MAURY USCG vessel records
← All vessels

A N TILLETT

Built
1978
Last inspected
27 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 27 February 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 23 calendar years (1991–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7829364
WDG7941
157441
Flag
UNITED STATES
Maury page id
psix-157441

Documentation record

Registered dimensions (L × B × D)69.2 ft × 24.1 ft × 12.0 ft
Registered tonnagegross 97 / net 65
ITC dimensions (L × B × D)69.2 ft × 24.1 ft × 12.0 ft
ITC tonnageNot recorded
BuilderMARINE POWER & EQUIPMENT · SEATTLE, WA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 30 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it65 - Regulatory (Subpart C or D), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 40 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 4 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MICHAEL C Towing Vessel · MISLE 90654 · 28 October 2012 · activity 4503574MARILYN MONROE Freight Barge · MISLE 48291 · 22 July 1994 · activity 1819180-2 Freight Barge · MISLE 49688 · 22 July 1994 · activity 1819WENDY O Towing Vessel · MISLE 147288 · 22 July 1994 · activity 1819

Inspection history · 40

27 February 2026 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8318661
14 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111720
5 February 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8074827
5 February 2024 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7861016
6 March 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646451
4 August 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7524687
8 April 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7427416
9 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7393685
29 July 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7272067
29 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7185920
1 September 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7047462
20 March 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6932499
1 August 2019 In-Service Inspection · Administrative Inspection · Construction Oversight · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6769404
14 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6540574
31 August 2018 DAPI Audit · Initial Certification · Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6527617
30 March 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5096102
4 October 2013 DAPI Audit · MTSA Verification · Industry Initiated Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4728710
28 October 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4503574
12 April 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4285641
29 April 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4004362
6 May 2010 Industry Initiated Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3735870
2 April 2010 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3716002
12 June 2008 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3320950
1 May 2008 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3196776
23 March 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2895386
12 March 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2886688
25 January 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2861832
4 December 2006 Uninspected Other · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2833993
16 May 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2650723
21 September 2005 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2498175
7 August 1999 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 106706
19 January 1999 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 674519
1 January 1999 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 176050
30 December 1998 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 26751
25 October 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 198947
25 October 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 764055
30 January 1998 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 9725
28 September 1997 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 131294
22 July 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1819
15 August 1991 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 674512

Deficiency record · 35

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 February 2024 Resolved
Vessel fixed CO2 system failed to shut down main engines and generator. Operate system as semi portable until repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 19 February 2024
Resolution: Provided means for fixed fire to shut down engines.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 February 2024 Resolved
FCC Safety certificate found to be expired. Provide CG with valid certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 6 February 2024
Resolution: Provided certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 February 2024 Resolved
FCC Bridge to Bridge certificate found to be expired. Provide CG with valid certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 6 February 2024
Resolution: Provided certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2023 Resolved
STBD steering limit switch not secured to bracket; hanging by its electrical cable. Remount.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2023
Resolution: Received picture of corrected item.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2023 Resolved
Diesel fuel tank level indicator sight glass missing protective guard to prevent fuel leak. Install approved protective guards around sight glass indicators.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 April 2023
Resolution: Recieved picture of corrected item.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2023 Resolved
Unapproved waste receptacle found in Engine room; remove and replace with approved receptacle.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 April 2023
Resolution: Recieved pictures of corrected item.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2021 Resolved
Required vessel security drills were not completed as of 31MAR2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2021
Resolved 7 May 2021
Resolution: Received security drill training documentation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 March 2020 Resolved
Make AIS operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: Found operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2020 Resolved
Complete inspection/record of towing gear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: Record of towing gear inspection provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2020 Resolved
Provide 02 additional lifejackets/immersion suits at main operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2020
Resolution: Picture of equipment on bridge provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2020 Resolved
Complete required tests/inspections and log in towing vessel record or official logbook. (MDEs & Gens Low lube oil press/high jacket water temp, pre-departure navigational assessment, etc.)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 26 May 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 March 2020 Resolved
Make bulkhead penetrations watertight at E/R door and main deck aft watertight door to galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 23 March 2020
Resolution: Photos of newly packed penetrations received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2020 Resolved
Mark stowage of lifejackets/immersion suits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 23 March 2020
Resolution: Picture received.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 20 March 2020 Resolved
Complete hydrostatic testing of portable oil service hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 26 May 2020
Resolution: Received receipt of testing.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #, MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: No longer in VIVS
Documentation › Logs/Records › Drug Test Records
Issued 2 April 2010 Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 30 April 2010
Resolved 4 June 2010
Documentation › Logs/Records › Logbook (official)
Issued 4 December 2006 Resolved
log tests underway and handover to prove tests completed
Action required: 705 - Other - as specified
Resolved 12 June 2008
Resolution: verified logs, discusssed proper entries
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 December 2006 Resolved
Provide original COD
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2007
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 4 December 2006 Resolved
Repair port searchlight. Prior to conducting cargo operations at night
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: test SAT
Navigation › Piloting/Steering › Marine Charts
Issued 4 December 2006 Resolved
Provide updated charts and publications prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 December 2006 Resolved
Repair navigation light wiring prior to night operations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: wiring repaired/resealed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 December 2006 Resolved
Remove household bulbs from navigation lights prior to night operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: removed
Communications › Radio Communications › EPIRB
Issued 4 December 2006 Resolved
renew EPIRB registration prior to operating more than 3nm from shore
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: renewed
Documentation › Markings/Placards › Vessel Number (state)
Issued 4 December 2006 Resolved
Provide correct name and hailing port on bow and stern prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: corrected
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 December 2006 Resolved
Provide engine room vent closures prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: installed
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 4 December 2006 Resolved
Remove oil slop from bilges prior to operating
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: removed slops
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 December 2006 Resolved
Provide remote means to close fuel oil supply valves prior to operating.
Action required: 705 - Other - as specified
Resolved 12 June 2008
Resolution: verified/tested FO remote closures
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 December 2006 Resolved
Provide PML for PFDs prior to a voyage outside the boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: provided
Documentation › Logs/Records › Garbage Recordkeeping
Issued 4 December 2006 Resolved
Provide and post garbage plan prior to voyage beyond boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2007
Documentation › Logs/Records › Garbage Recordkeeping
Issued 4 December 2006 Resolved
Provide garbage log prior to voyage beyond boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: New log book o/b
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 4 December 2006 Resolved
Provide oil transfer procedures prior to transfer or bunkering
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: OTP o/b
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 4 December 2006 Resolved
Provide fuel oil containment prior to operating.
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: new install
Documentation › Markings/Placards › Official Number (US)
Issued 4 December 2006 Resolved
Provide official number permanent on vessel frame
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: Pin punch on port ER fwd blkhd
Communications › Audible Communications › Bell
Issued 4 December 2006 Resolved
Provide bell of proper size prior to operating.
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: 8 inch bell aft deck
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 4 December 2006 Resolved
Prove operation of galley fire detection
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: replaced galley detector-test SAT

Ownership record