MISS JENNIFER

MISS JENNIFER is a 1978 towing vessel. The Coast Guard has recorded 22 inspections since 1993, most recently in August 2025, along with 30 deficiencies, 1 operational control and 2 casualty investigations between 2007 and 2008.

Records from 1993 to 2025. Most recent: inspection, 13 August 2025.

Built
1978
Last inspected
13 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 13 August 2025
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 16 calendar years (1993–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG9329
158765
Flag
UNITED STATES
Maury page id
psix-158765

Documentation record

Registered dimensions (L × B × D)45.0 ft × 18.1 ft × 7.4 ft
Registered tonnagegross 42 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOUIS G ORTIS BOAT CO · KROTZ SPRINGS, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTSMOUTH, VA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

W-10 Freight Barge · MISLE 51914 · 18 July 2008 · activity 3302966W-10 Freight Barge · MISLE 51914 · 7 April 1997 · activity 169536

Inspection history · 22

13 August 2025 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8204388
16 August 2024 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7974887
30 May 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7922617
12 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7740875
16 June 2022 COI Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7479372
10 February 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7138659
26 October 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7084116
5 August 2019 Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6773598
10 July 2018 Industry Initiated Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6464089
2 June 2011 MTSA Verification · Deficiency Check · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4033047
25 October 2010 Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 3878580
28 July 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3282052
18 July 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3302966
7 March 2007 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2883695
7 March 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2883748
7 March 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2895177
11 October 2006 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2798714
22 February 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2589979
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979795
18 September 2003 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1929636
7 April 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 169536
6 December 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 644885

