Records from 2011 to 2026. Most recent: inspection, 27 April 2026.
Inspection history · 20
27 April 2026
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8310043
6 January 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8278227
26 February 2025
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8072504
30 May 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7925985
10 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7847486
7 February 2023
DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7633485
9 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7618335
28 May 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7504554
1 February 2022
DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7389406
21 April 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7180523
9 April 2021
Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7172004
27 January 2021
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7131864
23 January 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6880566
24 January 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6614404
14 December 2018
COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6596993
15 March 2018
Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6371871
25 December 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6441438
27 August 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294423
30 January 2017
Deficiency Check · Hull Examination · Internal Structural Exam · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6112937
25 February 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5818774
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2026
Resolved
Replace 03 child life jackets.Vessel can only carry as many children as jackets are on vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 February 2025
Resolved
1 package of 3 red flares has expired. Replace expired flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2025
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 April 2021
Resolved
Vessel does not have a CG approved NAV chart onboard. Since vessel does not have a GPS with electronic charts, vessel must have a CG approved updated CG approved NAV Chart onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 30 April 2021
Resolution: Received pictures of new paper NAV chart for local operating area
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 April 2021
Resolved
Both life floats are faded and need repainting with new retro tape to replace faded/worn out retro. Must repaint using approved paint and install new SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 19 May 2021
Resolution: Received pictures on both life floats painted, labeled and new retro tape. All SAT
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 April 2021
Resolved
Both port and STBD 12V engine batteries are not secured to hull to prevent moving around. Must secure both batteries to hull to prevent any movement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 19 May 2021
Resolution: Received pictures of batteries secured to hull, all SAT
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 April 2021
Resolved
First aid kit did not have the proper strenght asprin. Must replace with proper strenght to meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 30 April 2021
Resolution: Received picture of new first aid item with experation date of Jan 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2021
Resolved
Several life jackets had worn or peeling retro tape. Must replace retro tape on all life jackets that were called out and marked with X
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2021
Resolved 29 April 2021
Resolution: Added new retro tape to all life jackets called out before end of inspection. All SAT
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 April 2021
Resolved
High water bilge alarm would not work. Must make repaires and test to satisfaction attending CG Marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2021
Resolved 29 April 2021
Resolution: Cut out 6 inches of bad wire and re connected to alarm switch on helm station. Test SAT
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 April 2021
Resolved
Vessel failed to have its Annual inspection completed within time frame required. Vessel must conduct a COI inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2021
Resolved 29 April 2021
Resolution: Conducted COI inspection and DAPI audit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2020
Resolved
Repair/replace reflective tape on 2 Adult and 06 Child PFDs, tape was found damaged and not reflective.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2020
Resolution: Retroreflective tape replaced, PFDs cleaned
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 January 2020
Resolved
Post sign stating “Official Documents available upon request”, vessel does not have adequate bulkhead space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2020
Resolution: Sign posted
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 January 2020
Resolved
Provide GPS input and MMSI# into installed VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 January 2020
Resolution: New VHF radio installed
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 24 January 2019
Resolved
Crack found on forward cross-member. Grind down to good glass and repair in accordance with original layup schedule IAW NVIC 8-87.
Action required: 705 - Other - as specified
Resolved 25 January 2019
Resolution: PRIOR TO CREDIT DRY DOCK
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2019
Resolved
Numerous blisters and sections of exposed glass found on each hull. Sand hull down to expose blisters, allow to dry out prior to repair. Remove damaged FRP and replace IAW with NVIC 8-87.
Action required: 705 - Other - as specified
Resolved 25 January 2019
Resolution: PRIOR TO CRDIT DRY DOCK
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 December 2018
Resolved
Post all pages of COI and Stability Letter or post placard stating “Official Documents available upon request".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 December 2018
Resolved
Provide documentation that shows pre-employment drug testing of all current crew members.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Up to date list provided.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 14 December 2018
Resolved
Update emergency instructions placard utilizing federal recommendations in CFR.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 December 2018
Resolution: New instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 December 2018
Resolved
Provide waterlight and paddles for 6 person lifefloat, line connection light to float shall be 18ft.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Paddles and waterlight provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 December 2018
Resolved
Mark lifefloat with approved passenger count (6) and provide means to separate stacked lifefloats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Item corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2018
Resolved
When Child and Adult PFDs are stowed in the same space means must be provided to clearly separate them.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Adequate means provided for separation.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 December 2018
Resolved
Provide first aid kit that has all contents per 46 CFR 160.041.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: New first aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 December 2018
Resolved
Provide current required publications (Light list, Tide tables, US Coast Pilot [name withheld]).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 December 2018
Resolution: All required pubs on board.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 December 2018
Resolved
Replace hydrostatic release for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 December 2018
Resolution: New hydrostatic release installed.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 14 December 2018
Resolved
Provide GPS input for VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 December 2018
Resolved
Raise all around white navigation light, stacked life floats block 360* view.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 14 December 2018
Resolved
Demonstrate proper operation of STBD aft overboard discharge positive shutoff valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 14 December 2018
Resolved
Make all penetrations to Port and STBD transoms watertight, opening for engine controls is not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 December 2018
Resolved
Replace all gasoline fuel lines and fuel filters from tank to outboards.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 December 2018
Resolved
Electronically bond fuel tanks to the vessels common ground.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 14 December 2018
Resolved
Secure Marine Sanitation Device "Y" valve to prevent accidental sewage overboard discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Y valve secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 December 2018
Resolved
Secure battery boxes from shifting from the pitch and roll of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2019
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 14 December 2018
Resolved
Repair forward part of soft canopy structure and repair/replace fasteners for securing to hard canopy.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 December 2018
Resolution: Canopy repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 December 2018
Resolved
Submit plans to local OCMI to provide adequate ventilation to Port and STBD hulls. Batteries are installed on both Port and STBD hulls.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2019
Lifesaving › Hand Flares › Quantity
Issued 15 March 2018
Resolved
Missing 1 flare. provide new orange or red hand flare.
Action required: 705 - Other - as specified
Due 16 March 2018
Resolved 16 March 2018
Resolution: Corrected on spot
Navigation › Piloting/Steering › Magnetic Compass
Issued 15 March 2018
Resolved
compass light is extinguished. repair/renew
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: Compass light was rewired and tested all sat.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 15 March 2018
Resolved
port fuel tank fill is missing hose clamp & ground wire.
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: new hose clamps were installed.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 15 March 2018
Resolved
STBD fuel tank ground wire is incorrect. mount from fill (metal) to tank ( Metal)
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 29 March 2018
Resolution: New ground wires were installed.
Lifesaving › Hand Flares › Quantity
Issued 27 February 2017
Resolved
Vessel is missing 3 orange smoke flares.
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 3 March 2017
Resolution: New flares were provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 27 February 2017
Resolved
Vessel is missing one BI fire extinguisher.
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 3 March 2017
Resolution: New extinguisher was provided.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 27 February 2017
Resolved
STBD fuel tank vent hose is too short and is disconnected. Renew hose.
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 3 March 2017
Resolution: Hose was renewed and grounded per the CFR.
Lifesaving › Lifebuoys › Size
Issued 27 February 2017
Resolved
Life Ring Buoy is the incorrect size. Renew it with the correct approved size.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 3 March 2017
Resolution: New 24" life ring was provided and properly marked.
Navigation › Piloting/Steering › Magnetic Compass
Issued 27 February 2017
Resolved
Vessel compass light is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 3 March 2017
Resolution: Compass light was renewed and tested all sat.