SHARKBAIT

SHARKBAIT is a 1978 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in January 2026, along with 66 deficiencies, 1 operational control and 2 casualty investigations between 2007 and 2012.

Records from 2007 to 2026. Most recent: inspection, 27 January 2026.

Built
1978
Last inspected
27 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP4243
Flag
UNITED STATES
Maury page id
psix-49648

Documentation record

Registered dimensions (L × B × D)33.7 ft × 13.6 ft × 6.3 ft
Registered tonnagegross 20 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderENSIGN YACHTS · FORT LAUDERDALE · built 1978
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPOMPANO BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
13 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

27 January 2026 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8302093
19 June 2025 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8162557
22 April 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8116715
24 April 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7900890
23 January 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7858374
19 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7851777
16 March 2023 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7651751
3 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7442965
23 November 2021 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7358348
20 January 2021 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7131500
20 July 2020 Administrative Inspection · Annual Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7011515
15 October 2019 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6790757
23 May 2019 Deadweight Survey · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6674404
25 April 2018 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6398077
25 September 2017 Hull Examination · Internal Structural Exam · Deficiency Check · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293524
20 April 2017 COI Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6128525
13 June 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5911916

Deficiency record · 66

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2025
Resolution: Vessel completed all repairs in accordance with their 835. New activity created for COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2025 Resolved
46 CFR 181.420(a)(3) A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The engine did not shut down upon disconnection of the fire extinguishing system.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2025
Resolution: MI completed satisfactory test of engine shut down.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 April 2025 Resolved
46 CFR 179.360(a) A hatch exposed to the weather must be watertight. Three exposed hatches on the deck were wasted and missing gaskets and captive chains. Hatches must be sealed and fully functional.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 19 June 2025
Resolution: Captive chains installed on hatches.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 April 2025 Resolved
46 CFR 182.530(a)(2) On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces… A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. The visual alarm indicator to the high level bilge alarm did not work and location was not identified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 22 May 2025
Resolution: MIs verified visual alarm indicator to the high level bilge alarm onboard the vessel.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 April 2025 Resolved
46 CFR 182.520(a) Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. The central control point had no visual indicator during bilge pump operation and was missing an identifying label.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 22 May 2025
Resolution: MIs verified visual indicator during bilge pump operation at the central control point.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2025 Resolved
46 CFR 180.68(a) A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry six hand red flare distress signals… and six hand orange smoke distress signals. Three smoke distress signals were expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 22 May 2025
Resolution: MIs confirmed new replacements of smoke destress signals while onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 April 2025 Resolved
33 CFR 83.30(a)(i) A vessel at anchor shall exhibit where it can best be seen in the fore part, an all-round white light. The anchor light did not turn on when tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 22 May 2025
Resolution: MIs confirmed proper operation of the vessel's anchor light.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 April 2025 Resolved
46 CFR 182.15-40(b)(5) A suitable metal marine type strainer shall be fitted in the fuel supply line in the engine compartment...A drip pan fitted with flame screen shall be installed under the strainer. Flame bowls/drip pans were not found under the fuel strainer.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 22 May 2025
Resolution: MIs verified drip pan installed under the fuel strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2025 Resolved
46 CFR 185.604(b) Each life jacket… must be marked in clearly legible block capital letters with the vessel's name. Several life jackets were missing the vessel’s name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 19 June 2025
Resolution: Vessel name stenciled on all jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2025 Resolved
46 CFR 185.604(h) Each life jacket must be marked with Type I retroreflective material. 13 life jackets were missing Type I reflective material.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 19 June 2025
Resolution: All life jackets onboard outfitted with reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2025 Resolved
46 CFR 180.71(a) An adult life jacket must be provided for each person carried on board a vessel. The vessel carries up to 27 adults and had only 26 adult life jackets onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 19 June 2025
