Records from 1986 to 2023. Most recent: inspection, 17 May 2023.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 62
17 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7694176
25 August 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7545849
23 August 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7294024
28 May 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6962331
30 April 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6946039
29 May 2019
Annual Inspection · MARPOL Annex VI Survey · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6697766
15 May 2018
Internal Structural Exam · Periodic Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6414967
7 August 2017
Administrative Inspection · Annual Inspection · Deficiency Check · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6232825
26 October 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6030208
17 May 2016
MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5879771
22 April 2015
MARPOL Annex VI Survey · Deficiency Check · Internal Structural Exam · MARPOL Annex I Examination · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5108717
24 June 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4897212
11 July 2013
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4649350
8 July 2013
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4642769
25 September 2012
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4449107
13 June 2011
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4043478
14 June 2010
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3763819
15 May 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3479235
5 June 2008
Examination of Repairs · Drydock Exam · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3227916
22 April 2008
Drydock Extension · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3185412
16 May 2007
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2932388
26 July 2006
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2707970
27 June 2006
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2692784
8 April 2005
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2329141
28 April 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1782178
11 March 2002
Re-Inspection · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1602408
9 February 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058737
7 March 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 815713
2 March 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471006
29 March 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1369109
15 March 1999
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1420092
10 March 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1420091
14 March 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388483
23 January 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1461851
19 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1110857
28 January 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470127
17 January 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385656
2 December 1994
Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1374193
9 November 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 80734
9 November 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 98766
10 May 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 859200
12 July 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 843806
4 March 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 842232
18 February 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1144640
12 May 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1254731
13 August 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1253361
25 July 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1254104
5 March 1991
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 934869
15 February 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 917445
26 July 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1240015
5 July 1990
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1212586
5 June 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1241096
21 August 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1202008
29 June 1989
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1208806
10 August 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1037930
1 June 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1194036
22 February 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1332393
20 July 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329140
20 May 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1023972
6 June 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1306243
4 June 1986
Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 993655
29 May 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1301402
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 August 2021
Resolved
Life Buoys shall be marked with Type I retroflective tape; Retro was found wasted. 46 CFR 199.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 26 August 2021
Resolution: Vessel rep sent photos of newly placed retro-reflective tape on ring buoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 August 2021
Resolved
All fuel piping shall be protected from mechancial injury; fuel hose for winch engines were wasted.
46CFR56.50-70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2021
Resolved 26 August 2021
Resolution: New fuel hoses were installed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 August 2017
Resolved
COD not onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 7 August 2017
Resolution: Original found at office and put onboard prior to completion of inspection.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 7 August 2017
Resolved
Transfer procedures not available. 33 CFR 155.740
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 7 August 2017
Resolved 7 August 2017
Resolution: Procedures found in SOPEP. Section copied and placed near transfer area, before completion of inspection.
Electrical › Electric Supply System (service) › Cable
Issued 7 August 2017
Resolved
Wire on air compressor found with insulation missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 August 2017
Resolved 30 August 2017
Resolution: Electrical power supply cable to air compressor replaced
Deck/Cargo › Mooring/Anchoring › Winch
Issued 7 August 2017
Resolved
Identified fuel hose on STBD Winch Engine severely deteriorated and weathered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 30 August 2017
Resolution: Fuel hose on STBD Winch Engine replaced
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 22 April 2015
Resolved
Replace supply and return flexible nonmetallic hoses on both generators with hoses that meet SAE J1942 standards for fuel applications. (46 CFR 56.60-25(b)).
Action required: 705 - Other - as specified
Due 27 June 2015
Resolved 12 June 2015
Resolution: Vessel has replaced all fuel hoses with correct CG approved hoses.
Engineering › Fuel Oil Service System › Piping
Issued 22 April 2015
Resolved
Prior to operating generator, replace fuel cap for aux generator.
Action required: 705 - Other - as specified
Resolved 27 April 2015
Resolution: New fuel cap for auxiliary generator has been satisfactorily installed.
Engineering › Compressed Air System (start air) › Valve
Issued 22 April 2015
Resolved
Prior to operating air receive, replace safety relief valve on crane engine room air compressor. (46 CFR 54.15-10g)
Action required: 705 - Other - as specified
Resolved 27 April 2015
Resolution: MI witnessed satisfactory operational test of crane room air receiver safety relief valve (relieved at 150 psi).
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 27 June 2006
Resolved
Make available for inspection the crane.
Due 27 July 2006
Resolved 26 July 2006
Electrical › Electric Supply System (service)
Issued 28 April 2003
Resolved
Properly secure all wiring in crane house. LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Due 5 May 2003
Resolved 29 April 2003
Electrical › Electric Supply System (service)
Issued 28 April 2003
Resolved
Remove portable heater and extension cord from crane operator house.
Condition: Placed in Improper Service
Due 5 May 2003
Resolved 29 April 2003
Electrical
Issued 28 April 2003
Resolved
Relocate space heater in Accom. space away from wiring bundle.
