HOLOKAI

HOLOKAI is a 2000 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 2001, most recently in June 2026, along with 46 deficiencies and 3 casualty investigations between 2012 and 2023.

Records from 2001 to 2026. Most recent: inspection, 9 June 2026.

Built
2000
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA3300
Flag
UNITED STATES
366796860
Maury page id
psix-16692

Inspections, by type

…with no type recorded4
Years with a record 23 calendar years (2001–2026)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.0 ft × 14.0 ft × 5.8 ft
Registered tonnagegross 19 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderKVICHAK MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 2000
Hull materialAluminum
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationTwin Hull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Gross Ton
15 - Simplified, Net Ton
6 - Dead Weight, Ton
20 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA3300MMSI 366796860 · active · compulsorily equipped · granted 12 January 2021, expires 10 January 2031
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ATLANTIS IX Passenger (Inspected) · MISLE 363954 · 2 July 2004 · activity 2123860

Inspection history · 43

9 June 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8396253
17 October 2025 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8249123
19 February 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8081443
21 March 2024 Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7871902
19 December 2023 Drydock Exam · In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7828722
9 August 2023 Damage Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770010
9 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7776875
22 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7639934
17 March 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7412624
15 February 2022 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7397013
29 January 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7132112
20 March 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6929815
5 March 2020 Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6920875
25 February 2020 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6915691
12 March 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6652257
19 February 2019 Internal Structural Exam · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6630679
9 May 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6410155
19 April 2018 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6395289
16 February 2018 Administrative Inspection · Examination of Repairs · Internal Structural Exam · In-Service Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6356354
21 September 2017 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 6272136
1 February 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6087835
16 February 2016 In-Service Inspection · Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5807603
13 January 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5800077
12 March 2014 COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4814434
7 February 2012 Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4240183
2 February 2010 In-Service Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3672537
30 March 2009 DAPI Audit · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3444316
23 April 2008 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3190590
5 February 2008 Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3142477
6 June 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2953556
27 February 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2878801
21 March 2006 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2608193
21 February 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2589285
17 February 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2294514
6 December 2004 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2254594
2 July 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2123860
26 February 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2013880
4 March 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1752708
27 February 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1749856
17 December 2002 Deficiency Check · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1710523
7 March 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1490957
25 April 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1062036
21 February 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373470

