MAURY USCG vessel records Sign in
← All vessels

CAPT. JIM RHODES

CAPT. JIM RHODES is a 1982 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1982, most recently in March 2023, along with 67 deficiencies and 2 casualty investigations between 2005 and 2006.

Records from 1982 to 2023. Most recent: inspection, 2 March 2023.

Built
1982
Last inspected
2 March 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE8003
Flag
UNITED STATES
367400330
Maury page id
psix-54370

Inspections, by type

…with no type recorded5
Years with a record 34 calendar years (1982–2023)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.6 ft × 17.0 ft × 7.7 ft
Registered tonnagegross 57 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Regulatory (Subpart C or D), Net Ton
57 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE8003MMSI 367400330 · active · compulsorily equipped · granted 3 January 2019, expires 21 March 2029
WRB5629MMSI not assigned · expired · compulsorily equipped · granted 5 August 1997, cancelled 15 December 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SUPERIOR BRAVERY Offshore Supply Vessel · MISLE 165037 · 21 April 2005 · activity 2342167

Inspection history · 46

2 March 2023 Deficiency Check · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7633600
18 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7433196
30 March 2021 Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7152122
14 April 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6931406
24 May 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6692537
8 March 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6638999
20 February 2018 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6357806
2 March 2017 Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6093959
14 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5851272
7 October 2010 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3859799
21 August 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3302265
3 July 2007 Administrative Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2981802
26 July 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2725625
28 June 2006 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2694213
21 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2342167
12 April 2005 Annual Inspection · Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2331112
1 July 2004 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2117202
31 July 2003 Hull Examination · Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1859261
8 July 2002 COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1642863
10 October 2001 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389481
19 October 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1418783
22 September 1999 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408369
23 August 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 798417
28 May 1998 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428966
25 July 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409724
10 September 1996 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355942
29 July 1996 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443727
27 November 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454275
13 September 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 867244
18 May 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392006
14 September 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1146266
18 August 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358137
10 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 837767
8 September 1992 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1265922
21 May 1992 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262395
11 September 1991 Re-Inspection · Excursion Permit
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 935105
19 April 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 929811
13 February 1991 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236328
12 September 1990 Excursion Permit
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915567
3 July 1990 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230131
3 February 1989 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032783
12 January 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322653
8 June 1987 Re-Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315401
22 January 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306038
6 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972800
15 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970559

