MAURY USCG vessel records Sign in
← All vessels

BOSS LADY NYC

BOSS LADY NYC is a 1983 passenger vessel (inspected). The Coast Guard has recorded 102 inspections since 1985, most recently in March 2026, along with 382 deficiencies, 3 operational controls and 6 casualty investigations between 2011 and 2023.

Records from 1985 to 2026. Most recent: inspection, 20 March 2026.

Built
1983
Last inspected
20 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD3673
217332
Flag
UNITED STATES
366715730
Maury page id
psix-217332

Inspections, by type

…with no type recorded15
Years with a record 38 calendar years (1985–2026)
The 102 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)90.0 ft × 32.0 ft × 3.8 ft
Registered tonnagegross 91 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ. HUBERT BONNER · MILLBROOK, AL, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ7357MMSI 366715730 · active · compulsorily equipped · granted 8 September 2017, expires 8 September 2027
WDD3894MMSI 367137720 · expired · compulsorily equipped · granted 31 August 2006, cancelled 5 November 2016
WDD3673MMSI 366715730 · expired · voluntarily equipped · granted 16 August 2006, cancelled 22 October 2016
WCW5185MMSI 366717450 · expired · compulsorily equipped · granted 2 May 1996, cancelled 8 July 2006
WCW4422MMSI 366715730 · expired · compulsorily equipped · granted 17 April 1996, cancelled 17 June 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JULIETTE Passenger (Inspected) · MISLE 179215 · 4 November 2019 · activity 6849421JUSTINE Passenger (Uninspected) · MISLE 299707 · 4 November 2019 · activity 6849421HORNBLOWER HYBRID Passenger (Inspected) · MISLE 435796 · 4 July 2012 · activity 4368418

Inspection history · 102

20 March 2026 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8327267
25 August 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8217380
29 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7991750
25 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7901148
30 August 2023 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780894
31 May 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704908
6 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7809831
2 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7464784
2 May 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7442382
19 November 2021 COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7348969
4 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215677
4 February 2020 In-Service Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6903082
4 November 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849421
4 November 2019 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849428
9 September 2019 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6807206
22 August 2019 DAPI Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6792457
14 August 2019 Damage Survey · In-Service Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6783254
2 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6573193
21 October 2018 Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6565338
4 September 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6531542
20 August 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6518143
5 April 2018 Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373004
2 March 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6364673
10 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6335636
5 September 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260225
31 May 2016 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5892275
18 February 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs · Inclining Experiment
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5819771
4 July 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4368418
4 July 2012 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4368515
29 June 2012 MTSA Verification · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4360698
6 June 2012 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4335999
8 May 2012 MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4305198
15 August 2011 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4115990
8 February 2011 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3961422
17 September 2010 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3851232
24 March 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3702057
3 February 2010 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3715522
17 September 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3326854
22 August 2008 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3305865
9 July 2008 Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3263221
24 March 2008 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3170173
27 June 2007 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2976281
22 May 2007 MTSA Verification · Deficiency Check · COI Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2938897
11 October 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2798544
15 August 2006 Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2750027
6 April 2006 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2618048
24 August 2005 Annual Inspection · MTSA Verification · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2473580
24 June 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2401822
3 June 2005 MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2377781
21 June 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2105458
4 February 2004 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2056196
15 May 2003 MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1793963
22 May 2002 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1619258
19 March 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1494651
21 May 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1417295
11 July 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051321
8 June 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406757
24 April 2000 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817004
29 November 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 811324
4 August 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 774935
26 May 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1459509
4 June 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1129179
15 April 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123202
14 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1100690
1 January 1997 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 124348
4 June 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192301
11 May 1996 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 123087
27 April 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421079
6 July 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 880331
6 June 1995 MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186680
3 March 1995 COI Inspection · Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1434226
4 March 1994 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1456147
6 December 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161595
2 December 1993 Deficiency Check · Drydock Extension
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 833573
30 October 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 98378
12 July 1993 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 843912
8 July 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 827941
22 June 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 845796
28 May 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 837591
27 May 1993 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 835206
20 April 1993 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1435362
4 March 1993 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1458067
28 April 1992 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1267591
28 April 1992 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1267912
4 June 1991 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 915330
1 May 1991 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 913352
21 February 1991 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 914116
18 October 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1215304
4 June 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1228115
1 May 1990 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 899800
26 February 1990 Drydock Extension
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1216355
15 November 1989 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1231484
29 June 1989 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 895432
3 May 1989 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1036280
9 August 1988 Deficiency Check · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1036168
6 June 1988 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 887273
4 May 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1348081
17 December 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1010081
2 November 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1019374
7 May 1987 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1016167
4 March 1986 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 988348
5 March 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1291910

Deficiency record · 382

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 August 2024 Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation….” Marine Inspector observed foam blocks established by the current stability letter to be not properly installed. Outfit vessel with foam block arrangement in accordance with the vessel’s current stability letter. 46 CFR 170.120
Action required: 705 - Other - as specified
Due 5 September 2024
Resolved 11 October 2024
Resolution: All blocks in place
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2024 Resolved
(a) “All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.” Marine Inspector identified a bolt at the air induction for the forward generator that was sticking out unable to be tightened due to stripped threads. 46 CFR 183.05 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Bolt replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024 Resolved
“Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat….” Marine Inspector identified battery installation not properly secured under the bridge console. 46 CFR 183.05-20 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Battery covered and strapped down
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 August 2024 Resolved
“A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.” Marine Inspector identified expired first aid kits onboard. Outfit vessel with first aid kits that are not expired. 46 CFR 121.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: purchased new 1st aid kit
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024 Resolved
“Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit.” Marine Inspector identified twist on type connectors (wire nuts) all around vessel including, but not limited to under the pilot house and behind the DJ booth on the uppermost deck. 46 CFR 120.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Electrical connections of approved type
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2024 Resolved
“Installation of diesel engine exhaust pipe shall be in accordance with § 182.15-20...Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gastight throughout its length and shall be properly supported by noncombustible hangers or blocks.” Marine Inspector identified exhaust leak by the starboard exhaust stack on the 1st deck. Determine source of leak and provide repair plan. 46 CFR 182.20-20 OLD T; 46 CFR 182.15-20 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Exhaust leak fixed with new steel schedule 40 pipe
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 29 August 2024 Resolved
“Air-cooled propulsion and auxiliary engines installed below deck as permitted by § 182.20-10 shall be fitted with air intake ducts or piping from the weather deck. The ducts or piping shall be so arranged and supported to be capable of safely sustaining stresses induced by weight and engine vibration and to minimize transfer of vibration to the supporting structure…” Marine Inspector Identified natural ventilation gooseneck by the starboard exhaust stack to be not connected. Outfit vessel with connection to the existing gooseneck. 46 CFR 182.20-45 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: USCG MI observed goosenecks fastened
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 29 August 2024 Resolved
"(b) The minimum number of mariners holding a license or MMC officer endorsement as mate required to be carried on... every inspected, seagoing, passenger vessel must not be less than the following,...(4) All vessels of less than 100 GRT—one mate (except vessels on voyages not exceeding 12 hours in duration may, if the OCMI determines it to be safe, be operated without mates)." "...The recommended experience for the SENIOR DECKHAND is:1. 30 days experience on board the vessel. 2. 30 hours at the helm under supervision of a master or mate... thevessel's master should designate the SENIORDECKHAND in writing and a copy of this designation should be retained on board the vessel." To operate without req'd mate within SEC NY, OCMI requires full compliance with NVIC 1-91. USCG MI observed no designation letter onboard or logs of req'd training for the crew identified as senior deckhands. 46 CFR 15.810; NVIC 1-91
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: Senior Dkhands designated in writing
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2024 Resolved