Condition: Placed in Improper Service
Due 5 May 2003
Resolved 29 April 2003
Electrical › Lighting (service)
Issued 28 April 2003
Resolved
Install light cover in crane operator house. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 5 May 2003
Resolved 29 April 2003
Fire Fighting › Semiportable CO2 Fire Extinguishers
Issued 28 April 2003
Resolved
Properly secure B-V fire extinguisher LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 5 May 2003
Resolved 29 April 2003
Electrical
Issued 2 March 2000
Resolved
Replace generator seal.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Electrical
Issued 2 March 2000
Resolved
Make repairs to generator for exhaust leak.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Electrical
Issued 2 March 2000
Resolved
Repair/hardwire conduit on aft crane room blkhd.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Electrical
Issued 2 March 2000
Resolved
Replace power available light on generator.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Engineering
Issued 2 March 2000
Resolved
Remove excess oil in crane room.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Electrical
Issued 2 March 2000
Resolved
Repair overhead lighting fixture in workshop and provide wire supports to all electrical wiring.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Electrical
Issued 2 March 2000
Resolved
Remove or mount microwave in workshop.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Lifesaving
Issued 2 March 2000
Resolved
Provide suitable guards on anchor cable IWO walkways on port and starboard side aft of crane house/main deck.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Navigation
Issued 2 March 2000
Resolved
Paint navigation light brackets flat black.
Condition: Unknown
Due 2 April 2000
Resolved 7 March 2000
Documentation
Issued 15 March 1999
Resolved
Provide following original documents on board vessel to satisfaction of attending marine inspector: COD, COFR, IOPP, ILLC _x001C_ _x001C_ (ABS survey completed; awaiting issuance of provisional loadline cert.)
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Documentation
Issued 15 March 1999
Resolved
Provide current certificate of crane test results to satisfaction of attending marine inspector.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Construction/Loadline
Issued 14 March 1998
Resolved
MAKE DIESEL FUEL TANKS(2) READY FOR INSPECTION, GAS FREE, AND PROVIDE MARINE CHEMIST CERTIFICATE FOR SAFE ENTRY BY USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1998
Resolved 1 April 1998
Engineering
Issued 10 May 1994
Resolved
PROVE THE PROPER OPERATION OF PRESSURE RELIEF VALVES ON ALL AIR RECEIVERS PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 10 July 1994
Resolved 28 July 1994
Lifesaving
Issued 10 May 1994
Resolved
PROVIDE AN ADULT LIFE PRESERVER TYPE I TO BRING THE TOTAL LIFE PRESERVERS ON BOARD TO SEVEN(7), PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 10 July 1994
Resolved 28 July 1994
Fire Fighting
Issued 10 May 1994
Resolved
PROVIDE TWO(2) FIRE AXES ON BOARD PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 10 July 1994
Resolved 28 July 1994
Fire Fighting
Issued 12 July 1993
Resolved
PROVIDE PROOF OF HYDROSTATIC TEST FOR ALL EXTRA B-II FIRE EXTINGUISHERS ON BOARD OR REMOVE FROM BARGE PRIOR TO OPERATION.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Fire Fighting
Issued 12 July 1993
Resolved
RAISE FIXED CO2 EXTINGUISHER CYLINDER BOTTLE IN ELECTRICAL ROOM OFF METAL DECK AT LEAST TWO INCHES.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Fire Fighting
Issued 12 July 1993
Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER WITH CURRENT HYDROSTATIC TEST PRIOR TO OPERATION OF BARGE.
