Inspection history · 29
30 September 2015
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5732733
8 September 2011
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4139015
26 December 2006
Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2846486
13 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2624161
15 June 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2391463
31 May 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2373999
26 May 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2373848
28 March 2005
Damage Survey · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2321642
25 March 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2322115
13 January 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2274898
4 September 2004
Uninspected Other · Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2190113
3 September 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2188946
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999677
9 October 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1937545
23 February 2000
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 212110
12 August 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 795645
2 May 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 95859
1 May 1998
Uninspected Towing Vessel
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1460187
22 January 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 769080
18 January 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 198798
17 December 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 398802
22 November 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 661594
20 November 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 76811
16 November 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 44740
16 November 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 661595
6 April 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 661596
15 March 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 108705
4 March 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 307685
28 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1289928
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 28 March 2005
Resolved
03 lifejackets must be replaced due to wearing.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2005
Resolved 11 April 2005
Navigation › Piloting/Steering › Magnetic Compass
Issued 28 March 2005
Resolved
Required light in compass not in service.
Action required: 705 - Other - as specified
Due 28 April 2005
Resolved 11 April 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 March 2005
Resolved
Shaft packing missing.
Action required: 705 - Other - as specified
Due 28 April 2005
Resolved 11 April 2005
Stability › Watertight Integrity › General
Issued 28 March 2005
Resolved
Man hole covers need to be watertight.
Action required: 705 - Other - as specified
Due 28 April 2005
Resolved 11 April 2005
Stability › Watertight Integrity › General
Issued 28 March 2005
Resolved
Man hole covers need to be watertight.
Action required: 705 - Other - as specified
Due 28 April 2005
Resolved 11 April 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 September 2004
Resolved
Water flowing in through shaft packing on port and starboard propeller shafts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 4 September 2004
Resolution: Tighten shaft packing
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 4 September 2004
Resolved
Out of date charts with no chart corrections, no CG light list, no updated CG Notice to Mariners, 1997 edition of US Coast Pilot, no tide tables.
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: All pubs and charts updated
Navigation › Piloting/Steering › Magnetic Compass
Issued 4 September 2004
Resolved
Magnetic compass not illuminated, no deviation card
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Compass swung, new deviation card provided, new light installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 September 2004
Resolved
Mast towing lights not operable
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: New lights installed and tested
Stability › Unintentional Flooding › General
Issued 4 September 2004
Resolved
Excessive amount of oily water in engineroom bilges
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 8 September 2004
Resolution: Bilges pumped out (800 gal), source of flooding (shaft packing) fixed
Stability › Water on Deck › General
Issued 4 September 2004
Resolved
Apprx. 1ft of aft deck underwater due to excessive water in engineroom bilges
Action required: 705 - Other - as specified
Due 4 September 2004
Resolved 4 September 2004
Resolution: Counter ballast using clean water into bow ballast compartments.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 4 September 2004
Resolved
Radar endorsement expired, no TOAR endorsement.
Action required: 705 - Other - as specified
Due 4 October 2004
Resolved 30 September 2015
Engineering › Steering Gear System › Hydraulic Hose
Issued 4 September 2004
Resolved
Hydraulic hose on steering gear pump worn through to inner liner.
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Hose replaced
Engineering › Fuel Oil Service System › Hose
Issued 4 September 2004
Resolved
Fuel line hose of fuel transfer pump cracked and leaking
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Hose replaced
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 4 September 2004
Resolved
Hydraulic hose to clutch worn through to inner liner
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Hose replaced
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 September 2004
Resolved
Exhaust lagging and shielding unwrapped, hanging, or missing from all engineroom exhaust piping
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Exhaust problems repaired
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 September 2004
Resolved
port MDE exhaust pipe leaking exhaust fumes into engineroom
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Exhaust problem repaired
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 4 September 2004
Resolved
Speed control governor not operating correctly, possible run away condition when not underload
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: New governor installed and tested under load
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 September 2004
Resolved
Exhaust flex coupling wire mesh broken through.
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Exhaust problem repaired
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 September 2004
Resolved
V-belt guard, port diesel generator not covering turning belts or pulleys.