"The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable." USCG MI observed several trash bins constructed of plastic, a petroleum product. Replace bins with suitable incombustible material such as metal to mitigate fire hazards. 46 CFR 177.10-5 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: Metal trash cans onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 August 2024 Resolved
"(b) Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection." Mount fire extinguisher on the bridge. 46 CFR 181.30-10 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: Extinguisher mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2024 Resolved
"(b) Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided..." Engine cooling water temperature gauge not operational on the stbd generator. 46 CFR 182.20-5(b) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Gage replaced and functions
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2024 Resolved
"Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed..." The reduction gear's oil gauge is not suitably mounted to a bracket. 46 CFR 182.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Gage mounted
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 19 February 2020 Resolved
Grind out and re-weld the underside of the insert in the male head under the toilet. The top of the weld was not inspected and will require inspection prior to clearing. If the top side of the weld is in similar shape as the underside. The insert should be ground out and re-welded on both sides to the satisfaction of the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The insert was properly welded.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 February 2020 Resolved
Make full repairs as discussed to the crack discovered in the bow rub rail. A new piece of U-channel shall be fitted and welded in place. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The crack was caused by an inpact at the bow. It was re-welded and stopped. The POC plans on re-fitting the area during the next DD period.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 19 February 2020 Resolved
Grind down and fill small hole in the rub rail decking by the bow. The area should be cleaned and inspected by the attending marine inspector prior to any paint in the area. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The hole was properly filled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 February 2020 Resolved
Crop out and replace 5 brackets and decking as identified along the Port side rub rail. Once the brackets are fitted the area shall be made available to the attending marine inspector prior to fitting the deck plating. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The rub rail was fully repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 February 2020 Resolved
Gauge area identified along the centerline just aft of the centerline keel cooler to determine steel thickness. Report finding to the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The inset was gauged and determined to have less than 5% wastage in the area. No action required.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 February 2020 Resolved
Remove interior bulkhead covering and crop and renew steel on the STBD transom where a 16" long hole was discovered along the deck plating. The area shall be cropped to good steel as discussed and fit-up made available for inspection to the attending marine inspector prior to final welding. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new steel plate was fitted.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 February 2020 Resolved
The hole discovered in the STBD rudder post shall be cleaned-out to bare metal and filled. Once filled the area shall be made available to the attending marine inspector prior to painting. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new steel plate was fitted.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 February 2020 Resolved
The old sewage discharge hole on the STBD side shall be cropped and renewed with an approx. 18"xl8" insert. The interior bulkhead coverings shall be removed and a fitup shall be proven to the attending marine inspector prior to final welding. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new steel was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the 1st and 2nd longitudinal above the chine on the Port side shall be cropped and renewed where marked or to good metal. The longitudinals shall be made available to inspect the final welds. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: New longitunidnals were fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 February 2020 Resolved
In the Laz, 05 gussets were missing and shall be replaced along the port side of the forward bulkhead. Once welded, the final welds shall be made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: New gussets were installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, along the portside overhead, two longitudinals near the forward bulkhead were discovered to be cropped out and never replaced. The longitudinals shall be re-welded in place and final welds made available for the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: New members were fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the longitudinal just aft of the sewage tank port-side edge shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitnidinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the STBD #5 longitudinal (from centerline) shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitudinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, The STBD #6 (from centerline) (tall structure member) shall be cropped where marked or to good metal. Once the area is cropped, a fit-up shall made available for the attending marine inspector prior to final welds. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The frame insert was completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the STBD #7 longitudinal (from centerline) shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitudinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the STBD #7 vertical frame (from the centerline) on the forward bulkhead shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new frame was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the #8 longitudinal (from centerline) shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitudinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2020 Resolved
Vessel shall be safe from electrical shock of personnel. On 2/5/2020, a USCG Marine Inspector received a shock while touching the hull of the M/V QUEEN OF HEARTS. Determine the cause of the electrical shock and effect necessary repairs to satisfaction of attending Marine Inspector. 46 CFR "Old T" 183.01-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: All electrical panels and boards were inspected, cleaned, and several conductors were re-affixed to the proper terminals. The cause of the shock was not identified but is believed to be corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
All conductors shall be of the stranded type. Replace or remove any solid core wiring found. Any replacement wires must comply with 46 CFR 120.240. -46 CFR "Old T" 183.05-45(b) -46 CFR 120.115(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: Solid core was removed.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
Wiring joints and splices shall be mechanically secure. Any splices found that are not made with a mechanical connection shall be redone or removed. New splices need to comply with 46 CFR 120.340. -46 CFR "Old T" 183.01-5 -46 CFR 120.115(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: Wires were properly spliced.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
Each grounding wire shall have green insulation. If a existing grounding wire that is not green is found, it shall be marked at both ends with green tape. -46 CFR 120.372(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: Grounds were properly attached.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
Remove "dead end" wires from all distribution panels, switch-boards, junction boxes, etc to the satisfaction of attending Marine Inspector. -46 CFR "Old T" 183.01-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: dead-end wires were removed or terminated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2020 Resolved
Illegal pigtail/shoretie found connected to engine room 110V/220V panel. Corrected on the spot. -46 CFR "Old T" 183.01-5
Action required: 60 - Rectify deficiencies prior to movement
Due 7 February 2020
Resolved 7 February 2020
Resolution: Immediately removed pigtail from panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2019 Resolved
Conduct casualty analysis report, repair transmission clutch actuator and conduct sea trials to the satisfaction of a USCG Marine Inspector. 46 CFR 155.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2019
Resolved 8 November 2019
Resolution: Replaced actuator and conducted sea trials.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 November 2019 Resolved
Identify fault on fire detection panel and properly repair detector / fire control panel. 46 CFR 115.810(a)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2019
Resolved 8 November 2019
Resolution: Fire detection equipment was serviced. ALL SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2019 Resolved
Starboard MDE has oil leak. Make permanent repairs to MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2019
Resolved 8 November 2019
Resolution: Vessel provided video footage attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2019 Resolved
Observed multiple electrical hazards in engine room; loose wires, dead end wires, loose/disconnected conduits, missing protective covers for breaker panel in galley, and multiple daisy-chained electrical extension chords. Make proper repairs to all electrical issues identified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Made proper repairs to issued identified during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2019 Resolved
Conduct satisfactory bilge pump and bilge system test in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Observed satisfactory test of bilge pump and bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 September 2019 Resolved
Found loose pressure gauge on the 471 Generator. Properly secure loose pressure gauge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Item secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2019 Resolved
Found numerous life jackets with improper vessel name marking. Properly mark life jackets with full vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Life jackets marked with vessel name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019 Resolved
Provide heat resistant specs for fuel sight gauges located on the port and starboard fuel tanks. If unable to provide specs, install heat resistant sight gauges with adequate protection to prevent damage to sight gauge. Fuel sight gauges must have automatic shut off devices in case of fuel line rupture.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 April 2020
Resolution: The sight gauge was removed and capped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2019 Resolved
Observed electrical panel cover located in concession stand on main deck have "zipties" as hinges. These ziptie hinges must be removed and replaced with proper hinges.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Zipties removed and replaced with proper support brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2019 Resolved
The bilge suction head located in Void 1C is missing bilge strainer. Install bilge strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Bilge strainer reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2019 Resolved
The hertz meter gauge located on the main switch board panel for service generator is not working. Repair/replace non functional hertz meter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: meter repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 September 2019 Resolved
Space storing carbon dioxide is missing proper warning sign. Place proper warning sign where carbon dioxide is stored i.a.w. 46 CFR 122.612(i)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Marking installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2019 Resolved
BILGE HIGH LEVEL ALARM IS NOT SECURELY ATTACHED. CITE: 46CFR182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 13 September 2019
Resolution: Bilge attached
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2019 Resolved
THE VESSEL QUEEN OF HEARTS IS A SPV-TL, THEREFORE NOT REQUIRED A SAFETY MANAGEMENT SYSTEM (SMS) PER REGULATION. SECTOR NY HAS FOUND THE FOLLOWING DEFICIENCIES TO BE OBJECTIVE EVIDENCE THAT A SERIOUS SUBSTANDARD CONDITION HAS NOT BEEN PRO-ACTIVELY MANAGED BY THE VESSEL'S OWNER/OPERATOR, LEADING TO A LACK OF SAFETY CULTURE ONBOARD THE VESSEL.
Action required: 30 - Ship detained
Resolved 13 September 2019
Resolution: Attneded vessel to conduct def follow-up and overall operation of vessel. All 701's were cleared to satisfaction of attending MI's. Re-issued vessels COI.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 August 2019 Resolved
REPAIRS OR ALTERATIONS TO THE HULL, MACHINERY, OR EQUIPMENT THAT AFFECT THE SAFETY OF THE VESSEL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT [name withheld] DISCOVERED IN LAZARETTE SPACE. VESSEL ENGINEER INITIALLY DENIED KNOWLEDGE OF UNAUTHORIZED REPAIR. UPON FURTHER QUESTIONING, HE ADMITTED TO KNOWLEDGE OF FLOODING AT THE RATE OF 3 CUPS PER MINUTE AND APPLYING AN UNAUTHORIZED EPOXY PATCH TO THE RUPTURE OOA 3 WEEKS AGO. NO REPAIR PLANS WERE SUBMITTED TO THE [name withheld] TEMPORARY REPAIR PROPOSAL AND TRANSIT PROPOSAL DELINEATING THE ROUTE AND MEASURES THAT WILL BE TAKEN ONBOARD TO ENSURE A SAFE TRANSIT, INCLUDING MITIGATING PROGRESSIVE FLOODING, TO A LOCAL SHIPYARD FOR PERMANENT REPAIRS.