Deficiency record · 30

11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 August 2024 Resolved
46 CFR 199.70(c)(4)(i): Each immersion suit must have a light approved under approval series 161.112 securely attached to the front shoulder area of the immersion suit or anti-exposure suit. All six immersion suits are missing lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2024
Resolved 28 August 2024
Resolution: Received photographic proof of affixed water lights to immersion suits.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 May 2024 Resolved
Crop and renew aft bulkhead in port potable water tank.
Action required: 705 - Other - as specified
Resolved 8 July 2024
Resolution: Approved C/R.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 July 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel's forepeak bilge suction pipe is corroded causing the pipe to be unfit for intended use. 46 CFR 143.205
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: New pump and piping installed in forepeak. Operational test complete. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 July 2023 Resolved
Repairs and minor alterations to existing towing vessels must be made in accordance with this part. New installations that are not replacements in kind must comply with the requirements of subpart C of this part, if applicable. Bilge suction in engine room is fitted with flexible tubing not in kind with original design. 46 CFR 143.205(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: Engine room flexible bilge piping was replaced with hard pipes. Operational test conducted, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 July 2023 Resolved
A towing vessel must carry a combination of day and night visual distress signals indicated in Table 141.370 of § 141.370 for specified areas where the vessel operates. Vessel was missing 4 day and 2 night distress signals. 46 CFR 141.375(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: O/O provided 6 day and 6 night distress signals in watertight container labeled distress signals. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 July 2023 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessels port side generator and main engine cooling water expansion tank level alarms were inoperable. 46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: MIs witness test of port side generator and main engine cooling water expansion tank level alarms, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 July 2023 Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. None of the immersion suits on board were marked with vessels name or person. 46 CFR 199.70(c)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: All immersion suits on board were marked appropriatley, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 July 2023 Resolved
At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Port side lifebuoy floating electric water light was to have the incorrect battery installed. 46 CFR 141.360(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: O/O installed proper floating water light battery into port ring buoy light, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2023 Resolved
Each lifejacket must be marked: In block capital letters with the name of the vessel. Vessels operating station lifejacket was found unmarked with vessels name. 46 CFR 141.340(f)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: Operating station life jacket marked properly, all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 July 2023 Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank,and is fitted with a 30-by-30-mesh corrosion-resistant flame screen. Vessels fuel tank vent mesh is not the correct size. 46 CFR 143.265(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2023
Resolved 3 August 2023
Resolution: Vessels fuel tank vent mesh screen was replaced with proper vent mesh, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 12 July 2023 Resolved
In addition to the immersion suits required under paragraph (a)(1) of this section, each watch station, work station. Vessel was missing 1 immersion suit. 46 CFR 141.350(a)(2)
Action required: 10 - Deficiency Rectified
Due 26 July 2023
Resolved 12 July 2023
Resolution: Vessel representative brought on an additional immersion suit before completion of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 June 2022 Resolved
The STBD main engine RPM gauge must be at the machinery location. STBD gauge missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 28 June 2022
Resolution: Operator installed gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 June 2022 Resolved
The Port main engine RPM gauge must be at the machinery location. Port gauge missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 28 June 2022
Resolution: Operator installed gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 June 2022 Resolved
The STBD generator RPM gauge must be at the machinery location. STBD gauge missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 28 June 2022
Resolution: Operator installed gauge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 June 2022 Resolved
The Port generator RPM gauge must be at the machinery location. Port gauge missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 28 June 2022
Resolution: Operator installed gauge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 June 2022 Resolved
Fire hose nozzle must be capable of providing a solid stream and a spray pattern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2022
Resolved 28 June 2022
Resolution: Operator purchased vary nozzle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2022 Resolved
Machinery must be designed to provide for safe operation, bilge pump not mounted to frame, suspended by bilge piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 28 June 2022
Resolution: Operator installed mounting plate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 October 2020 Resolved
There must be an installed or portable bilge pump for dewatering. Both bilge pumps were seized. Show evidence of an operating bilge pump in presence of Marine Inspector (MI) prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Installed new bilge pump and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 October 2020 Resolved
Towing vessel (T/V) must be equipped with a means to detect smoke in the berthing spaces. The smoke detector was inop. Replace/repair and test in presence of a MI
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2020
Resolution: Replaced batteries and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 October 2020 Resolved
An exposed hazard such as gears & rotating machinery, must be protected by a cover. Both genset prime movers pulleys were missing a cover. Install cover and test run
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2020
Resolution: Installed covers correctly
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 26 October 2020 Resolved
Each T/V must be equipped with an industrial type first aid kit. The first aid kit was missing most supplies. Replace kit with a new one.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2020
Resolution: Purchased new kit and mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 October 2020 Resolved
Each T/V must be maintained & operated so as to minimize fire hazards. The dryer vent was venting to the E/R bilge. Ensure vent trap is vented to atmosphere or contained.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2020
Resolution: Installed lint trap.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 October 2020 Resolved
Machinery systems must be designed and maintained to provide for safe operation of the towing vessel. The steering ram securing pins were missing cotter pins in the pre-drilled holes. Place cotter pins and test system
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2020
Resolution: Cotter pins installed correctly.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 26 October 2020 Resolved
Each T/V must have a reliable means to provide notification when an emergency exist. The bilge level alarm was not secured and moving around. Secure float with proper mounting hardware.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2020
Resolution: The level alarm was mounted with second securing bolt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 26 October 2020 Resolved
The following systems must be equipped with gauges at the machinery location: Hydraulic steering fluid psi. The gauge was missing, install gauge and test.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 December 2020
Resolution: Installed new gauge
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 October 2020 Resolved
The tablet for logging the TVR entries was missing. Begin logging properly IAW regulations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2020
Resolution: Replaced tablet and secured with lanyard.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 26 October 2020 Resolved
A garbage pollution placard must be installed to notify reader of operating requirements. The placard was out of date. Install new placard in the galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2020
Resolution: The placard was installed near the liferaft station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 October 2020 Resolved
Lifebuoys must have the attachments IAW regs. The waterlight line was over 50' in length and the lifeline was missing. Replace line for inspection by MI.
Action required: 10 - Deficiency Rectified
Resolved 26 October 2020
Resolution: Vessel crew repaired defs prior to departure by shortening waterlight line and installing a lifeline.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 August 2019 Resolved
Generator missing RPM gauge. Owner stated engine will not allow for a RPM gauge and will file for appeal.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2019
Resolved 13 April 2022
Engineering › Steering Gear System › Rudder
Issued 7 March 2007 Resolved
Repair/replace rudder that sustained unknown damage.
Action required: 705 - Other - as specified
Resolved 17 May 2007

Casualty record · 2

7 March 2007Routine · role: Involved in a Marine Casualty · activity 2895177
18 July 2008Routine · role: Involved in a Marine Casualty · activity 3302966
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

COYA N (2007–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.