Inspection history · 29
3 June 2026
Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8390230
2 June 2026
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8390293
5 March 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8328828
10 December 2025
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8281656
4 November 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8262538
29 April 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8123635
29 April 2025
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8123850
5 March 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8085731
27 September 2024
Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8010562
14 March 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7879072
30 November 2023
In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7831932
10 October 2023
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7806175
9 January 2023
Annual Inspection · Deficiency Check · DAPI Audit · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7619533
26 November 2022
Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7599803
24 November 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7609575
18 April 2022
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7433281
11 April 2022
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7429034
24 February 2022
Administrative Inspection · Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7401494
21 February 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7421924
11 January 2022
Deficiency Check · Examination of Repairs · COI Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7378889
8 December 2021
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7364418
8 February 2021
Annual Inspection · Examination of Repairs · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7137883
14 January 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6884267
4 December 2019
Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6860527
17 December 2018
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6588555
11 December 2017
Hull Examination · Administrative Inspection · Annual Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6531543
27 September 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294431
12 January 2017
Internal Structural Exam · Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6069722
6 April 2016
Administrative Inspection · DAPI Audit · Annual Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5846810
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2026
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operationg at constant marine load under such requirements without exceeeding its designated limitations. Vessel must prove to marine insnsoector that cause has been repaired and repairs are satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2026
Resolved
STBD fuel shut off value has a broken handle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2026
Resolved
Vessel needs a new life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2025
Resolved
Life ring light does not work.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 10 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 March 2025
Resolved
Vessel is missing life jacket donning placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 10 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 March 2025
Resolved
Renew retro tape on the life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2025
Resolved 10 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 September 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel must prove to marine inspector that lower unit has been repaired and are satisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2024
Resolution: Conducted sea trial. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 January 2023
Resolved
Both life floats were black and needing cleaning/repainting. Must clean or repaint both life floats and replace SOLAS reflective tape and label with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 17 January 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 January 2023
Resolved
Missing monthly EPRIB test log. EPRIB must be tested and logged monthly.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 17 January 2023
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 January 2023
Resolved
Vessel is missing the Nav pub, COAST PILOT. Vessel must have on latest version of COAST PILOT for area of operation or all masters must know how to access it via the internet IAW NVIC 01-16
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2023
Resolved 17 January 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 November 2022
Resolved
Vessel had engine issues while underway with passengers and had to "limp" back to dock. Company swapped outboards. Must conduct satisfactory sea trials prior to carrying passengers.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2022
Resolution: Conducted satisfactory sea trials
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Vessel was involved in Marine Casualty. Must conduct damage survey prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2022
Resolution: Conducted damage survey, no damage found other than paint scraps. Cleared to operate.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 11 April 2022
Resolved
Vessel was noticed loading passengers today with the water line approx 6 inches below the surface of the water and the engine brackets were submerged in the water. Due to stability concerns, your max passenger count is 37 until a new stability test in conducted.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 26 April 2022
Resolution: New Stability test was conducted and passed for 34 passengers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 February 2022
Resolved
Vessel failed to notify CG when vessel ran hard aground. Must drydock vessel and have ready for CG inspection prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2022
Resolution: Conducted damage survey and no damage found.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 January 2022
Resolved
FCC Safety Certificate expired Feb 2021. Must show valid FCC Safety Certificate.
47 CFR 13
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 14 February 2022
Resolution: New FCC safety certificate was issued.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 January 2022
Resolved
EPIRB was found with battery that expired March 2021. Must replace battery and have it re certified.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 14 February 2022
Resolution: Brand new EPRIB was installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 January 2022
Resolved
Life ring buoy was found without vessels name and without retro tape on it. Must be labled with vessels name and have enough retro tape that meets the requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 14 February 2022
Resolution: Life ring had vessels name and all new retro tape.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 January 2022
Resolved
First aid kit had expired Asprin. Must replace Asprin to meet requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 14 February 2022
Resolution: New bottle of asprin put in first aid kit
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 January 2022
Resolved
27 adult life jackets were found with faded/worn retro tape. Must replace retro tape on all life jackets called out.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 14 February 2022
Resolution: 27 life jackets had retro tape replaced
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 January 2022
Resolved
Un able to show proof of fire, MOB drills and monthly EPRIB test. Must show proof of drills and monthly EPRIB test.
