MICHAEL C

MICHAEL C is a 1966 towing vessel. The Coast Guard has recorded 19 inspections since 2005, most recently in July 2026, along with 28 deficiencies and 1 operational control.

Records from 2005 to 2026. Most recent: inspection, 1 July 2026.

Built
1966
Last inspected
1 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 1 July 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 12 calendar years (2005–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WX7216
Flag
UNITED STATES
Maury page id
psix-90654

Documentation record

Registered dimensions (L × B × D)41.9 ft × 12.4 ft × 6.6 ft
Registered tonnagegross 22 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMADISONVILLE, LA, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 2 October 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

A N TILLETT Towing Vessel · MISLE 157441 · 28 October 2012 · activity 4503574SKOOKUM Towing Vessel · MISLE 85825 · 21 January 2009 · activity 3400482NORSEMAN Industrial Vessel · MISLE 208446 · 21 January 2009 · activity 3400482C M C-35 Freight Barge · MISLE 45347 · 29 June 2006 · activity 2752504

Inspection history · 19

1 July 2026 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8413737
14 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8185764
19 August 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7984884
30 July 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7970039
21 September 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7795914
14 September 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7558904
1 April 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7422974
29 June 2021 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7239265
28 October 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4503574
21 January 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3400482
26 September 2008 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3333384
25 September 2008 Administration · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3332752
17 March 2008 In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3164236
21 February 2008 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3151103
12 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2871059
29 June 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2752504
4 January 2006 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2560486
8 November 2005 Uninspected Other
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2531275
14 April 2005 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2334058

Deficiency record · 28

09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 1 July 2026 Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. This is not meant to restrict access to towing equipment such as winches, drums, towing gear or steering compartment equipment necessary for the operation of the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2026
Resolved 23 July 2026
Resolution: Received photos of 2 machinery guards installed. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 July 2025 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Vessel Port MDE did not start. Fix issue and notify local OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 July 2025
Resolution: [name withheld] attended vessel to conduct def check. All SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 July 2025 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Bilge system was not operating properly and light indicator for the engine room was inoperable. Fix issues and notify local OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2025
Resolution: [name withheld] attended vessel to conduct def check. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. 05 open breaker slots on the breaker panel on the bridge. Properly enclose open breakers and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 15 July 2025
Resolution: [name withheld] attended vessel to conduct def check. All SAT.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 July 2025 Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crew members are capable of performing the duties expected of them during emergencies. This includes abandoning the vessel, recovering persons from the water, responding to onboard fires and flooding, or responding to other threats to life, property, or the environment. Vessel was unable to get underway to conduct drills. Once vessel is ready for drills notify local OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2025
Resolution: [name withheld] attended vessel to conduct def check. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. MI found dead-end wires in the wheel house, under the helm. Update electrical plan and notify local OCMI once corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 15 July 2025
Resolution: [name withheld] attended vessel to conduct def check. All SAT.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 14 July 2025 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz, in addition to the VHF-DSC radiotelephone installation required by paragraph (a)(1) of this section. Vessel is missing the required MF-DSC frequency transmitter. Vessel is restricted to operating less than 20 nautical miles until MF-DSC frequency transmitter is installed in vessel. Notify local OCMI once corrected. 47 CFR 80.905
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 15 July 2025
Resolution: [name withheld] attended vessel to conduct def check. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 September 2022 Resolved
Vessel's pre engineered fire extiguishing system shall be serviced annually.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 September 2023
Resolution: Verified during the annual inspection
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 29 June 2021 Resolved
Operating Station installed VHF-FM RDO not able to produce DSC functions during operational testing. Whenever radiotelephone capability is required by this Act, a vessel's radiotelephone equipment shall be maintained in effective operating condition.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2021
Resolved 23 July 2021
Resolution: Received documentation / specs of new installed radio verifying satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 29 June 2021 Resolved
Forward storage room bulkhead penetration not properly sealed. Remove or cap penetration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2021
Resolution: Capped
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 29 June 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 June 2021 Resolved
Provide Drug and Alcohol management program information.
Action required: 10 - Deficiency Rectified
Resolved 29 June 2021
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 29 June 2021 Resolved
Hydraulic steering system not outfitted with hydraulic low level fluid alarm. Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2021
Resolution: Received Documentation of corrected deficiency.
Documentation › Certificates/Documents › FCC SSL
Issued 17 March 2008 Resolved
Provide proof of FCC SSL.
Condition: Unknown
Due 18 March 2008
Resolved 18 March 2008
Resolution: Provided proof of FCC SSL
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 March 2008 Resolved
Provide proof of a chemical testing program.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 7 April 2008
Resolution: Received proof of a chemical testing program and conducted satisfactory DAPI spot check for vessel.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 8 November 2005 Resolved
Provide fire detection system IAW 56 CFR 27.203
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2006
Fire Fighting › Fire Main › Condition
Issued 8 November 2005 Resolved
Provide fire main system IAW 46 CFR 27.301
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel installed a fire main system.
Fire Fighting › Fire Pumps › Location
Issued 8 November 2005 Resolved
Provide fire pump IAW 46 CFR 27.301
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel provided a fire pump.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Service
Issued 8 November 2005 Resolved
Provide currently serviced portable/semi-portable fire extinguishing systems on vessel IAW 46 CFR 27.303
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel provided current serviced fire extinguishers.
Lifesaving › Hand Flares › Expired
Issued 8 November 2005 Resolved
Provide current visual distress signals IAW 33 CFR 175.110
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2005
Resolution: Vessel has current visual distress signals onboard.
Lifesaving › Inflatable Liferafts › Servicing
Issued 8 November 2005 Resolved
All lifesaving equipment must be in good and serviceable condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: All lifesaving equipment is in good and serviceable condition.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 November 2005 Resolved
Provide correct vessel name on life buoy
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel stenciled vessel''s name on life buoy.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 8 November 2005 Resolved
Provide at least 2 properly licensed persons if the vessel is operated more than 12 hours in any 24 hour period IAW 46 cfr 15.610
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel has proper licensed persons.
Communications › Radio Communications › EPIRB
Issued 8 November 2005 Resolved
Provide a category 1 406MHz EPIRB IAW 46 CFR 52.26-20
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2005
Resolved 22 November 2005
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 8 November 2005 Resolved
Provide an echo depth-sounding device IAW 33 CFR 164.72
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 November 2005
Resolution: Vessel has a echo depth-sounding device onboard.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 November 2005 Resolved
Provide emergency fuel shut-offs operable from outside the fuel tank space IAW 46 CFR 27.207
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel installed fuel shut-offs outside the fuel tank space.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 November 2005 Resolved
COD expired. Provide valid COD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel has current COD.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 November 2005 Resolved
Provide a Type I lifejacket for each person on board stowed in a readily accessible space, in accordance with 46 CFR 25.25-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2005
Resolution: Vessel provided proper Type I lifejackets.