Records from 2021 to 2026. Most recent: inspection, 16 April 2026.
Documentation record
Registered dimensions (L × B × D)59.7 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 70 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderORANGE SHIP BUILDING COMPANY INC · ORANGE, TX, UNITED STATES · built 2007
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 12 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Simplified, Net Ton
70 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
16 April 2026
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8353759
5 November 2025
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8257334
17 October 2024
Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8020764
24 September 2024
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8008882
19 March 2024
Damage Survey · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7882067
11 March 2024
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7886504
8 November 2023
Annual Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7824267
9 February 2023
USCG Audit · Security Plan Review - ASP · Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7634818
4 November 2022
Deficiency Check · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7586927
19 September 2022
Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7562048
5 April 2022
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7425470
20 October 2021
Initial Certification · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7337165
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 March 2024
Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. The hull of the vessel was damaged from an earlier grounding which consisted of multiple sharp insets at the fore peak compartment, starboard fuel oil tank, and exterior bottom plating of the machinery space. Provide repair proposal and conduct repairs to satisfaction of attending marine inspector.
46 CFR 137.300 (b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 March 2024
Resolution: Satisfactory insert repairs were placed over 03 separate areas with sharp insets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 November 2022
Resolved
Owners or operators must implement an Approved Security Program in its entirety to be in Maritime Security compliance. The following non-conformities were identified during the inspection:
1. There was no certified Vessel Security Officer (VSO).
2. The crew was not familiar with the Security Plan.
3. There was a physical copy of the plan that was not secured as required by the plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2022
Resolved 23 November 2022
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 November 2022
Resolved
All fire protection equipment and systems, to include machinery shutdowns, must be tested every 12 months. The following non-conformities were identified during the inspection:
1. The fire-detection system power was secured, batteries unwired, and servicing is out of date.
2. The machinery space fixed suppression system servicing is out of date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2022
Resolved 23 November 2022
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 November 2022
Resolved
The vessel must have the means to provide notification at the operating station when a high bilge level alarm is activated. The high level alarms only activate a visual and audible signal on the engine room alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2022
Resolved 23 November 2022
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 4 November 2022
Resolved
The vessels engine room must be fitted with a supplemental flashing red light that operates during the General Alarm. The red light does not operate when the General Alarm is activated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2022
Resolved 23 November 2022
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 November 2022
Resolved
Each lifejacket must have a light and whistle secured by a cord. All lifejackets did not have whistles.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2022
Resolved 23 November 2022
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 November 2022
Resolved
The vessel must be equipped with the navigation lights, shapes, and sound signals necessary for the vessels operation. The Stern Tow light does not work and the vessels sound signal does not meet the decibel level.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2022
Resolved 23 November 2022
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 20 October 2021
Resolved
Each operating station must have alarms for main engine low lubrication oil pressure, main engine high cooling water temp, ,uxiliary generator engine low lubricating oil pressure, auxiliary generator engine high cooling water temperature, low hydraulic steering fluid levels, and low fuel day tank level. Alarms must be visible and audible from the bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 5 April 2022
Resolution: Tested all Alarms, All sat.