PILARGAS

PILARGAS is a 2007 tank ship. The Coast Guard has recorded 13 inspections since 2021, most recently in December 2025, along with 28 deficiencies and 1 operational control.

Records from 2021 to 2025. Most recent: inspection, 27 December 2025.

Built
2007
Last inspected
27 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 December 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2021–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9441685
3E2061
1657946
Flag
PANAMA
Maury page id
psix-1657946

Documentation record

Tonnage as PSIX records it6743 - Convention (Subpart B), Gross Ton
9197 - Dead Weight, Metric Ton
13110 - Displacement, Metric Ton
2433 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SAN MARCOS Passenger (Inspected) · MISLE 51518 · 12 October 2023 · activity 7807820

Inspection history · 13

27 December 2025 PSC B · In-Service Inspection · COC-GAS Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8287430
2 January 2025 COC-GAS Annual
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8050911
16 October 2024 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8017434
24 September 2024 PSC A
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8006475
20 April 2024 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7896133
28 March 2024 Deficiency Check · PSC B · ISM Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7885391
19 December 2023 Deficiency Check · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7839054
12 October 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7807820
17 December 2022 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7608570
4 November 2022 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7590017
13 July 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7505760
22 December 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7371665
11 December 2021 PSC A · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7366382

Deficiency record · 28

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 December 2025 Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the Code to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. PSCO was made aware of several intermittent vapor leaks as detected by the Marine Chemist and crew to include the #1 cargo tank "B" pump gauge, the #1 cargo tank "B" pump shaft seal, and from an unknown source in the starboard compressor room. PSCO cannot verify that the cargo containment system and associated piping is vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 January 2026
Resolution: Received TPO report attesting to absence of toxic vapours in areas identified by marine chemist subsequent to crew tightening of associated flanges/glands. Marine Chemist certified all spaces during class surveyor attendance.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 24 September 2024 Resolved
To assist in casualty investigations, ships, when engaged on international voyages... shall be fitted with a voyage data recorder (VDR) as follows: ships, other than passenger ships, of 3000 gross tonnage and upwards constructed on or after 1 July 2002. VDR is in-operable due to these following codes: 18, 22, and 174. 74 SOLAS (2020 Cons.) V/20.1.4. Action code: 17ac.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2024
Resolution: Received satisfactory class report.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil/water interface detector
Issued 24 September 2024 Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the Administration and shall be such as will ensure that any oily mixture discharged into the sea... PSCO observed OCM flickering during operational test and reviewing history of the OWS. MARPOL (2022 Cons) Annex I/14.6. Action code: 17ac.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2024
Resolution: Crew fixed OWS to the satisfaction of RO. See attached report for information.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 24 September 2024 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part 1 so that all entries in the book appropriate to the operation are completed. Each completed operation shall be signed by the officer or officers in charge of the operations concerned and each completed page shall be signed by the master of the ship. The entries in the Oil Record Book (ORB) Part 1 for ships holding and International Oil Pollution Prevention Certificate, shall be at least in English, French, or Spanish. Where entries in an official language of the state whose flag the ship is entitled to fly are also used, this shall prevail in case of dispute or discrepancy. PSCO observed the following entries in the ORB: 16APR24, 09AUG24, and 22SEP24. The entries did not match for length, throughput, and times. After review, C/E signs all operations even though 2/E completed transfer. Also had missing entry of transfer completed after 22SEP24. Reviewed sounding log and soundings did not match operation on 22SEP24. MARPOL (2022 Cons) Annex I/17.4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2024
Resolution: RO verified that incorrect entries were corrected and that missing entries were properly logged. See survey report for more details.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 24 September 2024 Resolved
Ship staff training should include familiriazation in the operation and maintenance of the equipment. PSCO observed crew using a brush to test OWS and did not follow proper testing procedures. MARPOL (2022 Cons) Annex I/14.6, MEPC.107(49) 1.1.5. Action code: 40ac.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 September 2024
Resolution: Instructions were re-emphasized by RO representative and training was provided to all relative personnel. See attached RO survey for more details.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 September 2024 Resolved
Each fire drill shall inclide: Checking of fireman's outfit and other personal rescure equipment. PSCO ovserved 01 firefighters wearing improper headgear. PSCO also observed 01 crewmembers holding door without firefighting equipment. 74SOLAS (2020 Cons) III/19.3.5.2.3. Action code: 10c.
Action required: 10 - Deficiency Rectified
Due 25 September 2024
Resolved 25 September 2024
