DIRK TAYLOR is a 1979 towing vessel. The Coast Guard has recorded 17 inspections since 1997, most recently in May 2026, along with 16 deficiencies, 1 operational control and 2 casualty investigations between 2007 and 2026.
Records from 1997 to 2026. Most recent: inspection, 31 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)56.5 ft × 26.1 ft × 8.4 ft
Registered tonnagegross 117 / net 80
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRY BOAT BUILDERS · MORGAN CITY LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRACINE, OH
Trade endorsementsCoastwise, Bowaters
DocumentationValid · issued 2 April 2026 · expires 30 April 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it117 - Regulatory (Subpart C or D), Gross Ton 80 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 1980 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 August 2022Resolved
A vessel on a rivers route must carry 3 day and 3 night visual distress signals (or 3 approved under approval series 160.036 or 160.136 which are acceptable as both day and night signals). The required day and night visual distress signals were expired. Supply the vessel with adequate number of valid visual distress signals.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 August 2022
Resolution: Flares purchased for placement onboard the vessel
Master's medical certificate expired. Provide proof of medical certificate form submission to NMC or that the process has been started (i.e. medical appointment for physical scheduled).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 August 2022
Resolution: Medical certificate renewal process started with the physical being scheduled.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 June 2021Resolved
Oily rags stored in large plastic garbage cans. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no opening in the sides or bottoms. Remove plastic garbage cans from the engine room and replace with metal one(s).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 28 June 2021
Resolution: Plastic garbage cans removed and replaced with metal ones
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 May 2019Resolved
The vessel's station bill must identify the duties and duty stations of each person onboard during an emergency. The posted emergency duties listed on the vessel's station bill did not list sufficient details of the duties of each member.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2019
Resolution: Revised and put in place
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2019Resolved
Electrical systems and equipment must minimize fire and shock hazards. Found stray wires (dead ends) on a radio installation and underneath the helm at the operating station on the bridge. Properly secure wires to minimize hazards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2019
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2019Resolved
Each lifebuoy on a towing vessel must be marked in block capital letters with the name of the vessel. The name of the vessel was peeling off of the starboard lifebuoy. Correct by a more permanent means.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2019
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2019Resolved
All lifejacket containers must be marked in block capital letters and numbers with the minimum quantity. The lifejacket storage on the bridge must be properly marked.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2019
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 May 2019Resolved
The sternlight must be visible from a distance of 2 miles. Due to the installed location of the sternlight, the light became blackened by the smoke from the engine exhaust. Ensure visibility is adequately maintained.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 8 May 2019
Resolution: Corrected while onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 8 May 2019Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Repair the starboard ladder on the upper deck which had loose railing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 October 2019
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Holds and tanks safety
Issued 8 May 2019Resolved
Pressure vessel spring-loaded relief valves are to be set to prevent pressure from exceeding the MAWP by more than 10 percent (MAWP is established by the manufacturer). Verify setting of relief valves on Port & Starboard pressure vessels and provide proof of MAWP/valve settings.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2019
Resolution: Settings verified (MAWP/Valve settings are 200 psi. Relief valves are 150 psi).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2019Resolved
Each distribution panel or switchboard must have non-conductive mats or grating on the deck in front of each panel. No non-conductive mats or grating installed. Install non-conductive mats or grating.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2019
Resolution: Mats installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 8 May 2019Resolved
Marine sanitation device (MSD) was missing a placard posted with the operating instructions, safety precautions, and warnings pertinent to the device.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 October 2019
Resolution: Placard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2019Resolved
The battery box located in the engine space showed signs of corrosion on the terminals. Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2019
Resolution: Cleaned.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 May 2019Resolved
Semi-portable 160-B fire extinguisher fitted with wheels must have the frame or support permanently attached to a steel bulkhead or deck to prevent it from rolling.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 May 2019
Resolution: Permanently attached with welds.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 May 2019Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Ensure both main engines, including the turbos, are lagged to provide adequate insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 November 2019
Resolution: Insulated covers installed.
Operations/Management › Cargo Transfer/Lightering
Issued 3 September 2002Resolved
Vesssel transfer procedures were missing the piping diagram, declaration of inspections, and a current person in charge list. LEGACY COMPONENT DESC: Vessel Transfer Procedures on Hand
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2002
Resolved 29 January 2004
Resolution: CORRECTED BY O/O''S
23 June 2007Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 3 dead · activity 2970939
31 May 2026Routine · role: Transiting Vicinity of Primary Subject · activity 8405484
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.