Inspection history · 40
27 February 2026
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8318661
14 April 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8111720
5 February 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8074827
5 February 2024
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7861016
6 March 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646451
4 August 2022
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7524687
8 April 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7427416
9 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7393685
29 July 2021
Bulk Liquid Transfer Monitor
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7272067
29 April 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7185920
1 September 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7047462
20 March 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6932499
1 August 2019
In-Service Inspection · Administrative Inspection · Construction Oversight · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6769404
14 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6540574
31 August 2018
DAPI Audit · Initial Certification · Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6527617
30 March 2015
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5096102
4 October 2013
DAPI Audit · MTSA Verification · Industry Initiated Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4728710
28 October 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4503574
12 April 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4285641
29 April 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4004362
6 May 2010
Industry Initiated Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3735870
2 April 2010
Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3716002
12 June 2008
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3320950
1 May 2008
DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3196776
23 March 2007
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2895386
12 March 2007
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2886688
25 January 2007
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2861832
4 December 2006
Uninspected Other · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2833993
16 May 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2650723
21 September 2005
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2498175
7 August 1999
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 106706
19 January 1999
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 674519
1 January 1999
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 176050
30 December 1998
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 26751
25 October 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 198947
25 October 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 764055
30 January 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 9725
28 September 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 131294
22 July 1994
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1819
15 August 1991
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 674512
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 February 2024
Resolved
Vessel fixed CO2 system failed to shut down main engines and generator. Operate system as semi portable until repaired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 19 February 2024
Resolution: Provided means for fixed fire to shut down engines.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 February 2024
Resolved
FCC Safety certificate found to be expired. Provide CG with valid certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 6 February 2024
Resolution: Provided certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 February 2024
Resolved
FCC Bridge to Bridge certificate found to be expired. Provide CG with valid certificate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 6 February 2024
Resolution: Provided certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 March 2023
Resolved
STBD steering limit switch not secured to bracket; hanging by its electrical cable. Remount.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 April 2023
Resolution: Received picture of corrected item.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2023
Resolved
Diesel fuel tank level indicator sight glass missing protective guard to prevent fuel leak. Install approved protective guards around sight glass indicators.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 April 2023
Resolution: Recieved picture of corrected item.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2023
Resolved
Unapproved waste receptacle found in Engine room; remove and replace with approved receptacle.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 April 2023
Resolution: Recieved pictures of corrected item.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2021
Resolved
Required vessel security drills were not completed as of 31MAR2021.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2021
Resolved 7 May 2021
Resolution: Received security drill training documentation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 March 2020
Resolved
Make AIS operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: Found operational.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2020
Resolved
Complete inspection/record of towing gear.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2020
Resolution: Record of towing gear inspection provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2020
Resolved
Provide 02 additional lifejackets/immersion suits at main operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2020
Resolution: Picture of equipment on bridge provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2020
Resolved
Complete required tests/inspections and log in towing vessel record or official logbook. (MDEs & Gens Low lube oil press/high jacket water temp, pre-departure navigational assessment, etc.)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 26 May 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 20 March 2020
Resolved
Make bulkhead penetrations watertight at E/R door and main deck aft watertight door to galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 23 March 2020
Resolution: Photos of newly packed penetrations received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 March 2020
Resolved
Mark stowage of lifejackets/immersion suits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 23 March 2020
Resolution: Picture received.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 20 March 2020
Resolved
Complete hydrostatic testing of portable oil service hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2020
Resolved 26 May 2020
Resolution: Received receipt of testing.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #, MMSI: Vsl is broadcasting MMSI from expired FCC License, CLSN: Vsl is broadcasting Call Sign from expired FCC License
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: No longer in VIVS
Documentation › Logs/Records › Drug Test Records
Issued 2 April 2010
Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 30 April 2010
Resolved 4 June 2010
Documentation › Logs/Records › Logbook (official)
Issued 4 December 2006
Resolved
log tests underway and handover to prove tests completed
Action required: 705 - Other - as specified
Resolved 12 June 2008
Resolution: verified logs, discusssed proper entries
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 December 2006
Resolved
Provide original COD
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2007
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 4 December 2006
Resolved
Repair port searchlight. Prior to conducting cargo operations at night
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: test SAT
Navigation › Piloting/Steering › Marine Charts
Issued 4 December 2006
Resolved
Provide updated charts and publications prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 December 2006
Resolved
Repair navigation light wiring prior to night operations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: wiring repaired/resealed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 December 2006
Resolved
Remove household bulbs from navigation lights prior to night operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: removed
Communications › Radio Communications › EPIRB
Issued 4 December 2006
Resolved
renew EPIRB registration prior to operating more than 3nm from shore
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: renewed
Documentation › Markings/Placards › Vessel Number (state)
Issued 4 December 2006
Resolved
Provide correct name and hailing port on bow and stern prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: corrected
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 December 2006
Resolved
Provide engine room vent closures prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: installed
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 4 December 2006
Resolved
Remove oil slop from bilges prior to operating
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 January 2007
Resolution: removed slops
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 December 2006
Resolved
Provide remote means to close fuel oil supply valves prior to operating.
Action required: 705 - Other - as specified
Resolved 12 June 2008
Resolution: verified/tested FO remote closures
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 December 2006
Resolved
Provide PML for PFDs prior to a voyage outside the boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: provided
Documentation › Logs/Records › Garbage Recordkeeping
Issued 4 December 2006
Resolved
Provide and post garbage plan prior to voyage beyond boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2007
Documentation › Logs/Records › Garbage Recordkeeping
Issued 4 December 2006
Resolved
Provide garbage log prior to voyage beyond boundary line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: New log book o/b
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 4 December 2006
Resolved
Provide oil transfer procedures prior to transfer or bunkering
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: OTP o/b
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 4 December 2006
Resolved
Provide fuel oil containment prior to operating.
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: new install
Documentation › Markings/Placards › Official Number (US)
Issued 4 December 2006
Resolved
Provide official number permanent on vessel frame
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: Pin punch on port ER fwd blkhd
Communications › Audible Communications › Bell
Issued 4 December 2006
Resolved
Provide bell of proper size prior to operating.
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: 8 inch bell aft deck
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 4 December 2006
Resolved
Prove operation of galley fire detection
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: replaced galley detector-test SAT