Deficiency record · 46

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 February 2025 Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. The 6 red hand flares and 6 orange hand flares were expired. Replace to the satisfaction of attending marine inspector. 46 CFR 180.68(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2025
Resolution: 12 new red flares are onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 February 2025 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard as practicable and made watertight. The cable penetrations in port and starboard watertight bulkheads are not watertight. Make cable penetrations tight and prove tightness to the satisfaction of the attending Marine Inspector. Once resolved the vessel’s route is restricted to 3nm from shore until the life floats and EPIRB deficiencies below are resolved. 46 CFR 171.114(a)(1-2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2025
Resolution: MI atteneded vessel to clear deficiency.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 February 2025 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up to date. Vessel could not produce valid EPIRB registration. Provide valid EPIRB registration to the satisfaction of the attending Marine Inspector. The vessel’s route is restricted to 3nm from shore until all the life floats deficiencies are resolved. 47 CFR 80.1061(f)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 February 2025
Resolution: Agent provided valid EPIRB Registration.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2025 Resolved
The painter line on a life float must be stowed in such a way that it runs out freely. The installed painter line was packed in a way that did not allow it to run out freely from the cage. Prove painter line is stowed so it runs out freely to the satisfaction of the attending Marine Inspector. The vessel’s route is restricted to 3nm from shore until all the life floats deficiencies are resolved. 46 CFR 180.175(f)(3)(iv)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 17 April 2025
Resolution: Operator repacked painter line properly.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2025 Resolved
The light of a life float must be a floating water light approved under approval series 161.010 or other standard specified by the Commandant. The batteries of both life float water lights were expired. Replace with approved batteries and prove proper operation of the water lights to the satisfaction of the attending Marine Inspector. The vessel’s route is restricted to 3nm from shore until all the life floats deficiencies are resolved. 46 CFR 180.175(f)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 17 April 2025
Resolution: Life float batteries replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2025 Resolved
Each life float must be fitted with two paddles. One paddle in the aft life float was cracked. Replace to the satisfaction of the attending Marine Inspector. The vessel’s route is restricted to 3nm from shore until all the life floats deficiencies are resolved. 46 CFR 180.175(d)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2025
Resolved 17 April 2025
Resolution: Paddle replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2025 Resolved
Each paddle must be marked with the name of the vessel Aft life float paddle name not legible. Mark with vessel name to the satisfaction of the attending Marine Inspector. The vessel’s route is restricted to 3nm from shore until all the life floats deficiencies are resolved. 46 CFR 185.604(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 17 April 2025
Resolution: Vessel name legible.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2025 Resolved
Each buoyant apparatus must have type II retroreflective material meeting subpart 164.108 of this chapter on each side and end. The retroreflective material on the forward life float was degraded. Replace in-kind to the satisfaction of the attending Marine Inspector. The vessel’s route is restricted to 3nm from shore until all the life floats deficiencies are resolved. 46 CFR 160.010-4(p)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 17 April 2025
Resolution: Retro replaced satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2025 Resolved
The life float must be fitted with a light attached to the body of the float with a lanyard at least 18 feet in length. The lanyard for the light was under 18 feet in length. Make lanyard for the light 18 feet in length to the satisfaction of the attending Marine Inspector. The vessel’s route is restricted to 3nm from shore until all the life floats deficiencies are resolved. 46 CFR 180.175(f)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 17 April 2025
Resolution: Lanyard measured to 18 feet, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2025 Resolved
All fuel tanks must be electrically bonded to a common ground. Port side fuel tank was not bonded to a common ground. Re-attach fuel tank bonding wire to the satisfaction of the attending Marine Inspector. 46 CFR 182.440 (b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 17 April 2025
Resolution: Bonding reattached satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2025 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. There are three (3) blade type fuses installed under the main helm console. Replace in-kind with an approved UL cartridge fuse of the same amperage rating to the satisfaction of the attending Marine Inspector. 46 CFR 183.380 (l)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 17 April 2025
Resolution: Approved UL cartridge installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 March 2024 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system in compliance with 181.410: A space containing propulsion machinery. Fireboy for port engine room inoperable. Provide a certified technician service report & demonstrate all shutdowns, alarms, and overrides to the attending USCG marine inspector. 46 CFR 181.400(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: Witnessed successful operation of installed system and servicing report.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 March 2024 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Make port side compartments watertight where Roxtec blocks are missing where cable penetrations are located. 46 CFR 179.320(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: Roxtec blocks added at cable penetrations.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2024 Resolved
The OCMI may require the vessel to get underway. Get underway in presence of marine inspector to conduct drills and complete COI. 46 CFR 176.404(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2024
Resolution: Satisfactory drills conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 March 2024 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation for dewatering the port side compartments using the installed bilge manifold. 46 CFR 182.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2024
Resolution: Demonstrated operation of dewatering on the port side using installed bilge manifold.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2024 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Replace expired aspirin inside first aid kit. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2024
Resolution: Aspirin replaced.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 March 2024 Resolved
A vessel must be fitted with a FCC type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operation station if: The vessel is self-propelled, the vessel has an oceans, coastwise, limited coastwise, or great lakes route and the vessel carries more than 49 passengers. Vessel does not have a radar and is self propelled, has a limited coastwise route and carries 70 passengers. Vessel limited to 49 passengers until radar is installed. 46 CFR 184.404(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2024
Resolution: Radar installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 21 March 2024 Resolved
At each initial and sebsequent inspection for certification of a vessel, the owner of managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: inspection of all railing and bulwarks and their attachment to the hull structure. Finish installing port side upper rub railing. 46 CFR 176.802(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2024
Resolution: Rub rail installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 March 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Many life jackets were not marked properly with appropriate retroreflective material. Provide appropriate markings to the satisfaction of the attending marine inspector. 46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Retroreflective material added to life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2024 Resolved