Resolution: Correct amount of life jackets obtained.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 April 2025 Resolved
46 CFR 181.610 A vessel not required to have a power driven fire pump by § 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. The vessel did not have any fire buckets onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 19 June 2025
Resolution: Fire buckets correctly stenciled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 April 2025 Resolved
46 CFR 176.802(a)(4) At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including: Inspection of all railings and bulwarks and their attachment to the hull structure. Forward port side handrails are missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 19 June 2025
Resolution: Handrail hardware installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must...Be capable of manual actuation from outside the space in addition to automatic actuation by a heat detector. 46 CFR 181.420 Found that the pre-engineered fixed gas system was not properly wired up since the last servicing completed in March of this year, deeming the system inoperable. Provide satisfactory tech report from local fire system servicing company.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2024
Resolved 13 May 2024
Resolution: Vessel provided tecnical report from Broward Fire for the proper operation of the pre-engineered fire system.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 May 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; 46 CFR 182.530 Found that the high water alarms had not yet been wired up due to the vessel awaiting the delivery of new high water sensors. Old, functioning high water alarm sensors shall properly be re-installed until new sensors arrive.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2024
Resolved 13 May 2024
Resolution: Previously installed high water sensors were re-wired and video eveidence was sent to display proper functionality of the high water alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 May 2024 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. 46 CFR 182.410(b) Found that none of the propulsion monitoring gauges had been wired up since overhaul of the vessel's wiring. Vessel shall complete wiring to include the gauges at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 25 June 2025
Resolution: All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 May 2024 Resolved
A hatch exposed to the weather must be watertight. 46 CFR 179.360(a) Found that the STBD side mid hatch had severe wastage that created a 1" hole to the engine compartment. Replacement of hatch cover is required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 25 June 2025
Resolution: All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 January 2024 Resolved
A vessel that is exposed to salt water more that three months in any 12 month period must undergo a drydock examination and an internal structural exam at least once every two years. Vessel did not start or complete DD/ISE prior to due date of 30Nov2023. 46CFR 176.600(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2024
Resolved 26 January 2024
Resolution: Vessel completed drydock and internal structural exam.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel's last COI inspection was on January 27th, 2021. The vessel is not permitted to operate until a satisfactory annual examination has been completed. 46 CFR 176.500 (b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2022
Resolved 5 May 2022
Resolution: Satisfactory annual completed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 27 January 2021 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR Part 40. (Ensure all crew is enrolled in drug consortium and provide documents of preemployment testing has been conducted. Ensure alcohol test strips are not expired.) 46 CFR 16.201 46 CFR 185.212
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2021
Resolved 2 February 2021
Resolution: Owner provided documentation showing all crew members are properly enrolled in a drug and alcohol program.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 January 2021 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge , Marine Inspection. (Forward bilge pump wiring needs to be ran under the deck to prevent damage when closing the hatch cover. Forward engine compartment has cable that is cut and exposed.) 46 CFR 183.01-15 (a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2021
Resolved 2 February 2021
Resolution: All wiring is properly ran under fwd compartment hatch and dead end cables are terminated.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 January 2021 Resolved
Provisions shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. (Have vent covers accessible for engine compartment in the event the fire suppression system is activated.) 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2021
Resolved 2 February 2021
Resolution: Vessel constructed vent covers out of a composite material.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 January 2021 Resolved
Vessels shall be inspected for compliance with standards required by this subchapter. For item not covered by the standards in this subchapter, inspections shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. (Cables and piping that penetrate the bulkheads need to be sealed to ensure watertight integrity is not compromised.) 46 CFR 176.25-1 (a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2021
Resolved 2 February 2021
Resolution: Marine grade sealant was used on all cable runs that penetrated the bulkheads.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2021 Resolved
Vessels shall be inspected for compliance with standards required by this subchapter. For item not covered by the standards in this subchapter, inspections shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. 46 CFR 176.25-1 (a) (Inspect all fitting throughout ship to ensure corrosion does not pose a threat to the material condition. Inspect corrosion on bottom of engine cooling system expansion tank. Inspectors will check again at deficiency check.)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2021