Deficiency record · 67

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 March 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. An interconnected fire detection system has not been installed on-board the vessel. Install a interconnected fire detection system and prove proper operation to the satisfaction of the attending Marine Inspector. 46 CFR 181.450(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 9 May 2023
Resolution: Received, reviewed, and accepted documentation and photos showing install of approved interconnected fire detection system.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2023 Resolved
Marine inspector shall examine all accessible parts of the exterior and interior of the hull, watertight bulkheads, and weather deck. Cracked weld found on the base of the vertical beam within the lazarrette supporting the upper longitudinal. Grind and renew. 46 CFR 176.25-5(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Receive, reviewed, and accepted photo showing new weld completed on the vertical beam supporting the upper longitudinal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2023 Resolved
Marine inspector shall examine all accessible parts of the exterior and interior of the hull, watertight bulkheads, and weather deck. Pinholes found in outer pilothouse shell plating. Plug pinholes. 46 CFR 176.25-5(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Received, reviewed, and accepted photo showing adequate plugging of pinholes.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 March 2023 Resolved
On vessels of less than 20 meters in length, the sidelights, if necessary to meet the requirements of § 84.15, shall be fitted with matt black inboard screens. Navigation light screens found missing black background. Paint screens. 33 CFR 84.05(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Received, reviewed, and accepted photo showing correct black background behind navigation lights.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 March 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. 0ne of three fire buckets found with a hole. Replace or repair fire bucket. 46 CFR 181.610
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Received, reviewed, and accepted photo showing two new fire buckets provided for vessel with proper markings.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2023 Resolved
The certification of inspection shall, in general, be framed under glass or other transparent material and posted in a conspicuous place. Certification of Inspection, Certificate of Documentation, and Stability Letter were not properly posted. Properly post documents. 46 CFR 176.01-40(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Received, reviewed, and accepted photo showing the proper posting of all required documents onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2023 Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines. Gages for lubricating oil pressure found not operating correctly. Replace or repair. 46 CFR 182.20-5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 27 April 2023
Resolution: Received, reviewed, and accepted photos showing install and operation of new gages at operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 March 2023 Resolved
All life floats and buoyant apparatus shall be of approved type. The subparts in Subchapter Q contain the specifications for lifefloats to meet approval series 160.027. Vessel to replace lifefloat to meet the specification standards listed in 46 CFR 160.027, Subchapter Q for lifefloats to include drop down net. Vessel's passenger count reduced to 24 POB until the installation of a CG approved lifefloat that meets 46 CFR 160.027 standards. 46 CFR 180.10-1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 27 April 2023
Resolution: Received, reviewed, and accepted photos showing installation of new CG approved lifefloat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2023 Resolved
Marine inspector shall examine all accessible parts of the exterior and interior of the hull, watertight bulkheads, and weather deck. Crack identified in deck longitudinal near starboard stuffing box. Grind and renew. 46 CFR 176.25-5(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Received, reviewed, and accepted photo showing new weld where crack was ID'd in the deck longitudinal near starboard stuffing box.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 March 2023 Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. Starboard main engine found with missing lagging around engine turbos. Replace or renew. 46 CFR 182.15-20(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Received, reviewed, and accepted photo showing install of new lagging around engine turbos.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 28 March 2023 Resolved
All vessels shall be fitted with such ground tackle and hawsers as deemed necessary by the Officer in Charge, Marine Inspection. Vessel unable to provide adequate anchor onboard. Provide anchor that satisfies vessel's route and size. 46 CFR 184.10-1(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 24 April 2023
Resolution: Received, reviewed, and accepted photo showing adequate anchor provided onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022 Resolved
01 life jacket was found not to be serviceable. Reduce passenger count to 37 until life jacket is replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: 38 Lifejackets found to be in satisfactory condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2022 Resolved
Water intrusion was observed in the pilot house overhead were electrical switches are installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Resolved water intrusion in pilothouse.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2022 Resolved
Bonding wire not installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Installed bonding wire on fuel tank in lazerette.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 May 2022 Resolved
Lanyard is frayed and breaking apart. Replace lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Replaced lanyard on lifebuoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 May 2022 Resolved
Light in the lazarette missing bulb and guard. Dead end wires were found behind operator console on the bridge. Install guards on light fixture and secure dead end wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Installed guard on light and secured wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2022 Resolved
Exhaust hose was cut the length of hose. Silicone was used to rejoin the two ends. Replace hose to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Replaced and double clamped hose on exhaust piping.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022 Resolved
