages in AUG 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2021
Resolution: Master signed pages.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 1 April 2021 Resolved
Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all time. Multiple items per the fire control plan were missing such as spanner wrenches in hose station C1 and C5 and mist nozzles in the emergency generator space.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2021
Resolution: Observed new spanner wrenches in hose stations and mist nozzle in emergency generator space.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 1 April 2021 Resolved
Passenger Ship Safety Certificate shall be issued after an initial or renewal survey to a passenger ship which complies with the relevant requirements of Chapter II-I, II-2, III, IV, and V and any other relevant requirements of the present regulation. Passenger Ship Safety Certificate does not reflect any exemptions. Onboard documentation indicates that a flag state exemption was issued for II-2/28.1.5.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2021
Resolution: Certificate corrected.
01 - Certificates & Documentation › 013 - Documents › Ship Energy Efficiency Management plan
Issued 1 April 2021 Resolved
An International Energy Efficiency Certificate for the ship shall be issued after a survey in accordance with the provisions of regulation 5.4 of this Annex to any ship 400 gross tonnage and above before that ship may engage in voyages to ports or offshore terminals under the jurisdictions of other parties. The certificate has the vessel propulsion plant listed as diesel electric which does not accurately represent the operation status of the propulsion plant the vessel is fitted with.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 April 2021
Resolution: Certificate corrected.
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 1 April 2021 Resolved
The company should establish procedures to ensure the ship is maintained in the conformity with the provisions of the relevant rules and regulations. Based on the overall materiel condition of the vessel as substantiated by the objective evidence cited above, an additional external verification is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2021
Resolved 20 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 October 2020 Resolved
All of vessel's statutory documentation is expired due to layup and under survey status per Bureau Veritas. This conflicts with Bahamas lay up status approval and CVC work instruction -018(1) Site: Resolution A.1052(27)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2019 Resolved
Every shaft used for transmission of power to machinery essential for the propulsion shall be so designed and constructed to withstand the max working stresses which they may be subjected in all service conditions. The starboard main engine shaft bearing failed resulting in the inability to use the starboard main engine. 74 SOLAS (2009) II-1/27.3
Action required: 17 - Rectify deficiencies prior to departure
Due 20 September 2019
Resolved 23 September 2019
Resolution: Recieved Class Report
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2019 Resolved
Fire Doors in main vertical zone bulkheads, gallery boundaries and stairway enclosures shll be self-closing. Fire doors 137, 151, 152, 247 and the deck 2 starboard mooring station door did not latch when self-closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 16 May 2019
Resolution: Vessel adjusted the fire doors and now work properly when self-closing.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 18 April 2018 Resolved
1581 - Rudder angle indicator - The angular position of the rudder shall be indicated on the navigation bridge and be recognizable in the steering gear compartment. Rudder angle indicator on bridge and steering gear do not indicate the angle of the rudder. - 74SOLAS(2004 cons)II-1/29.11
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 4 May 2018
Resolution: Class submitted a report attesting that this does not apply to the vessels arrangements. See attached report.
Lifesaving › Lifeboat Equipment › Oar
Issued 18 April 2018 Resolved
0611 - lifeboat inventory - The normal equipment of every lifeboat shall consist of sufficient bouyant oars. Lifeboat number 1 has only one oar. - 74SOLAS(2014 cons)III/34 LSA Code 4.4.8.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 4 May 2018
Resolution: Class sent report (attached) say the lifeboats only need one oar and one crutch.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2018 Resolved
0925 - Musters and drills - Crew members with enclosed space entry or rescue responsibilities shall participate in an enclosed space entry and rescue drill to be held on board the ship at least once every two months. Vessel has not conducted enclosed space entry and rescue drill. - 74SOLAS(2014 cons)III/19.3.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2018
Resolved 4 May 2018
Resolution: class submitted a report attesting that an enclosed space entry drill was carried out on 19APR2018. See attached report
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 July 2017 Resolved
Maintain on the vessel adequate in-date supplies of anti-viral medications and other medications to prevent sexually transmitted diseases after a sexual assault. No anti-retroviral medications on board vessel. - CVSSA 2010 3507/D1
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 23 August 2017
Resolution: Received proof of delivery to vsl.

Casualty record · 2

27 October 2001Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1738999
19 June 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 29 injured · activity 5158173
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

CAPE MAY LIGHT (2001), SAINT LAURENT (2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.