Resolved 2 February 2021
Resolution: Fittings were inspected to ensure stuctural integrity was sufficient.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 27 January 2021 Resolved
Every vessel subject to Part II or Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with part 80.59 of this chapter once every five years. (Radiotelephony Certificate is expired.) 47 CFR 80.901
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2021
Resolved 2 February 2021
Resolution: Certificate provided via email.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 January 2021 Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. (Engine cooling water gauge in pilot house was not accurately displaying the temperature.) 46 CFR 182.20-5 (b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2021
Resolved 2 February 2021
Resolution: Vessel purchased and installed new sender unit and gauge for engine cooling water temperature.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 July 2020 Resolved
Visual light for high level alarm not working. Repair/renew
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 5 August 2020
Resolution: All visual alarms for high level alarms were rewired and verified to be in working order.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020 Resolved
Renew 03 adult and 04 child life jackets. No more than 21 adult persons and 00 children underway until life jacket have been renewed and verified on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 5 August 2020
Resolution: 03 adult and 04 child life jackets were purchased and appropriately placed into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020 Resolved
Renew reflective tape on 04 life jackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 5 August 2020
Resolution: Reflective tape on life jackets were renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 July 2020 Resolved
Renew all expired and or missing items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 5 August 2020
Resolution: A new first aid kit was purchased and placed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 July 2020 Resolved
Renew missing clip for life float light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2020
Resolved 5 August 2020
Resolution: Missing clip for float light was purchased and properly secured to the float light
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 July 2020 Resolved
Update Nav pubs with current addition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 5 August 2020
Resolution: All Nav Pubs have been updated with the current additions.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 July 2020 Resolved
Show proof of annual DAPI MIS report was submitted to Coast Guard for yr 2019.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 14 August 2020
Resolution: Provided copy of MIS report that was sent in
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 July 2020 Resolved
Conduct man overboard and fire drills and log as required.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 5 August 2020
Resolution: Logs have been created and verified for MOB and fire drills.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 July 2020 Resolved
Replace EPIRB with correct boat issued EPIRB or have Temp EPIRB changed to this vessel and log monthly test.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 14 August 2020
Resolution: Changed registration to EPRIB on vessel and replaced bracket to correct one.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 July 2020 Resolved
Renew or replace all life line stations called out during inspection by the end of next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 10 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 July 2020 Resolved
Engineroom bilge pump and alarm was not working. Conduct repairs or replace pump and alarm prior to carrying passengers to the satisfaction of attending CG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2020
Resolved 20 July 2020
Resolution: Replaced float switch before end of inspection and tested, tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2019 Resolved
Install new 205 gallon Port and STBD fuel tanks and associated piping. Make installation available for re-inspection prior to to installing deck.
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: installed
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 15 October 2019 Resolved
Provide repair plan for forward deck frame supporting shelf on STBD hull in way of forward compartment bulkhead. Frame was rotted and no longer supporting deck.
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Deck repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 October 2019 Resolved
Replace engine room deck frame on STBD side in way of BOMAR deck hatch. Frame was found wasted.
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Deck frame replaced
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 October 2019 Resolved
Replace Fireboy clean agent cylinder, cylinder was found with scaling rust. Fire Equipment servicing tech (Monroe County Fire) noted that cylinder should be replaced during annual inspection on April 2019.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 November 2019
Resolution: operated properly
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 October 2019 Resolved
Repair/replace deck frame shelf on STBD hull in Engine room compartment. Area indicated by attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Replace rubber shaft seal hose, rubber was deteriorating at shaft log.
Action required: 705 - Other - as specified
Resolved 23 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Replace forward cutlass bearing, bearing was worn down past 50%.
Action required: 705 - Other - as specified
Resolved 23 October 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Repair fiberglass exhaust tubing in Lazarette space, previous repair was delaminated.
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: replaced exhaust tubing
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 15 October 2019 Resolved