Action required: 30 - Ship detained
Resolved 21 August 2019
Resolution: Proper repairs were made to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 14 August 2019 Resolved
WHENEVER THERE IS A HAZARDOUS CONDITION ONBOARD THE VESSEL, THE OWNER, MASTER, AGENT OR PERSON IN CHARGE SHALL IMMEDIATELY NOTIFY THE CAPTAIN OF THE PORT. NO REPORTS WERE MADE TO THE CAPTAIN OF THE PORT FOR THE RUPTURE LOCATED IN THE LAZARETTE SPACE. VESSEL ENGINEER ADMITTED TO KNOWLEDGE OF STEEL RUPTURE.
Action required: 30 - Ship detained
Resolved 21 August 2019
Resolution: Educated operator of reporting requirements
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2019 Resolved
THE BILGES AND OTHER SPACES MAY BE EXAMINED TO SEE THAT THERE IS NO EXCESSIVE ACCUMULATION OF OIL THAT MIGHT CREATE A FIRE HAZARD. EGREGIOUS ACCUMULATION OF APPROX. 2 GALLONS OF OIL DISCOVERED IN ENGINE ROOM BILGES. VESSEL REQUIRED TO PROVIDE CAUSAL ANALYSIS FOR SOURCE, EFFECT REPAIR, AND REMOVE OIL FROM ALL BILGES FOR INSPECTION.
Action required: 30 - Ship detained
Resolved 13 September 2019
Resolution: Bilges clean
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 August 2019 Resolved
AT EVERY VESSEL INSPECTION, QUARTERS, TOILET AND WASHING SPACES, GALLEYS, SERVING PANTRIES, LOCKERS, AND SIMILAR SPACES MAY BE EXAMINED TO DETERMINE THAT THEY ARE SERVICEABLE AND IN A SANITARY CONDITION. ALL AFOREMTIONED SPACES WERE FOUND TO BE IN DISARRAY AND IN AN UNSANITARY CONDITION. VESSEL MUST ENSURE ALL SPACES ARE CLEAN AND ORGANIZED TO MITIGATE THE RISK OF ENDANGERMENT TO CREW AND PASSENGERS. MAKE READY FOR INSPECTION.
Action required: 30 - Ship detained
Resolved 13 September 2019
Resolution: Cleaniness of all spaces were completed
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 August 2019 Resolved
ALL OBSERVED UNSAFE PRACTICES, FIRE HAZARDS AND OTHER HAZARDOUS SITUATIONS MUST BE CORRECTED. ALL 6 PORTABLE EXTINGUISHERS AND THE INSTALLED FIRE SUPPRESSION SYSTEM WERE DELINQUENT ON SERVICING AS OF JUNE 2019. ALL FIRE SAFETY EQUIPMENT MUST BE SERVICED TO INCLUDE A SATISFACTORY TEST OF INSTALLED FIRE PROTECTION SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Servcing of fixed and portable fire extinguishing systems were completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019 Resolved
ALL OBSERVED UNSAFE PRACTICES, FIRE HAZARDS AND OTHER HAZARDOUS SITUATIONS MUST BE CORRECTED. NUMEROUS ELECTRICAL HAZARDS EXIST ONBOARD INCLUDING DAISY-CHAINED POWER CORDS, EXPOSED WIRING IN ENCLOSURES, AND EXPOSED DEAD END WIRES IN LIGHTING. VESSEL MUST REMOVE DAISY-CHAINED POWER CORDS, PLACE DEAD COVERS IN ALL ENCLOSURES AND PLACE ALL EXPOSED WIRING IN AN ENCLOSURE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: ALl electrical issues were rectified
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 September 2019
Resolution: DAPI audit was completed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2018 Resolved
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 June 2022
Resolution: Operator demonstrated to MI while on inspection that AIS has been updated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 October 2018 Resolved
Vessel subject to hull inspection for superstructure and similar arrangements. Vessel stbd quarter damaged during docking maneuvers. Prepare and submit for approval repair plan to CG Marine Inspectors. Approval must be given prior to starting work.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2018
Resolved 26 October 2018
Resolution: Completed repairs see narrative.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2018 Resolved
Prepare and submit repair plan for two threaded openings in lazarette space (one port and one stbd).
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2018
Resolved 26 October 2018
Resolution: Completed repairs see narrative.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 September 2018 Resolved
Minimum capacity of fire pump shall be 50 gallons per minute at a pressure not less than 60 psi. Upon testing operation of vessels fire pump, the pumps psi gauge was reading a consistent 38 psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2018
Resolution: Vessel proved proper operation of fire pump.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2018 Resolved
Spaces containing flammable and combustible materials must have a fixed fire extinguishing system. Flammable and combustible materials were found throughout the vessel in unprotected spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2018
Resolution: Vessel removed all flammable and combustible materials.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
Vessel must have on board alcohol test strips . Alcohol test strips were expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2018 Resolved
Vessel more than 65 ft must carry on board 03 lifebuoys of 24 inches IAW 46 CFR 160.050 of Subchapter Q. One of vessel's lifebuoys had a hole and all of vessels lifebuoy lanyards are not of an approved type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2018
Resolution: Vessel replaced life buoy and all lanyards
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 4 September 2018 Resolved
Tubular sight glasses must be of heat resistant materials and have connections with devices that automatically close in the event of rupture. The port side fuel tank sight glass is not connected at all. It is wrapped around the port cover with a rag stuffed in the end. The connection devices do not automatically close. Rubber tubing used as sight glasses has not been proved to be heat resistant.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 4 September 2018 Resolved
MI identified a sewage leak in the toilet facility area. Toilet facility area is not in a sanitary condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
MI identified unsafe conditions throughout the vessel. A/C compressor units are not secured.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 September 2018 Resolved
Vessels fire detection system must comply with the regulations of this part. Vessels fire detection panel was displaying a troubleshooting alarm and crew was unable to rectify.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 September 2018 Resolved
Vessel must carry a first aid approved under 160.041 of Subchapter Q or a kit with equivalent contents or instructions. Vessel did not have an approved type first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Provided adequate kit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2018 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval from the cognizant OCMI. Vessel installed welding wire and LED lights and has changed the location/configuration of battery banks located in the engine room. Vessel is to submit an electrical line drawing to the OCMI and MSC for review and approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 2 June 2022
Resolution: MI verified that all plans have been submitted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2018 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MI identified splices and dead end wires throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Properly dead-ended wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2018 Resolved
An adult life jacket must be provided for each person on board the vessel. 8 life jackets were found to have deteriorated retro material. Total persons allowed is 416.
Action required: 705 - Other - as specified
Resolved 25 September 2018
Resolution: Purchased 8 new PFDs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed must be indicated by a durable marking at least 1 inch at the entranceway to that deck. Vessel did not have markings for 2nd and 3rd deck, both are limited by stability criteria.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: labeled decks properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2018 Resolved
All wires and cables must be ran as high as practical above the bilges. Battery cables were ran on the deck through out the bilges in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 17 March 2020
Resolution: Cables have been re-attached and run above the bilge.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
At each inspection bilges and other spaces may be examined for excessive accumulation of oil, trash , and debris that might create a fire hazard, clog bilge pumping system, or block emergency exits. There was an excessive amount of oil and debris found in the engine room bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 25 September 2018
Resolution: Bilges clean.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
At each inspection all observed unsafe practices or hazardous situations must be corrected. The aft stairs are not bolted down or secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Secured stairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2018 Resolved
Portable watertight containers for distress flares and smoke signals shall be clearly marked "DISTRESS SIGNALS". Vessel's portable container was unmarked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: labeled container.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 September 2018 Resolved
At each inspection, inspection of all accessible parts of the exterior and interior of the hull, watertight and weather-tight bulkheads and decks shall be prepared. The bulkhead to the forward deck is not weather-tight. There is a penetration from an ice machine line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Filled penetration with fire-stop.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 September 2018 Resolved
Piping conveying vapor, gas, or liquid of which temperature exceeds 150 degrees F must be insulated to prevent injuries. The exhaust piping on the port MDE is not fully insulated. It is only partially insulated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 23 October 2018
Resolution: Insulated piping.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 4 September 2018 Resolved
The cognizant OCMI may require any additional tests or inspections to determine that the vessel and its equipment are suitable for intended service. A significant flex in the deck located on the 2nd deck next to the balcony, port side was identified. Vessel is to sand down area and make ready for inspection for the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: tack welds under deck cracked- no concern for tripping hazard or impact to strength of deck. Stitch welds for deck surrounding all in tact.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2018 Resolved
Vessel has an expired VSP. Vessel is restricted to 150 passengers until provide vaild VSP.
Action required: 705 - Other - as specified
Due 20 August 2018
Resolved 23 August 2018
Resolution: Vessel submitted ASP Letter to MSC.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2018 Resolved
Remove wooden storage doors and replace with steel as original.