Resolution: Crew was given a second opportunity to complete fire drill. Deficiencies were corrected during this attempt.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 20 April 2024 Resolved
The rescue boat embarkation and launching arrangements shall be such that the rescue boat can be boarded and launched in the shortest possible time." Davit arm required 2 minutes and 56 seconds to swing from rescue boat launching station to lowering position, and swung in a bouncing manor that is unsafe for any crew on board the rescue boat. 74 SOLAS (20) III/17.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 April 2024
Resolution: Class attested to temporary repair of the davit arm accumulator.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage of rescue boats
Issued 20 April 2024 Resolved
Every inflatable liferaft shall be serviced: at intervals not exceeding 12 months2. PSCO observed wrong liferaft SN on servicing record resulting in uncertainty of liferaft servicing. 74 SOLAS (20) III/20.8.1
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2024
Resolution: class report with photos
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 20 April 2024 Resolved
Machinery spaces of category A shall be adequately ventilated so as to ensure that when machinery or boilers therein are operating at full power and adequate supply of air is maintained to the space for the safety and comfort of personnel and the operations of the machinery. Any other machinery space shall be adequately ventilated appropriate for the purpose of that machinery space. PSCO and PSCE's 4 gas alarmed while observing the Emergency Diesel Generator (EDG) exhaust ventilating back into the EDG compartment filling it with carbon dioxide. 74 SOLAS (04) II-1/35
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 May 2024
Resolution: class report with photos
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed gear adrift throughout steering gear space. 74 SOLAS (04) I/11 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2024
Resolution: class report with photos
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 20 April 2024 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unless the Administration is satisfied that such equipment is of a type which will not ignite the mixture concerned. PSCO observed 1 cracked EX lens in compressor room. SOLAS II-1/45.10.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2024
Resolution: class report with photos
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 April 2024 Resolved
Suitably marked decontamination shower and eyewash should be available on deck in convenient locations. The showers and eyewash should be operable in all ambient conditions. PSCO observed eye wash station to have insufficient water pressure. Crew was able to clean eye wash station and increase pressure and flow. Deficiency cleared. 74 SOLAS VIII/13.1 IGC Code 14.4.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 April 2024
Resolution: Crew cleaned eye wash station nozzles and demonstrated sufficient water pressure.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 March 2024 Resolved
Objective evidence discovered in an expanded ISM exam revealed the following major non-conformity; the vessel failed to fully implement the requirements of the SMS as evident by deficiencies # 1-10. An external audit is required. 74 SOLAS (2020 cons) IX/3 ISM Code Part A 9
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: A external audit was completed
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 March 2024 Resolved
In meeting these requirements, the company should ensure that: .1 inspections are held at appropriate intervals. The main diesel engine had maintenance overdue up to 5004 hours as of 29FEB2024 which includes the fuel valves, cross head bearing, crank pin bearing, and main bearing. Main diesel engine turbo had maintenance overdue by up to 5004 hours as of 29FEB2024 which includes the safety valves, exhaust valves, scavenge inspection, deflection gauging and hydraulic valve actuator. Shipboard diesel generator #1 was overdue for inspection by up to 4853 hours to include the cylinder cover and fuel valves as of 29FEB2024. 74 SOLAS (2020 cons) IX/3 ISM Code Part A 10.2.1
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: Class completed a internal inspection of #1 SSDG and is scheaduled to be overhauled.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 28 March 2024 Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. These measures should include the regular testing of stand-by arrangements and equipment or technical systems that are not in continuous use. The air compressor that provides starting air to the main diesel engine was inoperable, therefore the procedures for ensuring reliability were not being followed and spares were not available to ensure continuation of operation in the event of a failure. 74 SOLAS (2020 cons) IX/3 ISM Code Part A 10.3
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: Vessel crew repaired start air compressor.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 28 March 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Two of the oil mist detectors were covered by plastic bags and an additional one was found inoperable. 74 SOLAS (2020 cons) IX/3 ISM Code Part A 10.1
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: Crew repaired oil mist detectors
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Documentation-ISM
Issued 28 March 2024 Resolved
The company should establish and maintain procedures to control all documents and data which are relevant to the safety management system. Pre arrival checks did not include procedures for testing the standby or emergency generator. Reference SMS Form SN.02/revision 00. 74 SOLAS (2020 cons) IX/3 ISM Code Part A 11.1
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: Company updated a pre-arrival checks and sent to entire fleet.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 28 March 2024 Resolved
The company should ensure that all personnel involved in the company’s safety management system have an adequate understanding of relevant rules regulations, codes, and guidelines. Crew could not demonstrate proficiency of vessel emergency steering and emergency fire pump procedures in a timely manner. PSCO had to show crew the posted testing procedures to conduct the emergency steering gear test. 74 SOLAS (2020 cons) IX/3 ISM Code Part A 6.4