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Guard installed properly
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 September 2004
Resolved
Exposed openings in engineroom and pilot house circuit breaker panels
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Problem repaired
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 4 September 2004
Resolved
No face plate on receptacle outlet located on starboard side of wheelhouse
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Problem repaired
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 4 September 2004
Resolved
Circuit breaker labels rubbed off on engineroom circuit breaker panel
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Circuit breakers labled
Electrical › Electrical Distribution System (service) › Switchboard
Issued 4 September 2004
Resolved
No electrical protective matting in front of switchboard
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Electrical matting installed
Electrical › Lighting (service) › Lighting Fixture
Issued 4 September 2004
Resolved
No protective globe for light on aft deck or spotlight aft of wheelhouse.
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Lighting globe installed
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 September 2004
Resolved
Several deck rails & stancions around pilot house and accomodation area badly rusted and no longer attached to deck
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Deck rail, stantion, ladder rail repaired
Construction/Loadline › Structures › Door
Issued 4 September 2004
Resolved
FWD and AFT access doors to engineroom rusted though at bottom of door, gasket no longer servicable.
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: FWD & AFT doors repaired, new gasket installed
Deck/Cargo › Towing › Chocks
Issued 4 September 2004
Resolved
Tow / mooring bit on starboard side torn off deck, second upright of bit cracked along bottom weld
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Tow/Mooring bit replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 September 2004
Resolved
Wiring to AC unit on aft deck of pilot house exposed, thermostate wiring bare ended and laying on deck
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: New conduit and weather proof box installed
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 4 September 2004
Resolved
Excessive amounts of waste materials, debris, and rubbish throughout vessel
Action required: 705 - Other - as specified
Due 9 September 2004
Resolved 10 September 2004
Resolution: Problem resolved
Navigation
Issued 1 May 1998
Resolved
UPDATE CHARTS WITH BROADCAST NOTICE TO MARINERS.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Lifesaving
Issued 1 May 1998
Resolved
VESSEL MUST REPAIR AND REPLACE DAMAGED AREAS OF ENGINE ROOM CAUSED BY FIRE.
Condition: Unknown
Due 1 June 1998
Resolved 27 May 1998
Lifesaving
Issued 1 May 1998
Resolved
VESSEL TO BE RE-INSPECTED BEFORE GETTING UNDERWAY ON ITS OWN POWER.
Condition: Unknown
Due 1 June 1998
Resolved 27 May 1998
Documentation
Issued 17 December 1996
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION. (MISSING)
Condition: Unknown
Due 24 December 1996
Resolved 24 December 1996
Navigation
Issued 17 December 1996
Resolved
PROVIDE A BELL. (MISSING)
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Lifesaving
Issued 17 December 1996
Resolved
REPLACE RING BUOYS. (DRY ROTTED)
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 17 December 1996
Resolved
PROVIDE INLAND NAVIGATION RULES. (MISSING).
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 17 December 1996
Resolved
PROVIDE A FCC LICENSE. (MISSING)
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Documentation
Issued 17 December 1996
Resolved
PROVIDE AN OIL POLLUTION PLACARD. (MISSING)
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Fire Fighting
Issued 17 December 1996
Resolved
SERVICE FIRE EXTINGUISHERS. (NUMEROUS OUT OF SERVICE)
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Construction/Loadline
Issued 17 December 1996
Resolved
RENEW WASTED STARBOARD SIDE BULKHEAD IN ENGINE ROOM.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Electrical
Issued 17 December 1996
Resolved
REPAIR OR REPLACE EXPOSED ELECTRICAL WIRES THROUGHOUT VESSEL.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 4 March 1986
Resolved
VESSEL HAD ENGINE OIL DRAINED DIRECTLY INTO ENGINEROOM BILGE BY A MEMBER OFTHE VESSEL'S CREW, IN VIOLATION OF 33CFR155.770.
Condition: Unknown
Due 24 December 1996
Resolved 24 December 1996
Accommodation/Occupational Safety
Issued 4 March 1986
Resolved
VESSEL WAS EQUIPPED WITH INSTALLED TOILETS AND DID NOT HAVE ON BOARD A MARINE SANITATION DEVICE AS REQUIRED BY 33CFR159.7(C). RAW SEWAGE WAS DISCHARGED DIRECTLY OVERBOARD.
Condition: Unknown
Due 24 December 1996
Resolved 24 December 1996
Engineering
Issued 4 March 1986
Resolved
VESSELS FIXED FUEL OIL CONTAINMENT WAS FULL OF FUEL TO A POINT SO AS TO RENDER THE FUEL OIL VENTING SYSTEM TO BE INEFFECTIVE.
Condition: Unknown
Due 24 December 1996
Resolved 24 December 1996