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 4 September 2018
Resolution: vessel removed wooden doors and replaced with then steel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 March 2018 Resolved
Vessel is past due for drydock inspection and is restricted from carrying passengers until credit drydock is completed by CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 September 2017 Resolved
Complete first annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2017
Resolution: Completed annual inspection.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 September 2017 Resolved
Prove processing of Certificate of Documentation application from NVDC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2017
Resolution: Attended vessel and operator had applying to renew the COD.
Documentation › Certificates/Documents › FCC SSL
Issued 5 September 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 7 September 2017
Resolution: Attended vessel and examined a valid FCC SSL.
Documentation › Logs/Records › Drug Test Records
Issued 5 September 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 September 2017
Resolution: Employees will not serve in a safety sesitive position until records are provided to the USCG.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 September 2017 Resolved
Post up to date and accurate fire control plan; make accessible to passengers.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 September 2017 Resolved
Re-label vessel name on life rings located on main and upper decks.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Electrical › Electric Supply System (service) › Battery Charger
Issued 5 September 2017 Resolved
Provide ammeter for wheelhouse battery charger.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 7 September 2017
Resolution: Attended vessel and digital meter was found acceptable.
Engineering › Bilge Water Management System › Strainer
Issued 5 September 2017 Resolved
Provide new strainer for bilge system in fuel tank void.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 13 September 2017
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 5 September 2017 Resolved
Prove proper operation of generator shut down pressure switch.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Electrical › Electric Supply System (service) › Battery Charger
Issued 5 September 2017 Resolved
Properly wire battery chargers in engine room.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Fire Fighting › Combustible Materials › Facings/Mouldings/Decorations/Veneers
Issued 5 September 2017 Resolved
Remove stowed carpet from from shaft space.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 5 September 2017 Resolved
Properly mount sewage pump in lazarette.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 13 September 2017
Engineering › Bilge Water Management System › Piping
Issued 5 September 2017 Resolved
Permanently attach remote forepeak valve for bilge system.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 5 September 2017 Resolved
Post emergency instructions IAW 46 CFR 122.510
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 5 September 2017 Resolved
Provide crew list & pre-employment documentation for Drug & Alcohol Program.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Personnel › Training › Passenger Safety
Issued 5 September 2017 Resolved
Designate senior deckhand in writing.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Stability › Unintentional Flooding › General
Issued 31 May 2016 Resolved
Vessel will not fill the fuel or sewage tanks more than 50% until damage stability is met.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new stability letter was issued.
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 4 July 2012 Resolved
Vessel lost propulsion
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2012
Resolution: Recieved marine engineers technicians report attesting bad fuel injector, repair and test.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 June 2012 Resolved
EV03 - Prove proper operation of E-Lights on Engine Room and port side 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Resolution: Vessel proved proper operation of emergency lighting fixtures.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 June 2012 Resolved
EV05 - Fix/install lighting in lazarette and shaft space.
Due 13 July 2012
Resolved 3 July 2012
Resolution: Vessel installed lighting in shaft space.
Engineering › Bilge Water Management System › Pump
Issued 29 June 2012 Resolved
EV01 - Prove proper operation (50 GPM) of vessel's bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Resolution: Vessel demonstrated satisfactory performance criteria for bilge system.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 June 2012 Resolved
EV06 - Install insulation on exhaust in shaft space.
Due 13 July 2012
Resolved 3 July 2012
Resolution: Vessel placed insulation on exhaust pipes.
Engineering › Sea-water System (primary cooling) › Piping
Issued 29 June 2012 Resolved
EV07 - Secure expansion tank pipe to/from P/S engines.
Due 13 July 2012
Resolved 3 July 2012
Resolution: Vessel secured expansion tank piping, and it is now free from movement.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 29 June 2012 Resolved
EV02 - Provide copy of current FCC Bridge to Bridge Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Resolution: Vessel showed FCC Bridge to Bridge Certificate.
Construction/Loadline › Structures › End Bulkhead
Issued 29 June 2012 Resolved
EV04 - Make bulkhead forward water tight in lazarette and shaft space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Resolution: Vessel made bulkheads watertight.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 15 August 2011 Resolved
Install mechanical interlock on main switchboard to prevent operation of both shore power and generators.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 24 August 2011
Resolution: Interlock installed.
Engineering › Bilge Water Management System › Valve
Issued 15 August 2011 Resolved
Replace bilge cut-off valve to forepeak space and prove proper operation of remote valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 24 August 2011
Resolution: Cut off valve replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2011 Resolved
Properly wrap and enclose wire nuts in electrical box on high level alarm wires in lazarette.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 24 August 2011
Resolution: Wire nuts properly enclosed.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 August 2011 Resolved
Replace bilge pump cables in shaft space with boat cable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 24 August 2011
Resolution: Cables replaced with proper type.
Electrical › Electrical Distribution System (service) › Cable
Issued 15 August 2011 Resolved
Properly hang depth sounder cable in tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 24 August 2011
Resolution: Depth sounder cable properly hung.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 15 August 2011 Resolved
Address oil leak and properly clean windings on forward generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 27 September 2011
Resolution: Windings on generator properly cleaned.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 March 2010 Resolved
Not to carry passengers until completing work list items for successful hull exam and 2 year dry-dock credit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 April 2010
Resolved 12 April 2010
Resolution: Received info for all repairs, issued 858 for dry-dock credit.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 August 2008 Resolved
Make proper repair to vessels emergency light – located fwd main deck.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 22 August 2008
Resolution: Corrected prior to departing vessel.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 August 2008 Resolved
Make proper repairs to vessel flood lights (03 total lights-01 on amidships stbd side and 02 bow).
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 August 2008 Resolved
Properly secure galley refrigerator as needed (falling hazard).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2008 Resolved
Properly blank unused sewage pipe located in lazerette space.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Construction/Loadline › Structures › Superstructure
Issued 22 August 2008 Resolved
Iinstall window molding for window at entry level IWO port side bow superstructure as noted. Window is loose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 August 2008 Resolved
Provide for cover on A/C thermostat, located port side lower deck as discussed.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 17 September 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 July 2008 Resolved
Provide (2) serviced BII fire extinguishers prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Vsl serviced the 2 fire extinguishers.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 July 2008 Resolved
Make repairs to port side dry exhaust pipe and properly support the same as discussed with marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Vsl made proper repairs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 July 2008 Resolved
Proof proper operation of second deck emergency light. (port side next to bar)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Light was fixed.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 9 July 2008 Resolved
Re-install cover for air conditioning unit on 3rd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Cover was installed properly.
Electrical › Electrical Distribution System (emergency) › Outlet Box
Issued 9 July 2008 Resolved
Replace electrical outlet box 3rd deck starboard forward.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Electrical outlet box was fixed.
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 9 July 2008 Resolved
Properly mount light switch boxes stbd forward.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2008
Resolution: Light Switch boxes were mounted properly.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 22 May 2007 Resolved
Permanently post fire control plan at operating station and on each deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Plan drafted and posted.
Fire Fighting › Firemans Outfit › Axe
Issued 22 May 2007 Resolved
Stow fire axe in or near operating station.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 24 May 2007
Engineering › Steering Gear System › Bracket/Clamp
Issued 22 May 2007 Resolved
Tighten the bearing clamps for the port and starboard rudder posts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Engineering › Steering Gear System › Linkage
Issued 22 May 2007 Resolved
Tighten the loose rudder linkage at the rams.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 May 2007 Resolved
Provide a bracket for the fire extinguisher in the galley and port side engine room (extinguisher too big for bracket).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Engineering › Fuel Oil Service System › Hose
Issued 22 May 2007 Resolved
All of the engines in the engine room have fuel oil and lube oil leaks, worn hoses, or unapproved hose. Fix all leaks and replace worn hoses with approved hose IAW 46 CFR 182.20-40.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Replaced with approved hoses.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 22 May 2007 Resolved
Replace the temperature sending unit wire (melted) on the port main engine.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 24 May 2007
Resolution: Wiring replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 May 2007 Resolved
Tighten all connections for all the batteries in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 May 2007 Resolved
Replace the bulging cooling hoses on the starboard main diesel engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Hose replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2007 Resolved
Remove the jury rigged fans on the upper deck forward (cords are run through the vent ducting).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Fans removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2007 Resolved
Remove the jury rigged wiring in the surveillance room (power strips and extension cords).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Power strips and cords removed.
Fire Fighting › Fire Pumps › Pressure
Issued 22 May 2007 Resolved
Prove proper operation of the fire pump to the satisfaction of USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: New fire pump installed.
Fire Fighting › Fire Main › Condition
Issued 22 May 2007 Resolved
Make proper repairs to secure leaking union on fire system piping in way of fire pump discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: Piping replaced from pump to branch lines out of engine room.
Fire Fighting › Fire Main › Condition
Issued 22 May 2007 Resolved
Make proper repairs to secure leak on fire system piping port side in way of engine room ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 May 2007
Resolution: Piping replaced from fire pump to branch lines out of engine room.