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
Resolution: Crew completed training on proper operation and PSC examiners tested knowledge and skill of systems.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 March 2024 Resolved
The machinery and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. The main diesel engine had a significant leak from the No.7 jacket water. 74 SOLAS (2004 cons) II-I/26.1
Action required: 30 - Ship detained
Resolved 7 April 2024
Resolution: Crew replaced O ring slowing leak to drip. A condition of class was issued for further repairs at later date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2024 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Special consideration shall be given to the malfunctioning of: an air compressor and receiver for starting or control purposes. Only 1 (one) of the 2 (two) compressors that provide starting air was functional. 74 SOLAS (2004 cons) II-I/26.3.9
Action required: 30 - Ship detained
Resolved 7 April 2024
Resolution: Verified proper operation of the starting air compressor.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 28 March 2024 Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted... The door for storage room “E” on the poop deck was not capable of closing. 74 SOLAS (2009 cons) II-2/9.4.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2024
Resolution: Verified proper operation of the fire door.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 March 2024 Resolved
"A" class divisions formed by bulkheads and decks which comply with the following criteria: they are insulated with approved non-combustible materials such that the average temperature of the unexposed side will not rise more than 140 degrees Celsius above the original temperature, nor will the temperature, at any point, including any joint, rise more than 180 degrees Celsius above the original temperature within the time listed below: class "A-60" 60 min. The class A boundary separating emergency escape from the engine room was found to be insufficient with insulation falling out and patched with non approved tape. 74 SOLAS (2009 cons) II-2/3.2.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2024
Resolution: Verified proper install of new insulation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 March 2024 Resolved
Whenever there is a hazardous condition either on board a vessel or caused by a vessel or its operation, the owner, agent, master, operator, or person in charge must immediately notify the nearest Coast Guard Sector Office or Group Office. The vessel failed to report the following hazardous conditions to the Coast Guard: Starting air compressor inoperable and leaking jacket water on main diesel engine. 33CFR160.216(a)
Action required: 10 - Deficiency Rectified
Resolved 7 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 March 2024 Resolved
(a) Except as provided in paragraphs (b) and (c) of this section no person may cause a vessel to enter into or get underway on the navigable waters of the United States unless no more than 12 hours before entering or getting underway, the following equipment has been tested: (3) Standby or emergency generator, for as long as necessary to show proper functioning, including steady state temperature and pressure readings. Crew did not perform an emergency generator test prior to entry. 33CFR164.25(a)(3)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 April 2024
Resolution: Company updated prearrival checks to entire fleet. Crew demonstrated proper operation of the emergency generator.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 19 December 2023 Resolved
The system should be capable of covering all areas mentioned in 11.3.1 with a uniformity distributed water-spray of at least 10 L/m2 per minute for protected surfaces and 4 L/m2 per minute for vertical surfaces. The deck water spray system did not adequately cover the port manifold, #1 tank dome, or compressor rooms. 74SOLAS(20) VII/13.1 IGC(93) 11.3.2 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: Spray nozzles were cleared, lines blown down, and tested sat in the presence of the PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 December 2023 Resolved
Remote starting of pumps supplying the water-spray system and remote operation of any normally closed valves in the system should be arranged in suitable locations outside the cargo area. The water-spray remote controls from the CCR were not working. The discharge valve had to be manually opened in the engine room. 74SOLAS(20) VII/13.1 IGC(93) 11.3.6 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: The engineering crew overhauled the remote valve and tested remote control from the CCR satisfactorily.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 December 2023 Resolved
The changing of the set pressure under the provisions of 8.2.6 should be carried out under the supervision of the master in accordance with procedures approved by administration and specified in the ship operating manual. The MARV setting for both cargo tanks is set at 6.6 Bar, the ICOF requires the MARVS reduce to 5.8 Bar when loading VCM. The crew stated that MARVs are never changed on board a vessel that only loads VCM in Corpus Christi. 74SOLAS(20) VII/13.1 IGC(93) 8.2.7 17 a/c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2023
Resolution: The master removed the 6.6 Bar auxiliary device, and proved compliance with the IGC regulations and ICOF conditions.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2023 Resolved
Electrical Installations should be as to minimize the risk of fire and explosion from flammable products. Two EX lights were found with cracked lenses. One in the STBD compressor room and one in the port compressor room. 74SOLAS(20) VII/13.1 IGC(93) 10.1.2 15 a/c
Action required: 15 - Rectify deficiencies by next port
Resolved 19 December 2023
Resolution: Crew had lights replaced with spares after paperwork was issued but before departing the vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.