46 CFR 185.728
185.520
185.524
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 14 February 2022
Resolution: Logs were provided showing drills and monthly EPRIB test
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 January 2022
Resolved
Due to weather conditions, unable to get vessel underway and conduct fire & MOB drills. Must conduct drills within the next 30 days.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 24 February 2022
Resolution: Vessel underway and conducted satisfactory drills.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 January 2022
Resolved
Vessel was found with 2 gouges in STBD side hull at the stem. Must gouge out and repair damaged area.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 February 2022
Resolved 14 February 2022
Resolution: Damage was fixed and repaired back to normal.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 February 2021
Resolved
Mast light not working. Must make repairs prior to carrying passengers.
COLREGS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2021
Resolved 8 February 2021
Resolution: Received call and video of all NAV lights working.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 February 2021
Resolved
All 4 fire extinguishers annual inspection had expired. Must complete annual fire extinguisher service or buy new extinguishers prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2021
Resolved 8 February 2021
Resolution: 3 Fire extinguishers were brought over from thier 6 pack vessel that were serviced and current.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2021
Resolved
Life ring buoy was in bad shape, retro faded and grabe lines completely dry rotted. Must replace with new CG approved life ring prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2021
Resolved 8 February 2021
Resolution: Life ring was brougt over from there 6 pack vessel to replace bad one. Vessels name was marked on life ring
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 8 February 2021
Resolved
Bilge high water alarm visual signals are not nor have they ever been installed. Must install high water alarm visual signals at help station as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 2 April 2021
Resolution: Conducted a functional test of newly installed indicator lights and buzzer for Bilge high water alarm, equipment found in operation. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 February 2021
Resolved
Vessel did not have an approved CG NAV Chart onboard vessel. Nav chart vessel did have was old and no chart corrections made. GPS was not updated with current software version. Must have updated CG approved NAV Chart or update GPS to latest software version.
NVIC 1-16
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 23 February 2021
Resolution: Recieved picture of correct CG approved NOAA NAV Chart
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 February 2021
Resolved
Only NAV pubs vessel had onboard were the Navigation rules and 2018 version of light list. Must update all required NAV pubs onboard or download current digital copies.
NVIC 1-16
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 8 February 2021
Resolution: All required Nav pubs were downloaded to Captains phone from CG NAVCEN website
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 February 2021
Resolved
Vessel did not have crew training log, Fire drills not being logged and MOB drills not being logged properly. EPIRB test and life float inspections not being conducted monthly as required. Must hold crew training on new hires on all safety equipment of vessel prior to getting under for the first time and make crew training log and log all info as required, start logging fire and MOB drills correctly and conduct monthly EPIRB and life float inspections as required.
46 CFR 185.420
46 CFR 185 520
46 CFR 185.524
46 CFR 185.702
46 CFR 185.728
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 24 February 2021
Resolution: Received text with pictures of new logs with all required info for drills.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 8 February 2021
Resolved
Compass light is not working. Must make repairs to compass. Vessel is restricted to daylight hours only until repairs are completed and cleared by CG
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 22 February 2021
Resolution: Repaired compass light, test SAT
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 February 2021
Resolved
Company missing updated crews list and proof of pre employment drug test and proof of all employee's enrolled in drug consortium. Must provide all within 14 days
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 2 April 2021
Resolution: Owner/ Operator presented updated crew's list enrolled in drug consortium. All enrolled with ACPA. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 February 2021
Resolved
Alcohol swabs were missing. Must be able to provide alcohol test for entire crew if marine casualtly were to happen.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 February 2021
Resolved 22 February 2021
Resolution: Received new alcohol swabs, expire 31 Jan 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 February 2021
Resolved
Found 2 frames, one portside hull and other is STBD side hull, with tabbing delamination. Must conduct repairs to frames to satisfaction of attending CG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 March 2021
Resolved 11 May 2021
Resolution: Attended vessel and verified both sides were repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 14 January 2020
Resolved
EPIRB monthly tests need to be logged.
