Records from 1991 to 1999. Most recent: inspection, 30 April 1999.
Inspection history · 17
30 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 68693
21 December 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 809371
16 January 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1121008
31 December 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398830
4 April 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1091845
24 March 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1107289
28 February 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1469151
22 October 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460914
11 January 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412901
8 January 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 879586
23 February 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385378
13 January 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373964
11 February 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366787
29 April 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 958476
8 April 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 150217
13 January 1992
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 959847
22 August 1991
Hull Examination · Initial Certification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 933898
Deck/Cargo
Issued 31 December 1997
Resolved
Repair cracked welds IWA of combing & main deck attachments on vertical hopper braces:stbd side#1,5,7,8,9,15,16,17,18,19,23,24,25 Port side#10,11,12,13,15,20,21,22,19. Braces numbered from front to back.
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Deck/Cargo
Issued 31 December 1997
Resolved
Repair crack IWA of corner hopper combing atport fwd and aft corners.
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Deck/Cargo
Issued 31 December 1997
Resolved
Repair hole in hopper plate port side between vertical braces #26 & 27 above long.
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Deck/Cargo
Issued 31 December 1997
Resolved
Repair cracked weld in hopper longitudinal on stbdside 4ft from stern.
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Deck/Cargo
Issued 31 December 1997
Resolved
Repair crack in combing in way of weld between stbd vertical braces #11 & 12.
Condition: Unknown
Due 31 December 1997
Resolved 31 December 1997
Deck/Cargo
Issued 28 February 1997
Resolved
REPAINT BRAVO FLAG SYMBOL RED.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Lifesaving
Issued 28 February 1997
Resolved
REMOVE LADDER INSIDE HOPPER SPACE.
Condition: Unknown
Due 28 February 1997
Resolved 28 February 1997
Construction/Loadline
Issued 13 January 1992
Resolved
Remove all doublers from bow and stern deck (total of 6) and properly insert.
Condition: Unknown
Due 13 January 1992
Resolved 13 January 1992