Records from 1997 to 2025. Most recent: inspection, 24 July 2025.
Documentation record
Registered dimensions (L × B × D)55.8 ft × 24.1 ft × 9.2 ft
Registered tonnagegross 129 / net 87
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLOUIS G ORTIS BOAT CO INC · KROTZ SPRINGS, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portEVANSVILLE, IN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 July 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it129 - Regulatory (Subpart C or D), Gross Ton
87 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 29
24 July 2025
Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8194351
15 July 2022
Initial Certification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7485717
16 May 2022
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7451859
23 March 2022
TPO Audit
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7412989
22 December 2021
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7371497
13 July 2021
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7255494
30 June 2019
Deficiency Check · Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6732229
17 November 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5766665
4 May 2015
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5117796
15 February 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4801166
24 January 2014
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4790104
14 January 2011
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3934131
26 May 2010
Deficiency Check · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3755636
10 April 2010
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3715805
9 February 2010
Industry Initiated Exam
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3684013
14 September 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3330766
19 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3241542
3 June 2008
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3228773
20 October 2006
Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2804585
24 August 2005
MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2478424
2 June 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2086037
14 April 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2044041
4 December 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 209989
4 December 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 769139
11 April 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 659150
4 April 2001
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 21152
29 December 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 769164
16 December 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 195892
30 July 1997
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 406600
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 25 July 2025
Resolved
All accessible interior spaces to ensure that they are adequately ventilated and drained, and maintained and operate as intended. Pilot house AC not properly installed allowing for accumulation of water inside pilot house and down to 2nd deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2025
Resolution: Received TPO report clearing def
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2025
Resolved
ITV must be maintained and operated to minimize fire hazards. No flammable/ combustible liquids may be stowed in any accommodation, control, or service area. Oil stored on 1st deck crew area.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2025
Resolution: TPO provided report of def correction.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 24 July 2025
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Mold found 2nd deck shower room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2025
Resolution: TPO report provided documenting removal of mold in called out areas. Report attached.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 24 July 2025
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Only head on VSL not operational. Missing burn pan for incinerator toilet.
Action required: 10 - Deficiency Rectified
Resolved 24 July 2025
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 24 July 2025
Resolved
All accessible interior spaces to ensure that they are adequately ventilated and drained, maintained and operate as intended. Incinerator toilet not properly vented.
Action required: 10 - Deficiency Rectified
Resolved 24 July 2025
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 July 2025
Resolved
ITV must be maintained and operated to minimize fire
hazards. No more than 19 liters (five gallons) of
flammable liquids may be stowed in any machinery space.
The flammable liquids must be in containers of 3.8
liters (one gallon) or less. Each portable container of
flammable or combustible liquid used for portable
auxiliary equipment must be stowed in a paint locker or
an open location designated by the master.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2025
Resolution: TPO provided evidence to clear def.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 24 July 2025
Resolved
VSL required to complete external survey by TPO and
notify local OCMI for attendance as deemed necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2025
Resolution: Received TPO report cleasring def
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 24 July 2025
Resolved
Management audit required to include notification of
local OCMI for attendance as deemed necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2025
Resolution: Received TPO report clearing def
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 30 June 2019
Resolved
Starboard flanking rudder cylinder failed during pre-check resulting in a spill of hydraulic oil into the Ohio River. Replace starboard flanking rudder cylinder. As the port and starboard flanking rudders are linked, the vessel will be allowed to continue to operate using only the port flanking rudder cylinder until the starboard flanking rudder cylinder is replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2019
Resolved 8 July 2019
Resolution: TPO provided report to clear deficiency.