Records from 2020 to 2025. Most recent: inspection, 10 December 2025.
Documentation record
Registered dimensions (L × B × D)52.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 5 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA&M MANUFACTURING INC · CHIEFLAND, FL, UNITED STATES · built 2020
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portMARATHON, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
10 December 2025
COI Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8277646
13 December 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8047272
10 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8044222
11 December 2023
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7942706
5 December 2022
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7604125
28 May 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7504554
17 February 2022
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7400100
1 November 2021
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7343462
30 July 2021
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 7277975
14 December 2020
Type not recorded
No type recorded · Station Marathon · USCG Southeast District (CGD-SE) · Activity 7111167
28 September 2020
Plan Review "T" Boat · DAPI Audit · Initial Certification · Construction Oversight · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7071934
11 August 2020
Administrative Inspection · Construction Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7058585
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 13 December 2024
Resolved
The words "FIRE BUCKET" must be stenciled in contrasting color on each bucket. Buckets only say FIRE.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2024
Resolved 13 December 2024
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 December 2024
Resolved
Alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred. Alcohol swabs are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2024
Resolved 16 December 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 December 2024
Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at operators station to indicate a high water level in unmanned spaces. Repair visual alarms on both port and STBD alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2024
Resolved 16 December 2024
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 13 December 2024
Resolved
Provide Marine Inspector with a copy of a FCC
operators license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 January 2025
Resolved 23 December 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 December 2022
Resolved
First aid kit had several expired items. Must have first aid kit the meets requirements in 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2023
Resolved 8 December 2022
Resolution: New first aid kit meeting all requirements on board.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 December 2022
Resolved
Supervisor is missing the EAP requirements for 1 hour EAP training. Complete training and provide documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2023
Resolved 8 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 December 2022
Resolved
Life raft needs repairs/repainting and missing the vessel's name and passenger count. Make repairs/repaint and then label with vessel's name and passenger count.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2023
Resolved 13 March 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 November 2021
Resolved
Missing crew training log. Must make a crew training log for each employee and then for any new hire.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2021
Resolved 8 December 2021
Resolution: Verified crew training logs.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 November 2021
Resolved
Missing log for testing EPRIB and inspecting survival craft monthly. Provide proof of monthly testing of EPRIB and monthly inspection of survival craft.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2021
Resolved 8 December 2021
Resolution: Vessel found missing log and verified monthly test