Records from 1990 to 2008. Most recent: inspection, 26 September 2008.
Inspection history · 22
26 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3333284
13 September 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3434954
21 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2342167
8 July 2004
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2125806
20 August 2003
Annual Inspection · Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1882137
21 August 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1664241
24 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1609022
28 January 2002
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481920
28 August 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444606
17 May 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418712
9 September 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449230
1 July 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402674
23 May 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378058
30 April 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385696
4 May 1995
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398240
11 October 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1173544
24 May 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401871
20 September 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429795
30 July 1993
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841632
21 May 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261226
2 October 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934007
10 May 1990
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232519
Accommodation/Occupational Safety
Issued 28 August 2001
Resolved
REPLACE MOLDY CEILING PANELS IN CREW'S QUARTERS.
Condition: Unknown
Due 28 September 2001
Resolved 7 September 2001
Resolution: Tiles replaced.
Electrical
Issued 28 August 2001
Resolved
REMOVE DEAD END WIRES, PROPERLY SECURE REMAINING WIRES WITH METAL TIE WRAPS, AND PROPERLY SPLICE WIRES IN ENGINE ROOM.
Condition: Unknown
Due 28 September 2001
Resolved 22 September 2001
Resolution: Wires removed and tie wraps installed.
Engineering
Issued 28 August 2001
Resolved
REPLACE MAIN ENGINE FUEL RETURN LINES WITH PIPE, SHORTEN HOSES NOT TO EXCEED 30".
Condition: Unknown
Due 28 September 2001
Resolved 22 September 2001
Resolution: Pipes lengthened with hoses less than 30".
Lifesaving
Issued 9 September 1999
Resolved
PROVIDE COAST GUARD APPROVED RESCUE BOAT PER D8 LTR 12NOV98.
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Electrical
Issued 9 September 1999
Resolved
REMOVE ALL DEAD END WIRES AND PLUGGED HOSES THROUGHOUT ENGINEROOM. PRIOR TOCOMPLETION OF DRYDOCK ON 05MAY2000.
Condition: Unknown
Due 5 May 2000
Resolved 20 September 1999
Documentation
Issued 24 May 1994
Resolved
PROVIDE ONBOARD APPROVED OPERATING MANUAL AND STABILITY LETTER.
Condition: Unknown
Due 24 May 1994
Resolved 24 May 1994
Lifesaving
Issued 21 May 1992
Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED RESCUE BOAT.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Engineering
Issued 21 May 1992
Resolved
PROVIDE A PRESSURE/TEMPERATURE RELIEF VALVE NOT MORE THAN 100 PSIG, AND 210DEGREES FAHRENHEIT FOR ONBOARD WATER HEATER.
Condition: Unknown
Due 21 May 1992
Resolved 21 May 1992
Documentation
Issued 10 May 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE COAST GUARD MARINE CENTER FOR ISSUANCEOF STABILITY LETTER.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Documentation
Issued 10 May 1990
Resolved
PROVIDE ON BOARD ROUGH COPY OF OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46CFR 109.121.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Documentation
Issued 10 May 1990
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE AND A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Documentation
Issued 10 May 1990
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990