Vessel is required to have one 20" or 24" ring lifebuoy fitted with 60' lifeline and floating water light attached with a corrosion resistant clip to allow quick disconnect. Ring lifebouy did not have 60' lifeline attached. Provide proper arrangement of ring lifebuoy, to include the lifeline. 46 CFR 180.70(c)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: 60' line added to ring lifebuoy.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 March 2024 Resolved
In addition to meeting 180.130 each life float and buoyant apparatus must be stowed as required under this section, certified to meet 160.073 in subchapter Q of this chapter, or other standard specified by the Commandant. Properly repair torn life float grab line where attached. 46 CFR 180.137(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 May 2024
Resolution: Life float repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Observed flexible hose discharge side of fire pump/bilge pump torn/wasted in port engine room. Renew hose in port engine room. 46 CFR 182.100
Action required: 10 - Deficiency Rectified
Resolved 22 February 2023
Resolution: New hose installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 February 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Numerous life jackets had retro material that had lost its reflectiveness. Provide new retroreflective material to life jackets. 46 CFR 185.604
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 21 March 2023
Resolution: Retro tape provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 February 2023 Resolved
Each vessel must be equipment with at least two operable portable battery lights. One light must be located at the operating station and the other at the access to the propulsion machinery space. Vessel did not have any portable lights. Provide 3 portable lights, one at the operating station and one at each engine room. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 23 February 2023
Resolution: 03 lights provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2023 Resolved
Gauges to indicate engine RPM, cooling water temp, and lube oil pressure must be provided for engine. Stbd side oil pressure not operational. Provide working gauge. 46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 16 March 2023
Resolution: New gauge installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 March 2022 Resolved
Spanner wrench must be provided where a 1.5 inch diameter fire hose is required. Vessel missing spanner wrench. Provide spanner wrench. 46 CFR 181.310(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 15 April 2022
Resolution: Spanner wrench provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 March 2022 Resolved
Fire hose with nozzle must be attached to hydrant at all times. Hose was attached to hydrant but did not make a good connection and was leaking. Secure leak at hydrant/hose connection. 46 CFR 181.320
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2022
Resolved 15 April 2022
Resolution: Leak secured.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 26 February 2020 Resolved
The release pin for the starboard engine compartment’s emergency ventilation closure was seized, prohibiting it from being removed. Replace / repair pin to allow for the closure of emergency ventilation to the space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2020
Resolved 20 March 2020
Resolution: Received notification and proof that the release pin for the starboard engine compartment’s emergency ventilation closure was replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 February 2020 Resolved
Pitting was found in the port sewage compartment’s deck plating in the vicinity of the compartment’s lowest and aft most part, directly below the high water alarm. Correct at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2020
Resolution: Upon further investigation of affected area after removal of tank in dry dock, only minor pitting discovered not warranting repair at this time. Location will be monitored. Special note added.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 19 April 2018 Resolved
11115-Conduct satisfactory man overboard drill. Inadequate means to recover person in water.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 9 May 2018
Resolution: Adequate means provided.
Engineering › Fuel Oil Service System › Piping
Issued 19 April 2018 Resolved
13101-Inspection of all fuel system. High pressure fuel lines clamps are loose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 9 May 2018
Resolution: Fuel lines secured.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 19 April 2018 Resolved
07115-Ventilation closures general condition. Closures do not close properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2018
Resolved 9 May 2018
Resolution: Closures close properly.
Lifesaving › Lifefloat › Serviceable
Issued 1 February 2017 Resolved
22 person lifefloat not in serviceable condition.
Due 31 March 2017
Resolved 14 August 2017
Resolution: Contacted [name withheld] stated he remebered clearing def. Contacted vesel rep [name withheld] who provided photographs sent to [name withheld] 24March17 of new lifefloat.
Engineering › Bilge Water Management System › Pump
Issued 1 February 2017 Resolved
Stbd bilge pump not operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2017
Resolution: Vessel rebuilt bilge pump.
Stability › Watertight Integrity › General
Issued 2 February 2010 Resolved
Complete underway sea trial with CG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2010
Resolution: Completed satisfactory underway sea trial.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 2 February 2010 Resolved
Make shafts available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Resolution: Shafts visually inspected with no deficiencies to the satisfaction of attending marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 2 February 2010 Resolved
Damage to weld located on starboard quarter. Submit plan to repair weld as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Resolution: Repairs found to the satisfaction of attending marine inspector.
Construction/Loadline › Hull › Side Shell
Issued 2 February 2010 Resolved
Damage in the form of a large chip found along starboard chine weld. Submit plan to repair as original.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Resolution: Repairs found to the satisfaction of attending marine inspector.
Engineering › Bilge Water Management System › Valve
Issued 1 April 2009 Resolved
REPLACE CHECK VALVES WITHIN ENGINE ROOM WITH POSITIVE ACTION VALVE FOR SUBMERSIBLE BILGE PUMP SYSTEMS BOTH PORT AND STARBOARD.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 20 April 2009
Engineering › Bilge Water Management System › Piping
Issued 5 February 2008 Resolved
Make repairs to bilge/fire pump suction pipe. Both ends are excessively corroded through the barbed fitting.
Action required: 705 - Other - as specified
Resolved 8 February 2008
Resolution: Cut back pipe to remove barbed fittings and expose good material. New hose and clamps installed.
Engineering › Bilge Water Management System › Piping
Issued 5 February 2008 Resolved
Make repairs to the aluminum piping leading to the port bilge manifold. Fittings are excessively corroded.
Action required: 705 - Other - as specified
Resolved 8 February 2008
Resolution: Cut back pipe to remove barbed fittings and expose good material. New hose and clamps installed.
Construction/Loadline › Hull › Stringer
Issued 21 February 2006 Resolved
Provide repair proposal and conduct repairs to breaks around the two exhaust brackets (engine room stringers) on the port side.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2006
Resolved 3 March 2006
Resolution: Conducted repairs
Engineering › Bilge Water Management System › Valve
Issued 21 February 2006 Resolved
Repair or replace leaking check valve in the 12 volt bilge sytem located in the engine space on teh port side to stop leaking.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 3 March 2006
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 21 February 2006 Resolved
Provide covers for the bus panels on the port and starboard side in the engine spaces that are forward of the engines.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2006
Resolved 3 March 2006
Communications › Radio Communications
Issued 27 February 2003 Resolved
Replace hydrostatic release unit for EPIRB. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Due 10 March 2003
Resolved 4 March 2003
Construction/Loadline › Structures
Issued 17 December 2002 Resolved
Make available rudders, shafts and propellers, IAW 46 CFR 176.610, prior to the completion of drydock. LEGACY COMPONENT DESC: Rudder, Shafts, and Propellers
Action required: 705 - Other - as specified
Resolved 19 December 2002

Casualty record · 3

2 November 2012Routine · role: Involved in a Marine Casualty · activity 4479053
12 March 2019Routine · role: Suspected Pollution Source · activity 6652257
9 August 2023Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7776875
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.