Action required: 10 - Deficiency Rectified
Resolved 24 February 2020
Resolution: tests logged
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 January 2020
Resolved
Magnetic compass must be illuminated - daytime ops only.
Action required: 705 - Other - as specified
Resolved 13 February 2020
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 January 2020
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2020
Resolution: extinguiser mounted on bracket and labled
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 January 2020
Resolved
Dead end wires need to be removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 January 2020
Resolved
Deck rails or equivalent protection must be installed near the periphery of all decks accessible to passengers or crew - submit plans for permanent fix to OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 December 2019
Resolved
Replace Port and STBD fuel tanks with tanks that meet listed requirements in 46 CFR 182.440-450. Submit plans to local OCMI for approval. Conduct pressure test of both Port and STBD fuel tanks in the presence of a Marine Inspector. Test shall use one of the following methods: (1)Attach a 11.5ft standpipe of at least 1-inch diameter to the tank and close all other fittings but the vent, tank shall be level during testing. Tank shall be filled until median pours out of tank vent to ensure no air is in tank and then cap vent. Hold pressure on tank for 10 minutes to check for signs of leakage. (2) Pressure tank with water using pressure regulator to 5 psi for 10 minutes.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 May 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 December 2019
Resolved
Repair all locations identified by Coast Guard Marine Inspector as well as self identified locations to good glass (attached to core material)and re-glass in accordance with original layup plan. Provide pictures to inspectors throughout the process (ground down and with new repair).
Action required: 705 - Other - as specified
Resolved 17 December 2019
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 December 2019
Resolved
Install rails around the outer deck of the vessel with a top rail height of at least 39.5 inches with rail courses no more than 4 inches apart.
Action required: 705 - Other - as specified
Resolved 17 December 2019
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 17 December 2018
Resolved
Post all pages of Stability Letter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 December 2018
Resolved
Post all pages of Certificate of Inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 December 2018
Resolved
Provide Drug Testing Program for inspection at follow up inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 December 2018
Resolved
Provide properly identified weak link for life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 17 December 2018
Resolved
Update life jacket storage container markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 17 December 2018
Resolved
Mount EPIRB in a float free location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
01 - Certificates & Documentation › 013 - Documents › Ship specific plans for the recovery of persons from the water
Issued 17 December 2018
Resolved
Update emergency instructions to reflect operations of vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 December 2018
Resolved
Provide current Coast Pilot and Light List or extracts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 December 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 December 2018
Resolved
Mount 40 BC fire extinguisher in CG approved bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 December 2018
Resolved
Reconnect fuel tank grounding wires to good metal
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 December 2018
Resolved
Weld starboard deck rail amidships in area indicated by the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 January 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 December 2017
Resolved
Bilge high level alarm light is extinguished. Repair/ renew.
Action required: 10 - Deficiency Rectified
Resolved 16 February 2018
Resolution: New alarm lights were installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 December 2017
Resolved
3 of the 4 compartments on the vessel do not have high level alarms. The alarms are required in each compartment because the hatches at the deck level are not water tight, and do not have a rised combing. Provide high level alarms in each compartment per 46 CFR 182.530(a)
Action required: 10 - Deficiency Rectified
Resolved 16 February 2018
Resolution: High level alarms were installed in all compartments on the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2017
Resolved
Vessel must have a log to track quarterly drills, EPIRB testing, and survival craft maintenance. Provide.
Action required: 10 - Deficiency Rectified
Resolved 16 February 2018
Resolution: New Log was created and is being utilized.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 December 2017
Resolved
Stern light bracket is broken and light is hanging by the wires. Repair/renew.
Action required: 10 - Deficiency Rectified
Resolved 16 February 2018
Resolution: Stern light was renewed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 December 2017
Resolved
Hatches need new seals, and dogs repaired.
Action required: 10 - Deficiency Rectified
Resolved 16 February 2018
Resolution: All hatches were resealed, and dogs either renewed, or adjusted.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 12 January 2017
Resolved
Vessel does not have alcohol test strips onboard.
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 26 January 2017
Resolution: New test strips were provided.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 12 January 2017
Resolved
Vessel does not have drill logs.
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 26 January 2017
Resolution: New log has been created and all drill will be logged every 3 months.