Records from 2020 to 2026. Most recent: inspection, 11 July 2026.
Inspection history · 25
11 July 2026
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8431317
12 January 2026
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8295065
10 January 2026
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8293887
28 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8196352
13 July 2025
Deficiency Check · PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8184321
11 January 2025
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8059954
23 September 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8008488
8 September 2024
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7998583
14 July 2024
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7957643
21 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7939868
10 February 2024
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7853307
4 December 2023
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833362
16 July 2023
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7739593
14 January 2023
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7621412
16 July 2022
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7505432
14 January 2022
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7380619
8 January 2022
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7379321
2 October 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7332091
27 September 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7331173
4 September 2021
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7336369
3 August 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7277652
22 July 2021
PSC A · COC-CVE Initial
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7231467
8 June 2021
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7218634
7 June 2021
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 7218203
25 June 2020
COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 6986277
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 July 2025
Resolved
lectrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. Due to an accidental ESD activation, ventilation was shut down and condensation accumulated in the area leading to electrical wiring to become saturated.
74 SOLAS 20 II-1/40.1.3
16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2025
Resolved 21 July 2025
Resolution: Vessel submitted class report attesting to the repairs.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 July 2025
Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. Vessel was found to have storage in a catagory 2 space by fire door 6.2.03.
74 SOLAS 20 II-2/13.1.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 July 2025
Resolved 13 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 July 2025
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, or where it is possible to assign two or more classifications to a space, it shall be treated as a space within the relevant category having the most stringent boundry requirements. PSCO observed storage of flammable liquids inside the galley workshop.
74SOLAS 20 II-2/9.2.2.3.2.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 July 2025
Resolved 13 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2025
Resolved
A fixed fire detection and fire alarm system shall be so installed and arranged as to provide smoke detection in service spaces, control stations and accomodation spaces, including corridors, stairways and escape routes within accomodation spaces. When tsting smoke detectors in crew galley smoke detector 156.058 was found inoperational.
74 SOLAS 20 II-2/7.5.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 July 2025
Resolved 13 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 July 2025
Resolved
Detectors fitted in cabins, when activated, shall also be capable of emitting, or cause to be emitted, an audible alarm within the space where they are located. When tsting smoke detector in room 11470, audible alarm did not sound.
74 SOLAS 20 II-2/7.5.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 July 2025
Resolved 13 July 2025
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 July 2025
Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance is a fire accurs: structural fire protection including fire resisting division. A galley roller shutter in the Chibang restaurant deck 8 zone 3 was found blocked by food trays.
74 SOLAS 20 II-2/14.2.1.1.1
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 July 2025
Resolved 13 July 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 September 2024
Resolved
The transitional source of emergency electrical power required by paragraph 3.1.3 shall consist of an accumulator battery suitably located for use in an emergency which shall operate without recharging while maintaining the voltage of the battery throughout the discharge period within 12% above or below its nominal voltage and be of sufficient capacity and so arranged as to supply automatically in the event of failure of either the main or emergency source of electrical power. On September 07, 2024 the vessel self-reported a malfuncion with the UPS in MVZ1 with no root cause diagnosed for the incident.Consumers are not currently receiving transitional power.
74SOLAS20II-1/42.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2024
Resolved 22 September 2024
Resolution: Vessel submitted class report by LR attesting to the repairs of the UPS units.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 July 2023
Resolved
11131- Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. The second lifeboat commander on lifeboat #5 could not demonstrate how to start or operate lifeboat #5. 74 SOLAS 20 III/19.2.1 Code:10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 16 July 2023
Resolved 16 July 2023
Resolution: Vessel switched the second lifeboat commander from lifeboat #5 with an experienced commander.