Electrical › Lighting (service) › Lighting Fixture
Issued 22 May 2007 Resolved
Replace light fixture in fuel tank space, starboard side.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 24 May 2007
Resolution: Fixtures replaced.
Engineering › Fuel Oil Service System › Valve, Control
Issued 22 May 2007 Resolved
Install nuts on the port and starboard main diesel engine fuel linkages.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Nuts installed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 22 May 2007 Resolved
Reinstall lagging on the forward generator exhaust.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 24 May 2007
Resolution: Lagging reinstalled.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 22 May 2007 Resolved
Repair the leaks on the sewage tank and make this space ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Space cleaned, gas/odor remains.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2007 Resolved
Remove the heaters over the bar on the upper deck or submit plans for approval prior to using the heaters.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Heaters removed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 May 2007 Resolved
Put the correct size fire extinguisher in the bracket in the surveillance room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 May 2007 Resolved
Make proper repairs to the port navigation light with UL 1105 compliant bulb. Vessel restricted to daylight ops only.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 24 May 2007
Resolution: Port navigation light replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 May 2007 Resolved
Replace starboard navigation light lens (lens is cloudy). Vessel restricted to daylight ops only.
Action required: 705 - Other - as specified
Due 5 June 2007
Resolved 24 May 2007
Resolution: Starboard navigation light replaced.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 May 2007 Resolved
Properly mark all life jacket stowage areas with number of jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Stowage numbers marked.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 May 2007 Resolved
Properly placard life jacket stowage areas with correct donning instructions for each style life jacket.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Instructions posted.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 May 2007 Resolved
Conduct man overboard drill in the presence of USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Satisfacory drill conducted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2007 Resolved
Replace the cable for the rudder angle indicator junction box port side aft upper deck.
Action required: 705 - Other - as specified
Due 2 July 2007
Resolved 27 June 2007
Resolution: New j-box/connections made.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 22 May 2007 Resolved
Install pipe hangers for the sewage space and double clamp all hose connections.
Action required: 705 - Other - as specified
Due 2 July 2007
Resolved 27 June 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 22 May 2007 Resolved
All of the portable extinguishers are stowed and can be removed, but some of them are in the wrong brackets. Correctly match all extinguishers with the approved brackets.
Action required: 705 - Other - as specified
Due 2 July 2007
Resolved 27 June 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 22 May 2007 Resolved
Replace broken fire pump gauge and prove proper operation to USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2007
Resolution: Gauge replaced.
Fire Fighting › Fire Main › Condition
Issued 16 August 2006 Resolved
Repair 02 leaks in fire pump suction line IWO port engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2006
Resolution: Fire pump suction line repaired.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 August 2006 Resolved
Obtain current copies of USCG Light List and US Coast Pilot publications.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 August 2006 Resolved
Install cover plate on junction box in shaft space.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 August 2006 Resolved
Install plugs in aft bulkhead penetrations in shaft space.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electric Supply System (service) › Cable
Issued 15 August 2006 Resolved
Repair oven power supply cord, prior to use.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 15 August 2006 Resolved
Repair/replace deckhead insulation in storage area behind bar, 1st deck.
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 August 2006 Resolved
Install cover and plugs for junction box in forepeak.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 15 August 2006 Resolved
Secure (permanently) electrical outlet and place wiring in receptacle on top deck, port side.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 August 2006 Resolved
Stencil life ring buoy with vessel name stowed on top deck, port side.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 11 October 2006
Lifesaving › Lifebuoys › Serviceable
Issued 15 August 2006 Resolved
Replace grab line on ring buoy stowed on top deck, port side.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 August 2006 Resolved
Secure junction box on AC unit, top deck forward of pilot house.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 August 2006 Resolved
Replace insulation in engine room on aft bulkhead and on overhead, near starboard side entrance, above engine room distribution panel.
Action required: 705 - Other - as specified
Due 6 September 2006
Resolved 11 October 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 August 2006 Resolved
Double clamp keel cooler flex hose on starboard main diesel engine (top, outboard side).
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 August 2006 Resolved
Enclose wiring in box for #2 air compressor in engine room.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Remove loose wire from battery charger on aft engine room bulkhead.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Properly dead-end/splice wires under bridge console.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Operations/Management › Pollution › Removal Methods/Procedures
Issued 15 August 2006 Resolved
Provide proof of waste management plan onboard vessel.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 August 2006 Resolved
Post COI and stability letter in view of passengers.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Operations/Management › Drills/Instruction › Safety Orientation
Issued 15 August 2006 Resolved
Provide passenger safety orientation pamphlet or announcement.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Fire Fighting › Firemans Outfit › Axe
Issued 15 August 2006 Resolved
Provide fire axe onboard vessel.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 11 October 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 August 2006 Resolved
Provide lifejacket donning placards applicable to lifejackets onboard vessel.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 August 2006 Resolved
Replace expired medications in first-aid kit.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 August 2006 Resolved
Replace forward masthead white light and stern light.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Properly connect hailer at bridge console.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 August 2006 Resolved
Properly label electrical panel in aft lower level bar.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Replace installation for A/C unit in aft lower level bar space.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2006 Resolved
Properly terminate/cap dead-end wires on main deck aft bar.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Fire Fighting › Fire Hoses › Condition
Issued 15 August 2006 Resolved
Replace 01 fire hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2006
Resolution: Fire hose replaced.
Fire Fighting › Fire Main › Condition
Issued 15 August 2006 Resolved
Repair leak on fire pump piping IWO main fire pump leaking profusely.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2006
Resolution: Pipe replaced.
Fire Fighting › Fire Main › Condition
Issued 15 August 2006 Resolved
Investigate source of leak for lower deck overhead leak IWO DJ booth.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2006
Resolution: Piping replaced.
Documentation › Certificates/Documents › FCC SSL
Issued 15 August 2006 Resolved
Provide valid station license and FCC Safety certificate. Vessel is restricted to 1000ft from shore.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 15 August 2006 Resolved
Provide retrotape for 40 adult lifejackets.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 August 2006 Resolved
Stencil vessel name on 05 lifejackets.
Action required: 705 - Other - as specified
Due 22 August 2006
Resolved 7 September 2006
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 24 August 2005 Resolved
Properly reinstall MSD pump in lazzarette
Condition: Damaged By Earlier Event
Due 1 September 2005
Resolved 7 September 2005
Resolution: Installed Same.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 August 2005 Resolved
Remove extension cord from dimmer switch box in pantry space.
Condition: Improper Installation
Due 1 September 2005
Resolved 7 September 2005
Resolution: Removed Same.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 August 2005 Resolved
Replace circuit breaker panel cover/door in service area behind main deck bar.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 August 2005 Resolved
Replace ice machine servicing panel in service area behind main deck bar.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 August 2005 Resolved
Prove operation of all emergency lighting aboard vessel.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Proved Proper Operation of Same.
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 August 2005 Resolved
Replace thermostat cover on main deck dance floor.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 August 2005 Resolved
Remove fan power cord from behind distribution panel on main deck dance floor.
Condition: Improper Installation
Due 1 September 2005
Resolved 7 September 2005
Resolution: Removed same.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 August 2005 Resolved
Replace all lighting fixture globes/cages on vessel.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2005 Resolved
Properly attach receptacle cover on 02 after deck overhead.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Reattached Same.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2005 Resolved
Install 110 volt receptacle outlet box for beer cooler on 02 afterdeck.
Condition: Improper Installation
Due 1 September 2005
Resolved 7 September 2005
Resolution: Installed Same.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 24 August 2005 Resolved
Remove staff uniforms from 02 afterdeck in way of emergency lighting pattern.
Condition: Placed in Improper Service
Due 1 September 2005
Resolved 7 September 2005
Resolution: Removed Same.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 24 August 2005 Resolved
Update tidal current/tide tables.
Condition: Unknown
Due 1 September 2005
Resolved 7 September 2005
Resolution: Updated same.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 August 2005 Resolved
Fax valid vessel master's license to captain of the port.
Condition: Unknown
Due 1 September 2005
Resolved 7 September 2005
Resolution: Reviewed Same.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 August 2005 Resolved
Properly secure loose bilge alarm panel in pilothouse.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Secured same.
Navigation › Piloting/Steering › Magnetic Compass
Issued 24 August 2005 Resolved
Provide proof of calibrated compass or provide the standard deviation tables.
Condition: Unknown
Due 1 September 2005
Resolved 7 September 2005
Resolution: Calibrated same.
Documentation › Logs/Records › Drug Test Records
Issued 24 August 2005 Resolved
Provide valid proof of drug and alcohol policy.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Provided Same.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 August 2005 Resolved
Provide proof of valid certificate of documentation.
Condition: Unknown
Due 1 September 2005
Resolved 15 September 2005
Resolution: COD provided.