Placard was not available for all types of life jackets carried on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Installed placard for both types of lifejacket donning.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 May 2022 Resolved
Connection for Lube Oil gauge is leaking behind operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Secured leak behind steering console.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022 Resolved
Portable Light on the bridge is extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2022
Resolution: Replaced batteries in portable light in wheelhouse.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 March 2021 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. Engine room hatches are not fitted with latches that allow them to be secured for sea.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2021
Resolved 22 April 2021
Resolution: Installed latches on engine room hatches
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 30 March 2021 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 April 2021
Resolved 22 April 2021
Resolution: Marked emergency fuel shutoff location
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 March 2021 Resolved
Generators and motors for use in machinery spaces shall generally be designed for an ambient temperature of 50 degrees C. Observed nameplate data stated that ambient temperature rating was for 40 degrees C. Either provide updated nameplate with a 50 degree C rating, or derate generator to 80%.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2021
Resolved 22 April 2021
Resolution: New nameplate provided with 50 degree C ambient temp rating
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2021 Resolved
Acid batteries shall be located in a tray of lead or other suitable material resistant to deteriorating action by the electrolyte. Observed several holes in both battery boxes allowing for the electrolyte to spill directly to the bilge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2021
Resolved 22 April 2021
Resolution: replaced both main battery boxes and placed generator battery in plastic box.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 30 March 2021 Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3, the operator must secure each Type III device in a manner which prevents discharge of sewage. Acceptable methods of securing the device include— (1) Closing each valve leading to an overboard discharge and removing the handle; (2) Padlocking each valve leading to an overboard discharge in the closed position; or (3) Using a non-releasable wire-tie to hold each valve leading to an overboard discharge in the closed position. Observed that there was no way to ensure that overboard discharge valve would be secured in the closed position.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 April 2021
Resolved 22 April 2021
Resolution: Installed chain and lock on sewage overboard discharge valve.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 March 2021 Resolved
Doors on a cooking appliance must be provided with hinges and locking devices to prevent accidental opening in heavy seas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2021
Resolved 22 April 2021
Resolution: installed latches on refrigerator.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 30 March 2021 Resolved
At each inittial and subsequent inspection for certification of a vessel, the owner or manging operator shall be prepared to conduct tests and have the vessel ready for inspection of life saving equipment and systems. Rescue platform for recovering man overboard could not be located.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2021
Resolved 22 April 2021
Resolution: returned jacobs ladder to vessel
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 30 March 2021 Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. There are no rails on the stern deck of the vsl. Either install new rails or place a sign at the exit of the cabin stating that no passengers are permitted on deck while transiting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2021
Resolved 22 April 2021
Resolution: installed signage limiting back decks while underway
Fire Fighting › Portable Foam Applicators › General
Issued 27 February 2018 Resolved
Found ONE BI Fire extinguisher in pilot house and ONE BI in engine room. Only TWO BII in accomodation spaces. COI requires ONE BI and FOUR BII. Add additional BII and upgrade type to meet number required by COI.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 27 February 2018
Resolved 27 February 2018
Resolution: Resolved all descrepancies by procuring and stocking entire compliement of fire extinguishers required by COI.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 February 2018 Resolved
No Drug & Alcohol Program policy nor MIS reports available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 2 March 2018
Resolution: Recieved email from Buds Boat Rentals showing proof of DAPI enrollment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 February 2018 Resolved
Medicines in First Aid Kit Expired. Stock vessel with complete First Aid Kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 27 February 2018
Resolution: Purchased and stocked brand new First Aid Kit.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 16 March 2017 Resolved
Portable fire extinguisher in engine room was last serviced in FEB 2016. Provide proper inspection records from third party.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 16 March 2017
Resolution: Replaced extinguisher with one in compliance. Same type.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 March 2017 Resolved
Owner or operator must repaint fore and aft draft marks in contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 6 March 2017
Resolution: Owner re-painted draft marks.
Lifesaving › Buoyant Apparatus › Approval
Issued 2 March 2017 Resolved
Starboard life float is missing approval plaque attesting to Coast Guard compliance. Provide plaque and documentation attesting to approval prior to carrying greater than 12 passengers. Vessel is restricted to carrying 12 or less passengers until requirements have been met & approved by CG Marine Inspector. 46CFR180.200(a)(2)
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 22 March 2017
Resolution: Ordered new life float and replaced in-kind. provide documentation attesting to CG approval.
Electrical › Electric Supply System (service) › Cable
Issued 2 March 2017 Resolved
Deteriorating wiring observed on battery cable leading to generator. Repair to satisfaction of CG Marine Inspector.
Action required: 705 - Other - as specified
Due 23 March 2017
Resolved 22 March 2017
Resolution: Replaced wiring in-kind. Provided pictorial proof.
