Records from 2020 to 2026. Most recent: inspection, 31 May 2026.
Inspection history · 17
31 May 2026
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8381162
15 March 2026
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8326421
6 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8321071
6 March 2026
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8324055
29 September 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8243082
28 March 2025
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8093172
4 January 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8057413
4 January 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8064518
21 December 2024
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8047395
31 May 2023
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7698403
18 November 2022
Deficiency Check · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7596877
18 November 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7596922
10 November 2022
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7592529
24 October 2022
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7583176
20 April 2022
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7428026
7 December 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7107679
13 July 2020
PSC A · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7005074
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 January 2025
Resolved
74 SOLAS (20) II-1/3-1
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI-1/1, or with applicable national standards of the Administration which provide an equivalent level of safety.
PSCO received report from VTS and shipping agent that T/V PEARL COAST stern collided portside with M/V EVER FOCUS. Structural and mechanical integrity are unclear this this time due to indentation/warping of hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 January 2025
Resolution: It is recommended that the affected area be re-examined and dealt with to the satisfaction of the next attending surveyor prior to crediting the
vessel's next drydocking survey.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 November 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Received notification from vessel's master stating that the vessel lost power while moored at Seagirt Marine Terminal in the port of Baltimore. Chief engineer stated that #2 MDG tripped due to high temperature and air was found in the MDG's cooling water line.
74SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 November 2022
Resolved 19 November 2022
Resolution: Received Class Survey Report attesting to proper repair of faulty equipment.