MAURY USCG vessel records
← All vessels

HLS CITRINE

HLS CITRINE is a 2022 tank ship. The Coast Guard has recorded 6 inspections since 2023, most recently in April 2026, along with 2 deficiencies and 1 operational control.

Records from 2023 to 2026. Most recent: inspection, 3 April 2026.

Built
2022
Last inspected
3 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9938585
1766113
Flag
LIBERIA
Maury page id
psix-1766113

Documentation record

Tonnage as PSIX records it55383 - Dead Weight, Metric Ton
73892 - Displacement, Metric Ton
48805 - Convention (Subpart B), Gross Ton
21240 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STOLT LOYALTY Tank Ship · MISLE 51684 · 21 July 2024 · activity 7986030H DOUGLAS M Towing Vessel · MISLE 1375242 · 21 July 2024 · activity 7986030EDEN K Towing Vessel · MISLE 1788181 · 21 July 2024 · activity 7986030

Inspection history · 6

3 April 2026 PSC B · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8341397
4 April 2025 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8097589
21 July 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7963049
21 July 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7986030
2 May 2024 PSC B · Administrative Inspection · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7903528
9 March 2023 PSC A · COC-GAS Renew · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7648294

Deficiency record · 2

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 May 2024 Resolved
The equipment shall be capable of producing inert gas with an oxygen content no greater than 5% by volume, subject to the special requirments of Chapter 17. PSCO observed vessel's Inert Gas Generator (IGG) in inoperable. Upon operation by the ship's crew the IGG would experience verious failures and immediately shutdown. The crew was unable to demonstrate operation for a period of 2 hours.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2024
Resolved 3 May 2024
Resolution: Received Class Report attesting to appropriate repairs and training of the IGG system.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 May 2024 Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. However, hold-back arrangements fixed with remote release devices of the fail-safe type may be utilized. PSCO obersved B-15 door to Officer's mess, crew's mess, and A-deck conference room required to be self-closing per vessel's approved Fire Control Plan fitted with hold-back hooks. Additionally, PSCO observed A-0 self-closing fire door to the galley was unable to close via installed self-closing mechanism.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 May 2024
Resolved 2 May 2024
Resolution: Vessel removed unauthorized hold-back devices and adjusted self-closing door to galley.

Ownership record