Documentation › Markings/Placards › Capacity Marking
Issued 24 August 2005 Resolved
Properly placard 03 deck with maximum passenger capacity.
Condition: Damaged By Earlier Event
Due 1 September 2005
Resolved 7 September 2005
Resolution: Placarded Same.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 August 2005 Resolved
Properly replace engine room distribution panel
Condition: Damaged By Earlier Event
Due 1 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 August 2005 Resolved
Properly replace main distribution panel inside cover
Condition: Damaged By Earlier Event
Due 1 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 24 August 2005 Resolved
Install rubber matting in way of main distribution panel.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Installed Same.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 August 2005 Resolved
Replace receptacles at the bottom of the stbd side engine room ladder on the overhead.
Condition: Improper/Lack of Maintenance
Due 1 September 2005
Resolved 7 September 2005
Resolution: Replaced Same.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 August 2005 Resolved
Properly install door knobs/latching mechanisms on all stairwell/ fire boundary doors.
Condition: Improper Installation
Due 1 September 2005
Resolved 15 September 2005
Resolution: Fire doors installed to specifications.
Electrical › Electric Generation Source (service) › Generator
Issued 21 June 2004 Resolved
Repair 90KW generator and prove proper operation of overspeed trip and highwater temp alarms prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2004
Resolution: Received faxed attestation of repaired 120 KW generator from Vsl Master [name withheld] and vsl rep [name withheld] confirms high water temp shutdown, emergency shutdown, and low oil pressure shutdown; all sat.
Electrical › Electric Generation Source (service) › Generator
Issued 21 June 2004 Resolved
Repair 120KW generator and prove proper operation of overspeed trip and high water temp prior to carrying passengers.
Due 28 June 2004
Resolved 12 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 June 2004 Resolved
Properly dead-end wires in void underneath fwd bar.
Due 12 July 2004
Resolved 14 July 2004
Fire Fighting › Nozzles › Condition
Issued 21 June 2004 Resolved
Replace nozle on fwd fire station.
Due 12 July 2004
Resolved 12 July 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 June 2004 Resolved
Replace/repair and prove proper operation of emergency lighting on stbdside main deck.
Due 12 July 2004
Resolved 14 July 2004
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 21 June 2004 Resolved
Tighten packing on stbd shaft.
Due 12 July 2004
Resolved 12 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 June 2004 Resolved
Properly hang/support all electrical wires (every 24in).
Due 12 July 2004
Resolved 14 July 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 21 June 2004 Resolved
Ventilate sewage space and make ready for CG inspection.
Due 12 July 2004
Resolved 12 July 2004
Accommodation/Occupational Safety › Messroom › Location
Issued 21 June 2004 Resolved
Repair dripping sink/overhead food bar. Drip pan in void under bar (bar compartment).
Due 12 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 June 2004 Resolved
Properly dead end wires in tank space.
Due 12 July 2004
Resolved 14 July 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 21 June 2004 Resolved
Place fire extinguishers in brackets.
Due 12 July 2004
Resolved 14 July 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 June 2004 Resolved
Properly mark all ring lifebuoys w/ vsl name.
Due 12 July 2004
Resolved 14 July 2004
Construction/Loadline › Structures › End Bulkhead
Issued 21 June 2004 Resolved
Replace cracked bridge window, portside.
Due 12 July 2004
Resolved 14 July 2004
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 June 2004 Resolved
Place hailing port & vsl name on stern.
Due 12 July 2004
Resolved 14 July 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 June 2004 Resolved
Prove proper operation of bilge high level alarm in shaft space. Crew required to make 30 minutes rounds of void spaces and captain required to make log entries of such until deficiency is cleared by CG MI.
Due 14 July 2004
Resolved 14 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 June 2004 Resolved
Properly connect wiring in shaft space and mount bilge float switch.
Due 14 July 2004
Resolved 14 July 2004
Fire Fighting › Structural Fire Protection - General
Issued 27 April 2004 Resolved
Finish structural fire protection in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2004
Resolution: Structural fire portection finished.
Electrical › Electrical Distribution System (service)
Issued 23 June 2003 Resolved
Remove all power strips and extension cords and properly configure DJ electrical equipment LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 30 June 2003
Resolved 24 June 2003
Personnel › Certificates/Documents/Licenses
Issued 15 May 2003 Resolved
Provide copy of Senior Deckhand Letter. LEGACY COMPONENT DESC: Senior Deckhand Letter
Due 22 May 2003
Resolved 23 June 2003
Navigation › Piloting/Steering
Issued 15 May 2003 Resolved
Provide updated copy of magnetic deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Due 15 June 2003
Resolved 23 June 2003
Stability
Issued 15 May 2003 Resolved
Post sign for maximum 100 passengers on upper deck/Remove 200 passenger signs.
Due 22 May 2003
Resolved 23 June 2003
Construction/Loadline › Penetrations
Issued 15 May 2003 Resolved
Install cut-off valve in forepeak accessible from weatherdeck or next void space aft of collision bulkhead. LEGACY COMPONENT DESC: Cut-Off valve for bilge piping to fwd void
Due 15 June 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 15 May 2003 Resolved
Install junction box in lazerett space to properly connect electrical wires. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 15 May 2003 Resolved
Replace broken conduit in lighting system in lazerett. LEGACY COMPONENT DESC: Conduit
Due 22 May 2003
Resolved 23 June 2003
Electrical › Lighting (service)
Issued 15 May 2003 Resolved
Replace lighting in lazerett on stbd side. LEGACY COMPONENT DESC: Lighting Fixture
Due 22 May 2003
Resolved 23 June 2003
Accommodation/Occupational Safety › Washroom/Toilet
Issued 15 May 2003 Resolved
Repare broken urinal in head. Urinal is leaking into lazerett. LEGACY COMPONENT DESC: Toilet
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 23 June 2003
Accommodation/Occupational Safety › Ventilation
Issued 15 May 2003 Resolved
Ventilate lazerett due to leaking urinal. LEGACY COMPONENT DESC: Lazerett
Due 22 May 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 15 May 2003 Resolved
Properly connect electrical wire to sewage pump. LEGACY COMPONENT DESC: Wiring
Due 22 May 2003
Resolved 23 June 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 15 May 2003 Resolved
Place handles to fuel cut-out valves outside the tank space or provide proper flame protection. LEGACY COMPONENT DESC: Valve
Due 15 June 2003
Resolved 23 June 2003
Fire Fighting
Issued 15 May 2003 Resolved
Properly install fire axe holder on port side IWO E/R entrance. LEGACY COMPONENT DESC: Fire Axe holder
Due 22 May 2003
Resolved 23 June 2003
Electrical › Electrical Distribution System (service)
Issued 15 May 2003 Resolved
Replace inside cover to electrical panel in E/R IWO stbd entrance. Inside cover is not 100% dead-face. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 23 June 2003
Operations/Management › Drills/Instruction
Issued 22 May 2002 Resolved
Provide USCG with record of crew training/drills. Conduct underway man overboard drill to satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Drills & records sat.
Engineering › Compressed Air System (control)
Issued 22 May 2002 Resolved
Provide [name withheld] with plan submittal for new air compressor/receiver installation. LEGACY COMPONENT DESC: Compressor
Condition: Placed in Improper Service
Due 4 June 2002
Resolved 10 July 2002
Resolution: Plans have been submitted to the ACTNY PR office. MBZ
Engineering › Fuel Oil Storage/Transfer System
Issued 22 May 2002 Resolved
Provide 30x30 mesh screening for port side fuel vent. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Vent screen installed.
Engineering › Compressed Air System (control)
Issued 22 May 2002 Resolved
Permanently mount new air receiver and provide compressor belt guard. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Placed in Improper Service
Due 4 June 2002
Resolved 6 June 2002
Resolution: Belt guard and receiver properly installed.
Electrical › Electric Generation Source (service)
Issued 22 May 2002 Resolved
Prove proper operation of 125KW generator overspeed trip device. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 4 June 2002
Resolved 6 June 2002
Resolution: O/S trip test sat.
Engineering › Compressed Air System (control)
Issued 22 May 2002 Resolved
Make forward air receiver ready for internal or hydrostatic test inspection. Conduct operational test of relief valve. LEGACY COMPONENT DESC: Receiver/Bottle
Condition: Improper/Lack of Maintenance
Due 4 June 2002
Resolved 6 June 2002
Resolution: Satisfactory internal exam conducted.
Electrical › Electrical Distribution System (service)
Issued 22 May 2002 Resolved
Properly label controllers in engine room. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Controllers labeled.
Electrical › Lighting (service)
Issued 22 May 2002 Resolved
Replace missing light guard in engine room, stbd side. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Light guard installed.
Accommodation/Occupational Safety › Ventilation
Issued 22 May 2002 Resolved
Repair port side ventilator trunk on main deck. LEGACY COMPONENT DESC: Trunk
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Ventilation trunk secured.