Repair swim platform on STBD side in way of recovery stern ladder. Platform was cracked at ladder connection point.
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: repaired swim platform
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 October 2019 Resolved
Demonstrate proper operation or replace raw water thru-hull gate valve. Valve would only close 20% of the way during inspection.
Action required: 705 - Other - as specified
Resolved 23 October 2019
Resolution: valve operational
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 October 2019 Resolved
Grind down five areas to good glass on outside hull that were marked by attending marine inspector. Repair delaminated glass, follow approved layup procedure.
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Hull sand blasted
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 October 2019 Resolved
Replace/repair aft deck following fuel tank installation, follow existing construction design(deck materials, frame spacing, fiberglass layup schedule).
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Deck replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 October 2019 Resolved
Repair and reinstall deck rail stanchions for aft deck, aluminum stanchions had corrosion near deck base.
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Deck rails installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 May 2019 Resolved
Replace positive shutoff valve for engine room submersible bilge pump overboard discharge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: valve replaced
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 May 2019 Resolved
Secure engine room penetration in aft bulkhead, space is protected with fixed fire extinguishing system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Bulkhead penetration secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019 Resolved
Vessel is restricted from utilizing STBD fuel tank, heavy corrosion observed on multiple areas of the tank. Secure all fuel supply valves to prevent use of tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Valve terminated and handle removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2019 Resolved
Remove corrosion around supply, return and vent connects on Port tank and conduct pressure test in the presence of a Marine Inspector, pressure shall be held at 5psi for 10 minutes with no leaks or replace tank. Complete by next credit drydock.
Action required: 705 - Other - as specified
Resolved 15 October 2019
Resolution: Fuel tanks replaced see activity #6790757
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019 Resolved
Replace cover for electrical conduit box in lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: cover replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 May 2019 Resolved
Remove all dead-end wiring and support wires at 18” intervals and supported as high practicable from bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 October 2019
Resolution: Wires removed and supports installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 May 2019 Resolved
Post all pages of Stability Letter
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 October 2019
Resolution: Stability letter posted
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 May 2019 Resolved
Provide updated US Coast Pilot, tide table, and currents for area of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Publications on board and up to date.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 April 2018 Resolved
A vessel with a pre-engineered fire extinguishing system must have a means to restart engines after shutdown. Demonstrate proper operation of override function.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2018
Resolution: Vessel purchased new override switch, installed and demonstrated proper operation to attending marine inspector.
Fire Fighting › Fire Bucket › Quantity
Issued 25 April 2018 Resolved
A vessel not required to have a fire pump must have three 2.5 gallon buckets with attached lanyard and the words "FIRE BUCKET" stenciled in contrasting color. Vessel has two buckets, provide one additional bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 April 2018
Resolution: Vessel provied additional 2.5 gallon bucket, attached lanyart and properly marked it.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 April 2018 Resolved
As appropiate for intended voyage, a vessel must carry adequate and up to date charts and nautical publications. Provide required publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 November 2019
Resolution: Vessel rectified deficiency.
Communications › Radio Communications › VHF Radiotelephone
Issued 25 April 2018 Resolved
DSC-VHF Radio must have MMSI programmed and a GPS input.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 November 2019
Resolution: Vessel Rectified Deficiency
Lifesaving › Lifefloat › Painter
Issued 20 April 2017 Resolved
Life float painter basket is broken, and could trap line not allowing life float to float free. Repair/renew.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 19 May 2017
Resolution: New painter basket was porovided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 April 2017 Resolved
Strobe light is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 19 May 2017
Resolution: New batteried were installed, and light was tested all sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 April 2017 Resolved
Reflective tape is missing on life ring. Replace.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 19 May 2017
Resolution: New SOLAS tape was applied.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 April 2017 Resolved
Compass light is extinguished. Repair/renew.
Action required: 705 - Other - as specified
Due 4 May 2017
Resolved 19 May 2017
Resolution: New compass was installed.

Casualty record · 2

28 December 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3121955
1 January 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4217003
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

LADY KEY DIVER (2007–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.