Records from 1994 to 2025. Most recent: inspection, 20 June 2025.
Inspection history · 26
20 June 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8163134
6 August 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7975428
20 June 2023
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7718982
9 December 2022
Examination of Repairs
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7606811
13 October 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7576630
11 January 2022
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7380007
23 July 2021
Initial Certification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7265652
9 November 2017
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6307496
27 September 2017
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6276557
14 September 2017
Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6279395
24 August 2017
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6250179
31 May 2012
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4344741
25 April 2012
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4288880
3 November 2010
Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3887993
9 March 2010
Deficiency Check · Industry Initiated Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3693850
25 August 2008
MTSA Verification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3311415
25 May 2008
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3218884
24 May 2004
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2076959
11 May 2004
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2074280
6 March 2001
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 290222
7 July 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 160322
8 July 1998
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 417872
26 September 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 408444
16 June 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 406611
4 May 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 112719
18 March 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 80253
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 June 2025
Resolved
Fire system must be inspected annually. Provide inspection report for fire panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2025
Resolved 22 August 2025
Resolution: Operator completed fire panel inspection record.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 June 2025
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Provide adequate supplies.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2025
Resolved 22 August 2025
Resolution: Provided new first aid kit.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 13 October 2022
Resolved
Each remote valve control must be marked in clearly legible letters, at least 25 millimeters (1 inch) high, indicating the purpose of the valve and the way to operate it. Label fuel shut off valve controls.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 13 October 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 October 2022
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. Mount a 40-B near the flammable cabinet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 13 October 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 October 2022
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Items in first aid kit located at the operating station was expired. Remove expired equipment and replace with new items.
Action required: 10 - Deficiency Rectified
Due 27 October 2022
Resolved 13 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Bare radio equipment wires located at the operating station, connect/ cap bare wires.
Action required: 10 - Deficiency Rectified
Due 27 October 2022
Resolved 13 October 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Opening within breaker panel at the operating station by way of missing breaker/ blank. Cover opening within breaker panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2022
Resolved 13 October 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2021
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel's fuel connect crossover piping had multiple fuel leaks. Fuel was leaking into the bilge. Ensure crossover pipe does not leak to the satisfaction of attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2021
Resolved 24 July 2021
Resolution: Fuel cross connect piping was lightly gouged and rewelded.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 23 July 2021
Resolved
Vessel is required to have a means to secure ventilation to the engine room in the event of fire. Vessel does not have a means to secure ventilation. Provide a means to secure ventilation to the satisfaction of the attending MI.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2021
Resolved 24 July 2021
Resolution: Visit operator supplied temporary means of securing ventilation until permanent repairs could be installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2021
Resolved
Vessel is required to have USCG approved alcohol strips available for the entire crew. Vessel does not have alcohol test strips onboard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2021
Resolved 24 July 2021
Resolution: Alcohol strips purchased by Port Engineer.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 23 July 2021
Resolved
Closure devices must be provided for deckhouse or hull penetrations. Vessel's gasket material for watertight hatches was insufficient. Renew gaskets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 13 October 2022
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 23 July 2021
Resolved
Each exhaust pipe from an internal combustible engine which is within reach of personnel must be insulated or otherwise guarded to prevent burns. Vessel's exhaust lagging had bare spots where crew could reach or hit with head. Place lagging over exposed areas of piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 11 January 2022
Resolution: Lagging installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2021
Resolved
The waterlight must be attached by the lanyard with a corrosion-resistant clip to allow the waterlight to be quickly disconnected. Attached applicable clips.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 3 December 2021
Resolution: Operator installed clips
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 July 2021
Resolved
Vessel is to have Emergency Broadcast Placard at the operating station. Post Emergency Placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 6 December 2021
Resolution: Vessel purchased and installed placard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 July 2021
Resolved
Vessel is to frequently inspect towing gear and ensure towing gear is serviceable. Inspect / log towing gear inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 11 January 2022
Resolution: Towing log / sheet onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2021
Resolved
Vessel is to have name and hailing port affixed. Vessel does not have name and hailing port affixed. Affix name and hailing port to the satisfaction to attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2021
Resolved 11 January 2022
Resolution: Hailing port and name permanently affixed to stern.
Electrical
Issued 6 March 2001
Resolved
Missing blank in breaker panel.
Condition: Unknown
Due 6 April 2001
Resolved 18 May 2001
Lifesaving
Issued 6 March 2001
Resolved
PFD was missing from the bridge, captain replaced it prior to Coast GUard personnel departing the vessel.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Electrical
Issued 6 March 2001
Resolved
light cover was missing or improperly installed.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Electrical
Issued 6 March 2001
Resolved
Lens cover on halogen docking light was missing.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Fire Fighting
Issued 6 March 2001
Resolved
Portable fire extinguisher was improperly mounted. Coast Guard instructed mariner to lay it down and secure it until mounting brackets could be procured.
Condition: Unknown
Due 6 April 2001
Resolved 21 May 2001
Navigation
Issued 16 June 1997
Resolved
VESSEL DIDN'T HAVE OFFICIAL NUMBER PERMANENTLY MARKED ON HULL OR STRUCTURALMEMBER.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Navigation
Issued 16 June 1997
Resolved
VESSEL WAS MISSING IT'S STERN AND MASTHEAD LIGHTS.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Documentation
Issued 16 June 1997
Resolved
VESSEL DID NOT HAVE MARPOL PLACARD POSTED.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997