Construction/Loadline › Hull
Issued 22 May 2002 Resolved
Plug hole in shaft alley bulkhead, port side. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Bulkhead penetration sealed.
Engineering › Bilge Water Management System
Issued 22 May 2002 Resolved
Prove ability to dewater forepeak with installed bilge system. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Bilge system test sat.
Navigation › Piloting/Steering
Issued 22 May 2002 Resolved
Provide current USCG Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Unknown
Due 4 June 2002
Resolved 6 June 2002
Resolution: Light list provided.
Engineering › Sea-water System (primary cooling) › Valve
Issued 19 March 2002 Resolved
Replace both the 3 inch ball fire main sea valve and the 1 inch ball MSD intake sea valve due to deep pitting of the ball surface.
Condition: Unknown
Due 19 March 2002
Resolved 19 March 2002
Resolution: Both sea valves replace with new valves of the same type and kind.
Engineering › Steering Gear System › Rudder Stock
Issued 11 March 2002 Resolved
Replace worn ruder stock gudgeon bearing on the starboard rudder.
Condition: Unknown
Due 11 March 2002
Resolved 11 March 2002
Resolution: Worn bearing was replaced.
Electrical
Issued 21 May 2001 Resolved
Remove excess wiring and extention cords, and install acceptable wiring outlets with circuit protection on the third deck.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Electrical
Issued 21 May 2001 Resolved
Install UL approved matting in front of main switchboard.
Condition: Unknown
Due 21 May 2001
Resolved 21 May 2001
Electrical
Issued 21 May 2001 Resolved
Repair oil temp guage on Forward generator.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Install Data plate for Forward generator.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Engineering
Issued 21 May 2001 Resolved
Install a flame inpingement bowl on forward center racor filter.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Remove foam wire/hose sheathing on all MDE and generator sets, Install acceptable marine grade hose/wire insulation as needed.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Repair hertz meter on Forward generator set.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Remove and properly terminate dead end wiring on the bridge.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
PROVIDE PROOF OF OPERATION FOR LOW LUBE OIL TRIPS ON GENERATORS.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Construction/Loadline
Issued 21 May 2001 Resolved
Prove proper operation of valve and repair or replace broken handle.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Electrical
Issued 21 May 2001 Resolved
Remove or provide proper wiring installation for fan in galley and for fan_x001C_at portside of engineroom.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Remove/properly terminate deadend wiring in galley.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Engineering
Issued 21 May 2001 Resolved
Repair flame screen on fuel tank vent stbd side.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Electrical
Issued 21 May 2001 Resolved
Remove or provide proper wiring installation for auxillary water in Engineroom.
Condition: Unknown
Due 8 June 2001
Resolved 8 June 2001
Documentation
Issued 8 June 2000 Resolved
Change O/O information on DOC to reflect current info.
Condition: Unknown
Due 8 July 2000
Resolved 29 June 2000
Documentation
Issued 8 June 2000 Resolved
Post crew station bill in location visible to crewmembers.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Documentation
Issued 8 June 2000 Resolved
Post passenger safety bill in location visible to passengers.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Documentation
Issued 8 June 2000 Resolved
Show proof of CPR training for at least one member of crew.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Fire Fighting
Issued 8 June 2000 Resolved
Repair port engine room fire door to ensure full closure, repair closure devices of both doors to allow them to latch in the closed position.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Electrical
Issued 8 June 2000 Resolved
Repair ships public address system
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Fire Fighting
Issued 8 June 2000 Resolved
Show proof of acceptable fire resistance of interior furnishings in regardsto carpeting thru-out vessel, wall paper wall coverings and pilothouse noise suppression insulation installation (all newly installed furnishings).
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Accommodation/Occupational Safety
Issued 8 June 2000 Resolved
Post passenger emergency evacuation instruction plan in location visible topassengers.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Lifesaving
Issued 8 June 2000 Resolved
Install exit signs at passenger exits and mark doors with appripriate labels.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Accommodation/Occupational Safety
Issued 8 June 2000 Resolved
Remove exceptional amount of excess combustibles throughout vessel to remove potentials of fire hazards due to large amount of flammables and combustible materials stored thru-out vessel. General housekeeping.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
Repair broken galley windows, aft bulkhead, from paddle wheel damages.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Engineering
Issued 8 June 2000 Resolved
Remove broken blade on ornamental paddle wheel to prevent further structural damage as wheel rotates with loose blades.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Construction/Loadline
Issued 8 June 2000 Resolved
Repair inoperative zone 2 bilge alarm.
Condition: Unknown
Due 8 June 2000
Resolved 8 June 2000
Navigation
Issued 26 May 1999 Resolved
PROVIDE DAY SHAPE FOR ANCHORING. 20" BALL.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 26 May 1999 Resolved
SUBMIT PLANS FOR HIGH LEVEL ALARM SYSTEM TO INCLUDE ALL ITEMS INSTALLED/WIRING SIZE/AND LOCATION OF SYSTEM IN VSL.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Lifesaving
Issued 26 May 1999 Resolved
INSTALL A LENSE ON MAIN DECK PORT SIDE EMERGENCY LIGHT. LENSE MISSING, LIGHT OPERATED SAT.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Fire Fighting
Issued 26 May 1999 Resolved
INSTALL A NEW GAUGE ON FIRE PUMP.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Accommodation/Occupational Safety
Issued 26 May 1999 Resolved
BRIDGE/PILOT HOUSE: REPLACE PORT AND STBD SIDE WINDOWS BOTH CRACKED
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Electrical
Issued 26 May 1999 Resolved
INSTALL BLANKS IN 110V POWER PANEL, LOCATED IN SODA FOUNTAIN ROOM STBD, FWDBULKHEAD
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Construction/Loadline
Issued 26 May 1999 Resolved
ALL HIGH LEVEL ALARM FLOAT SWITCHES MAKE CONNECTIONS WATER TIGHT DUE TO LOCATION IN BILGES.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Lifesaving
Issued 4 June 1998 Resolved
PROVIDE AN ADDITIONAL CHILD SIZE LIFEJACKETS
Condition: Unknown
Due 4 June 1998
Resolved 4 June 1998
Construction/Loadline
Issued 4 June 1998 Resolved
PROPERLY POST MAX PASSENGER CAPACITY OF UPPER AND #1 DECK
Condition: Unknown
Due 4 June 1998
Resolved 4 June 1998
Lifesaving
Issued 4 June 1998 Resolved
PROPERLY STENCILED LIFEJACKET LOCKERS.
Condition: Unknown
Due 4 June 1998
Resolved 4 June 1998
Construction/Loadline
Issued 15 April 1998 Resolved
MAKE PERMANENT REPAIRS TO BILGE PIPING IN 2ND COMPARTMENT FWD OF STERN IN WAY OF TEMP REPAIRS USING RUBBER GASKETS AND CLAMPS.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Documentation
Issued 14 April 1997 Resolved
PROVIDE LICENSE OF MASTER.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Unknown
Issued 14 April 1997 Resolved
PROPERLY MARK VESSEL WITH VESSEL'S CORRECT NAME
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Unknown
Issued 14 April 1997 Resolved
PROVIDE DECK LOG FOR TRAINING.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Documentation
Issued 14 April 1997 Resolved
PROVIDE PROOF OF DOCUMENT RENEWAL
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Fire Fighting
Issued 14 April 1997 Resolved
INSTALL NEW PRESSURE GAUGE ON FIRE PUMP.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Electrical
Issued 14 April 1997 Resolved
PROVIDE PROOF OF PROPER OPERATION OF AFT GENERATOR
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Lifesaving
Issued 4 June 1996 Resolved
PROVIDE BRIGHTLY COLORED DISTRESS SIGNAL CASE WITH MARKINGS AS PER 46 CFR 122.614.
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Unknown
Issued 4 June 1996 Resolved
CONDUCT OVSPD TRIP TEST ON 125KW GENERATOR IN PRESENCE OF A MARINE INSPECTOR OR FAX WRITTEN PROOF OF TEST TO INSPECTION AND COMPLIANCE BRANCH ACTIVITIES NEW YORK.
Condition: Unknown
Due 20 June 1996
Resolved 31 July 1996
Lifesaving
Issued 4 June 1996 Resolved
PROVIDE RETROREFLECTIVE TAPE FOR RING BUOY FWD PORT SIDE SECOND DECK.
Condition: Unknown
Due 4 June 1997
Resolved 17 June 1996
Navigation
Issued 4 June 1996 Resolved
REPLACE EXISTING NAV LIGHTS WITH LIGHTS THAT MEET UL STANDARD 1104.
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Lifesaving
Issued 4 June 1996 Resolved
RENEW RETROREFLECTIVE TAPE ON 166 PFDs. PASSENGER CARRIAGE IS REDUCED TO 334 ADULTS UNTIL THIS ITEM IS CLEARED BY A MARINE INSPECTOR.
