Records from 2016 to 2025. Most recent: inspection, 30 October 2025.
Inspection history · 22
30 October 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8261056
28 May 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8145753
13 April 2024
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897203
11 December 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7837311
25 July 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7752007
8 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7527773
14 December 2021
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7367869
4 August 2021
Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7285731
27 January 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7131492
27 July 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7017593
20 July 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7011219
14 January 2020
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6896818
4 November 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849421
4 November 2019
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849487
10 September 2019
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6808130
16 May 2019
COI Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6690225
30 November 2018
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6589992
10 April 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6385254
24 October 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6293785
24 May 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6154512
24 May 2016
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5885200
29 April 2016
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5865670
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 28 May 2025
Resolved
Separation of machinery and fuel tank spaces from accommodation spaces. Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. MI observed open penetration in engine room aft bulkhead, stbd side, leading to accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 15 July 2025
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 April 2024
Resolved
"Each life ring buoy on a vessel must: Be approved in accordance with 160.050 in subchapter Q of this chapter..." All three life buoys on board had grab lines that were severely deteriorated and broke when a small amount of force was applied. Replace all 3 life ring buoys with approved replacements prior to passengers.
46 CFR 180.70 (b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Recieved photographic evidence attesting to the replacement of all three life rings onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 April 2024
Resolved
"Except when individual pumps are provided for separate spaces, individual bilge suction lines bust be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line..." Provide proof of operation of bilge manifold with check valve and strainer. Passenger count reduced to <49 until completed.
46 CFR 182.510 (c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 May 2024
Resolution: Received video evidence attesting to the operation of the bilge manifold.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 July 2023
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry— (1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and (2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel was only equipped with 6 orange signals. Vessel is limited to short 30min runs iaw 46 CFR 180.68(d) until equipped required distress signals.
Action required: 705 - Other - as specified
Resolved 28 July 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 July 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First-Aid Kit on board vessel had expired items. Vessel has 7 days to rectify deficiency.
46 CFR 184.710
Action required: 705 - Other - as specified
Resolved 28 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 July 2023
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguisher located in the "bar closet" is missing the bracket & must be secured.
46 CFR 181.500
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 July 2023
Resolved
First-aid and cardiopulmonary resuscitation (CPR) course certificates. Master did not provide proof of training.
46 CFR 11.201(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2022
Resolved
Vsl has a flexible nonmetallic hose in their piping system that did not meet SAE J-1942.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2022
Resolved 22 August 2022
Resolution: operator sent photos of installed properly rated flex piping for bilge system.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 4 August 2021
Resolved
Controls and valves for operation of fixed gas fire extinguishing system must be: A device must be provided to automatically shut down engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Found Vessel Generators not connected to automatic shutdown switch.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 August 2021
Resolved 21 October 2021
Resolution: Connected automatic shutdown to generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021
Resolved
All unfired pressure vessels must be installed to the requirements of sub chapter F (Marine Engineering) of this chapter. Pressure vessels shall be designed, constructed, and inspected in accordance with section VIII of the ASME Boiler and Pressure Vessel Code. Vessel Air Compressor was not ASME approved.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 17 August 2021
Resolved 11 August 2021
Resolution: Removed unauthorized compressor. Will use hand held signaling device.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 August 2021
Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing devise operable from both sides of the door and indicator lights at the operating station showing whether the door is open or closed. Indicating light was not operable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 August 2021
Resolved 7 September 2021
Resolution: Installed working indicator lamp on the bridge for the engineroom door.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 4 November 2019
Resolved
Make permenant repairs to crack in aft bulkhead in Lazerette, broken railing on rescue platform, and hole in port side side shell on rescue platform.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2019
Resolved 27 May 2020
Resolution: Repairs made to the satisfaction of the attending Marine Inspector.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 September 2019
Resolved
Vessel equipped with three overnight passenger accommodation spaces. All three overnight passenger accommodation spaces are missing smoke detectors. Install proper smoke detectors in these spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 September 2019
Resolution: Smoke detectors installed in all three overnight accommodation spaces.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 October 2018
Resolved
Prove proper operation of lube oil pressure gages for the MDEs.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2020
Resolution: Received satisfactory video attesting to proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 October 2018
Resolved
Prove proper operation of steering system prior to departure from SEC SENE zone.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 November 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2018
Resolved
Vessel is overdue for its annual COI inspection. Conduct annual/new to zone inspection prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2020
Resolution: Cleared due to age.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 19 October 2018
Resolved
Submit weight change calculations to the USCG Marine Safety Center and obtain lightship change determination to address weight changes on the vessel for stability prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
Resolution: Received correspondence from MSC not requiring a new stability test. See docs
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2018
Resolved
Properly mark the name and hailing port of the vessel as listed on the Certificate of Documenation prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2020
Resolution: Received satisfactory picture attesting to proper repair.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2018
Resolved
Make MDE's and SSDG's available for inspection and testing. Conduct sea trials to the satisfaction of the attending USCG Marine Inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2018
Fire Fighting › Means of Escape › Emergency Lighting
Issued 24 May 2017
Resolved
Repair/replace emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 1 June 2017
Stability › Watertight Integrity › Weathertight Enclosure
Issued 24 May 2017
Resolved
Adjust engine room watertight door to close properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 1 June 2017
Fire Fighting › Fire Pumps › Pressure
Issued 24 May 2017
Resolved
Replace/renew fire gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 1 June 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 May 2017
Resolved
Affix reflective tape on ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 1 June 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2017
Resolved
Replace floating water light with approved battery.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 1 June 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 May 2017
Resolved
Mark life jacket stowage compartments/locations
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 1 June 2017
Construction/Loadline › Structures › Door
Issued 24 May 2016
Resolved
Watertight door to engine room must be labled on both sides with letters at least 1 inch high, "WATERTIGHT DOOR - KEEP CLOSED"
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 8 June 2016
Resolution: Doors have been labeled.
Construction/Loadline › Structures › Door
Issued 24 May 2016
Resolved
At operating station, provide indicator lights showing if watertight door to engine room is open or closed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 8 June 2016
Resolution: Light is now operational.
Construction/Loadline › Penetrations › Gasket
Issued 24 May 2016
Resolved
Replace gasket on 02 forward hatches.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 8 June 2016
Resolution: Gaskets have been replaced.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 24 May 2016
Resolved
Replace hose on port side engine for bilge pump.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 8 June 2016
Resolution: Hose has been replaced.