Engineering › Fuel Oil Service System › Piping
Issued 14 April 2016 Resolved
Vessel's generator has a high pressure supply fuel oil line to the #2 injector leaking. Repair to satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2016
Resolved 3 May 2016
Construction/Loadline › Structures › Deck Plating
Issued 14 April 2016 Resolved
2 holes found in overhead deck plate for lazarette space. Repair to satisfaction of CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2016
Resolved 3 May 2016
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 April 2016 Resolved
Port side aft wooden deck above main void space is water-logged. Source of water leak from above deck unidentified. Locate and repair leak(s) and replace deck as needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2016
Resolved 10 May 2016
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 April 2016 Resolved
COI not posted on vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 3 May 2016
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 14 April 2016 Resolved
Remove deep fat fryer from berthing space.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 3 May 2016
Documentation › Certificates/Documents › Stability Letter
Issued 14 April 2016 Resolved
Stability letter not posted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 10 May 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 14 April 2016 Resolved
Provide waste management plan.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 10 May 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 April 2016 Resolved
Stern, anchor and searchlights inoperable. Repair.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 14 May 2016
Resolved 3 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 April 2016 Resolved
Dead end wires found in main and passenger void compartment.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 3 May 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 April 2016 Resolved
Clean out battery boxes and protect batteries from dripping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 3 May 2016
Communications › Alarms/Indicators › Fire Alarm
Issued 14 April 2016 Resolved
Install smoke alarm in berthing area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 10 May 2016
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 April 2016 Resolved
Remove power strip found plugged in inside cabin seating area.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 3 May 2016
Documentation › Logs/Records › Logbook (official)
Issued 14 April 2016 Resolved
No EPIRB checks logged for last 3 months.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 12 May 2016
Documentation › Logs/Records › Logbook (official)
Issued 14 April 2016 Resolved
Provide weekly, monthly inspections logged for survival craft.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 12 May 2016
Documentation › Logs/Records › Logbook (official)
Issued 14 April 2016 Resolved
Provide crew list and safety orientation.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 3 May 2016
Navigation › Piloting/Steering › Marine Charts
Issued 14 April 2016 Resolved
Provide chart of sufficient scale for area of operation.
Action required: 705 - Other - as specified
Due 14 May 2016
Resolved 10 May 2016
Engineering › Bilge Water Management System › Hose
Issued 7 October 2010 Resolved
Clamps missing on hose in front of STBD engine
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Lifesaving › Lifefloat › Markings
Issued 7 October 2010 Resolved
label lifefloats and oars & secure oars to lifefloat, also connect life floats to painter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Engineering › Generator (propulsion/auxiliary-electric) › Ground Detection Equipment Circuitry
Issued 7 October 2010 Resolved
Repair ground detection on switchboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Engineering › Generator (propulsion/auxiliary-electric) › Indicator Circuitry
Issued 7 October 2010 Resolved
Indicator lights out on switchboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Construction/Loadline › Penetrations › Gasket
Issued 7 October 2010 Resolved
Gaskets need to be replaced
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 October 2010 Resolved
Remove wire & junction boxes not in use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Engineering › Generator (propulsion/auxiliary-electric) › Coil
Issued 7 October 2010 Resolved
Wrap generator exhaust pipe
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Engineering › Fuel Oil Service System › Hose
Issued 7 October 2010 Resolved
Replace clamps and grounding strap
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Engineering › Bilge Water Management System › Interface Detector
Issued 7 October 2010 Resolved
Mount bilge alarm in engine room
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Construction/Loadline › Hull › Weld
Issued 7 October 2010 Resolved
Multiple pick-ups in laz
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Engineering › Bilge Water Management System › Piping
Issued 7 October 2010 Resolved
Bilgle suction forepeak pipe missing
Action required: 705 - Other - as specified
Due 7 November 2010
Resolved 19 October 2010
Construction/Loadline › Hull › Hull Plating
Issued 21 August 2008 Resolved
Prior to carrying cargo on aft deck, remove wooden planks to allow inspection of deck by attending Coast Guard Marine Inspector. Make repairs as necessary if desired prior to inspection.
Action required: 705 - Other - as specified
Due 26 August 2008
Resolved 16 October 2008
Resolution: Deck replaced, repairs satisfactory.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 July 2007 Resolved
Prior to carrying passengers or cargo make vessel available for dry dock examination.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2007
Resolved 28 August 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 July 2004 Resolved
Remove all wire nuts under wheel house and on MSD.
Condition: Improper Installation
Due 1 July 2004
Resolved 1 July 2004
Engineering › Steering Gear System › Ram
Issued 1 July 2004 Resolved
Rudder stops fractured and steering needs adjusted to prevent reaccurance of fractures to steering stops.
Condition: Damaged By Earlier Event
Due 1 July 2004
Resolved 1 July 2004
Accommodation/Occupational Safety
Issued 18 May 1994 Resolved
REPLACE PRESSURE RELEIF VALVE WITH VALVE SET AT NO GREATER THAN 100 PSI AND200 DEGREES FAHRENHEIT ON THE HOT WATER HEATER IAW 46CFR176.25-30(b).
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994

Casualty record · 2

21 April 2005Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 2342167
6 November 2006Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 2815706
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.