Inspection history · 48
15 August 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8215291
19 March 2025
Drydock Exam · MARPOL Annex VI Survey · COI Inspection · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8096186
26 September 2024
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8009734
5 June 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7927697
18 May 2023
Periodic Inspection · MARPOL Annex VI Survey · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694098
4 April 2023
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7662922
18 April 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7433282
24 May 2021
MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7206511
16 February 2021
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7141373
16 February 2021
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7141387
9 November 2020
Administrative Inspection · MARPOL Annex I Examination · COI Inspection · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7085865
16 April 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6942458
27 January 2020
MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6897093
16 November 2018
Administrative Inspection · Deficiency Check · Internal Structural Exam · MTSA Verification · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6581739
16 January 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6338499
17 October 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6026682
28 December 2015
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5783095
11 December 2015
COI Inspection · Internal Structural Exam · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5781915
17 November 2014
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5023709
6 August 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4946809
15 April 2014
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4838418
11 December 2013
Periodic Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4766652
28 December 2012
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4509622
31 January 2012
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4239538
30 December 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3921434
2 December 2010
MARPOL Annex I Examination · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3903054
15 March 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3910073
8 January 2009
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3389847
27 February 2008
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3153924
6 April 2007
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2903048
31 January 2006
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2576648
14 November 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2534291
1 November 2005
Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 2526535
30 October 2005
Permit to Proceed · Damage Survey
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2527610
28 October 2005
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2528655
22 September 2005
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2582727
25 May 2005
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2368324
27 April 2005
MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2344125
3 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2017221
31 December 2003
Security Plan Review - VSP
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2005384
18 November 2003
Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2002024
1 April 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1766404
28 March 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1764668
7 March 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1754014
6 March 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1901910
1 August 2002
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1655472
23 November 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1723467
12 December 2000
Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1373272
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 September 2024
Resolved
While not required onboard, the forward lifebuoy was missing a plug/needs replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2024
Resolved 8 October 2024
Resolution: Received photo, verifying correction
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 September 2024
Resolved
Sternlight did not light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2024
Resolved 8 October 2024
Resolution: Received photo showing correction; battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021
Resolved
Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel. 02 lifebuoys on port and starboard stern of barge had markings that were illegible, SOLAS tape was damaged and grab line were damaged.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 June 2021
Resolved 26 May 2021
Resolution: Received photos; ring buoys were replaced. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 16 November 2018
Resolved
02110 / 46 CFR 72.01-15(a) / 16c - Approximately 8 inch crack on side frame 7, side long 5 in #1 port tank. Must be repaired in compliance with ABS structural standards. Crop and renew frame to good steel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2018
Resolved 19 November 2018
Resolution: MIs conducted visual inspection of repairs. Steel cropped to good steel and replaced structural members in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 November 2018
Resolved
13199 / 46 CFR 56.60-25(a) / 50c - Plastic piping, not of an approved material, currently being used in ballast water piping system. Replace with approved piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2018
Resolved 5 February 2019
Resolution: Due date extended per OCMI. Pipe replaced in kind back to steel, pipe receipt attached. Pipe inspected and confirmed by ABS surveyor.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 16 November 2018
Resolved
02134 / 33 CFR 151.2025(a) / 33 CFR 151.2015(d)(3) / 10c - Vessel performed ballast water operations in multiple COTP zones without using an approved ballast water management method or exemption. Company will follow 33 CFR 151.2015(d)(3) in future.
Action required: 10 - Deficiency Rectified
Due 16 November 2018
Resolved 16 November 2018
Resolution: Operator has been made aware of ballast weater regulations and has confirmed verbally to adhere to ballast water regulations.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 7 January 2009
Resolved
Cargo #1 port side set-on areas on side shell plating with max. depth of less than 3” were found on (1) frame 4 to 7 between longitudinal 3 and 4 (2) frame 23 to 24 between longitudinal 5 and 7. #1 cargo Starboard side (3) frame 27-1/2 to 28 on side longitudinal No. 4 slightly dented. (4) frame 33 t0 33 ½ on side longitudinal No. 4 the web plate of frame No.33 in way indent slightly buckled.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 February 2009
Resolved 21 January 2009