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Fire Fighting
Issued 12 July 1993
Resolved
PROVIDE PROOF OF HYDROSTATIC TEST OF SEMI-PORTABLE FLEX LOOP HOSE PRIOR TO OPERATION OF BARGE._x001C_
Condition: Unknown
Due 12 July 1993
Resolved 12 July 1993
Construction/Loadline
Issued 12 May 1992
Resolved
REBUILD ELECTRICAL ROOM DURING NEXT DRYDOCK PERIOD.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Lifesaving
Issued 15 February 1991
Resolved
Remove 10 man life raft to approved servicing facility for annual servicing.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991
Documentation
Issued 5 June 1990
Resolved
PROVIDE ON BOARD VESSEL A VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Fire Fighting
Issued 5 June 1990
Resolved
SERVICE FIXED FIREFIGHTING SYSTEM OR REMOVE.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Navigation
Issued 5 June 1990
Resolved
PROVIDE A CURRENT COPY OF THE NAVIGATION RULES OF THE ROAD AND ENSURE VESSEL COMPLIES WITH LIGHTS/DAY SHAPES, IAW COMDINST M16672.2A.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Accommodation/Occupational Safety
Issued 5 June 1990
Resolved
PROVIDE MANUFACTURERS NAME PLATE DATA SPECIFICATIONS FOR THE PRESSURE VESSEL MOUNTED WITH THE WINCH ENGINE AND CONDUCT INTERNAL INSPECTION OR RE-PLACE PRESSURE VESSEL WITH AN ASME TANK THAN IS RATED FOR THE SERVICE INTENDED. THE RELIEF VALVE SHALL BE SIZED FOR THE SERVICE INTENDED, BUT NOT
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Documentation
Issued 5 June 1990
Resolved
PROVIDE A REVISED COPY OF THE OIL TRANSFER PROCEDURE TO THE LOCAL OCMI FOR REVIEW.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Engineering
Issued 5 June 1990
Resolved
PROVIDE METALLIC PIPE HANGERS FOR THE FUEL OIL PIPING TO THE DIESEL ENGINESIN THE CRANE.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Engineering
Issued 5 June 1990
Resolved
REPLACE FUEL OIL RETURN LINE IN WAY OF THE FUEL OIL TANK ON THE CRANE.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Lifesaving
Issued 5 June 1990
Resolved
PROVIDE A 10-MAN LIFE RAFT TO BE PERMANENTLY INSTALLED WITH A CRADLE. THE RAFT SHALL BE SERVICED ANNUALLY AND HAVE AN ANNUALLY SERVICED HYDROSTATIC RELEASE DEVICE THAT WILL ALLOW THE RAFT TO FLOAT FREE.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Electrical
Issued 5 June 1990
Resolved
PROVIDE BATTERY INSTALLATIONS WITH A NON-CORROSIVE LINER IAW 46 CFR 111.15-5(H) AND COVERS OVER EACH BATTERY TO PREVENT OBJECTS FROM FALLING ONTHEM.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Electrical
Issued 5 June 1990
Resolved
DEAD END IN A JUNCTION BOX OR REMOVE THE UNUSED WIRE CABLE THAT EXTEND DOWNFROM THE BASE OF THE CRANE.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Electrical
Issued 5 June 1990
Resolved
REMOVE ALL PORTABLE SO/SJO CABLE THROUGHOUT THE VESSEL AND REPLACE WITH WIRE IAW 46 CFR 111.60. ALL WIRING DETAILS SHALL BE CG APPROVDED PRIOR TO ANY ALTERATIONS.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Lifesaving
Issued 5 June 1990
Resolved
PROVIDE 2 30-INCH RING BUOYS, EACH EQUIPPED WITH A WATERLIGHT AND A 60-FOOTLENGTH OF LINE, LABELED WITH THE VESSEL'S NAME.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Fire Fighting
Issued 5 June 1990
Resolved
PROVIDE 2 FIRE AXES LABELED WITH THE VESSEL'S NAME.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Electrical
Issued 5 June 1990
Resolved
REMOVE ALL TEMPORARY LIGHTING FIXTURES AND EXTENSION CORDS THROUGHOUT THE VESSEL AND PERMANENT INSTALL LIGHTING FIXTURES IAW 46 CFR 111.60.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Electrical
Issued 5 June 1990
Resolved
INSTALL NON-CONDUCTING HANDRAILS AND NON-CONDUCTING MATTING IN WAY OF THE 220V SWIVEL BUS CONNECTER LOCATED IN CENTER OF STOREROOM.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Lifesaving
Issued 5 June 1990
Resolved
PROVIDE 7 ADULT SIZE LIFE JACKETS TO BE INSPECTED AND STAMPED BY A CG MARINE INSPECTOR. THE STOWAGE SHALL BE MARKED AS TO THE NUMBER OF JACKETS STOWED AND EACH LIFE JACKET SHALL HAVE/BE: TYPE I, EQUIPPED WITH 200 SQ CMOF RETRO-REFLECTIVE TAPE, AND EQUIPPED WITH LIGHTS.
Condition: Unknown
Due 5 June 1990
Resolved 5 June 1990
Documentation
Issued 29 June 1989
Resolved
PROVIDE A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY ON BOARD PRIOR TO DEPARTURE IN OCEANSIDE, CA.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Documentation
Issued 29 June 1989
Resolved
PROVIDE ORIGINAL CERTIFICATE OF INSPECTION ON BOARD PRIOR TO DEPARTURE IN OCEANSIDE, CA.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Electrical
Issued 1 June 1988
Resolved
REMOVE OR RECONNECT UNUSED WIRES TO FWD GENERATOR.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Electrical
Issued 1 June 1988
Resolved
PROVIDE GLOBES AND GUARDS FOR ALL LIGHTS IN MACHINERY SPACES.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Fire Fighting
Issued 1 June 1988
Resolved
SERVICE 100 LB CO2 HOSE REEL FIRE EXTINGUISHER.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Navigation
Issued 1 June 1988
Resolved
PROVIDE PROPER MOORING LIGHTS.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Documentation
Issued 1 June 1988
Resolved
PROVIDE NEW MARINE DOCUMENT STICKER.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988
Navigation
Issued 1 June 1988
Resolved
TEST RELIEF VALVE AND HYDRO TEST AIR RECEIVER.
Condition: Unknown
Due 1 June 1988
Resolved 1 June 1988