Condition: Unknown
Due 6 June 1996
Resolved 17 June 1996
Lifesaving
Issued 27 April 1996 Resolved
REMOVE EXCESS BUCKETS OF OIL FROM ENGINEROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1996
Resolved 27 June 1996
Electrical
Issued 27 April 1996 Resolved
LABEL ELECTRICAL PANELS
Condition: Unknown
Due 6 June 1996
Resolved 23 June 1996
Fire Fighting
Issued 27 April 1996 Resolved
SECURE LEAK AT FIRE PUMP SUCTION STRAINER._x001C_
Condition: Unknown
Due 6 June 1996
Resolved 23 June 1996
Electrical
Issued 27 April 1996 Resolved
SECURE CABLE TO BATTERY POWERED LIGHT IN ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 June 1996
Resolved 23 June 1996
Electrical
Issued 27 April 1996 Resolved
INSTALL COVERS OVER BATTERY BOXES IN ER.
Condition: Unknown
Due 23 June 1996
Resolved 23 June 1996
Electrical
Issued 27 April 1996 Resolved
SUBMIT PLANS FOR RENEWED SECTIONS OF ELECTRICAL INSTALLATION FOR [name withheld].
Condition: Unknown
Due 6 June 1996
Resolved 23 June 1996
Electrical
Issued 27 April 1996 Resolved
PROVIDE PROTECTIVE GUARDS FOR FLUORESCENT LIGHTS.
Condition: Unknown
Due 6 June 1996
Resolved 31 July 1996
Deck/Cargo
Issued 6 June 1995 Resolved
PROVIDE COPY OF VALID COD STICKER.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Navigation
Issued 6 June 1995 Resolved
PROVIDE COPY OF CHARTS FOR ROUTE INDICATED ON COI.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Construction/Loadline
Issued 6 June 1995 Resolved
MARK STBD STERN W/VSL NAME AND HOMEPORT.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Lifesaving
Issued 6 June 1995 Resolved
RE-MARK ALL RING BOUYS WITH VSL NAME.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Unknown
Issued 6 June 1995 Resolved
PROVIDE PROOF OF MEMBERSHIP IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Electrical
Issued 6 June 1995 Resolved
FIX STBD STERN W/VSL NAME AND HOME PORT.
Condition: Unknown
Due 20 July 1995
Resolved 20 July 1995
Construction/Loadline
Issued 3 March 1995 Resolved
Crop and renew 18"x18" section of aft stbd engien room bulkhead in way of temp repairs to appox 1" hole.
Condition: Unknown
Due 3 April 1995
Resolved 16 March 1995
Documentation
Issued 4 March 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Construction/Loadline
Issued 2 December 1993 Resolved
MAKE REPAIRS OR REMOVE FROM VESSEL BOW RAMP.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Construction/Loadline
Issued 2 December 1993 Resolved
MAKE REPAIRS TO FORWARD MAST AND RAILING ON 01 DECK FORWARD.
Condition: Unknown
Due 2 December 1993
Resolved 2 December 1993
Engineering
Issued 8 July 1993 Resolved
PROVIDE SUPPLY DUCTS FOR VENTILATION TO THE MACHINERY COMPARTMENT WITH COWLS OR SCOOPS. THIS IS TO BE DONE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR AT NEXT DRYDOCK, BUT NO LATER THAN 31OCT93. (182.20-45(C)
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Engineering
Issued 8 July 1993 Resolved
INSTALL EXHAUST DUCT EXTENDING TO A POINT NEAR THE BOTTOM OF THE MACHINERY COMPARTMENT. THIS IS TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR AT THE NEXT DRYDOCK, BUT NO LATER THAN 31OCT93.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Construction/Loadline
Issued 8 July 1993 Resolved
PROVIDE DRAWING OF AMOUNT + PLACEMENT OF FOAM BLOCKS FROM KRAMER + BEST _x001C_ #X-2 A.H.O. BY NEXT DRYDOCKING BUT NO LATER THAN 31OCT93.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Engineering
Issued 20 April 1993 Resolved
PROVIDE EXHAUST LAGGING FOR ALL FOUR MAIN ENGINE EXHAUSTS FROM MANIFOLD AFT.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Electrical
Issued 20 April 1993 Resolved
REMOVE ALL DEAD END WIRING, MOUNT ALL LOOSE WIRING, AND PROVIDE COVER FOR BREAKER BOX STBD SIDE ENGINE ROOM.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Engineering
Issued 20 April 1993 Resolved
FIND AND REPAIR EXHAUST LEAK IN COMPARTMENT AFT OF ENGINE ROOM IN MAIN ENGINE EXHAUST.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Engineering
Issued 20 April 1993 Resolved
REPAIR OR REPLACE BOTH MAIN ENGINE TACKOMETERS IN WHEELHOUSE.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Engineering
Issued 20 April 1993 Resolved
PROVIDE GUARDS FOR FRONT PULLEYS ON BOTH MAIN ENGINES AND BOTH GENERATORS.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Lifesaving
Issued 28 April 1992 Resolved
VSL REQUIRED TO OBTAIN 1 RING BUOY.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Construction/Loadline
Issued 28 April 1992 Resolved
MUST FREE UP HANDLE TO FOREPEAK SUCTION VALVE.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Lifesaving
Issued 28 April 1992 Resolved
VSL REQUIRED TO OBTAIN 2 ORANGE SMOKE SIGNALS.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Fire Fighting
Issued 1 May 1991 Resolved
OBTAIN MOUNTING BRACKETS FOR ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991 Resolved
REPLACE THE INSULATION BLANKETS ON THE PORT ENGINE EXHAUST LINE IN THE SHAFT ALLEY.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Navigation
Issued 1 May 1991 Resolved
OBTAIN ANCHOR BALL.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991 Resolved
REPLACE MISSING GLOBES AND GUARDS ON LIGHTS.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991 Resolved
STENCIL FUEL TANKS FOR IDENTIFICATION.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Navigation
Issued 1 May 1991 Resolved
REPLACE COVER GASKET ON STARBOARD SIDELIGHT.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Accommodation/Occupational Safety
Issued 1 May 1991 Resolved
REPAIR LEAK IN BAR SINK DRAIN IN FUEL TANK COMPARTMENT.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991 Resolved
MAKE ALL ELECTRICAL CONNECTIONS IN THE ENGINEROOM WATERTIGHT.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Navigation
Issued 1 May 1991 Resolved
MAKE ANCHOR LIGHT OPERABLE.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991 Resolved
REMOVE DEAD WIRING FROM ENGINEROOM.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991 Resolved
REMOVE OIL FROM ENGINEROOM BILGES.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991 Resolved
REPAIR LEAK IN STARBOARD ENGINE EXHAUST LINE AT MAIN DECK.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Accommodation/Occupational Safety
Issued 1 May 1990 Resolved
PROVIDE A PIPE CAP (MISSING) FOR THE MSD TYPE III HOLDING TANK PUMP OUT FITTING.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990 Resolved
PROVE PROPER OPERATION OF THE SHIPS SERVICE MAIN ELECTRICAL CONTROL PANEL FWD GENERATOR, AFT GENERATOR AND SHORE TIE SWITCHES, (SWITCHES CAN NOT BE CONTROL FROM OUTSIDE OF THE ELECTRICAL CONTROL BOARD).
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990 Resolved
REMARK ALL (03) RING BUOYS WITH VESSELS HULL NAME.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990 Resolved
PROVIDE V-BELT GUARDS ON BOTH PORT AND STBD MAIN DIESEL ENGINES, AND BOTH FWD AND AFT DIESEL GENERATORS.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990 Resolved
REMOVE DEAD 12V WIRING DEAD ENDS FOR BOTH MAIN DIESEL ENGINE CONTROL PANELSAND FWD GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 1 May 1990 Resolved
REPAIRED CRACKED WINDOWS IN THE PILOT HOUSE.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Accommodation/Occupational Safety
Issued 1 May 1990 Resolved
PROVIDE A PIPE CAP FOR THE STBD SIDE FRESH WATER FILL PIPE.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990 Resolved
REPAIR BROKEN EMERGENCY LIGHTING FIXTURES THROUGH OUT THE VESSEL, (DECKS, ENGINE COMPARTMENT AND MAIN CABIN).
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 1 May 1990 Resolved
EFFECT PERMANENT REPAIRS TO BOTH THE PORT AND STBD PADDLE WHEEL SADDLE BEARINGS SUPPORT BRACKETS/PLATING, (APPARENTLY PADDLE WHEEL SHAFT WAS RAISED AND SUPPORT BRACKETS ARE NOW FASTENED WITH NYLON LINE).
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 1 May 1990 Resolved
EFFECT PERMANENT REPAIRS TO BOTH THE PORT AND STBD PADDLE WHEEL SADDLE BEARING/SHAFT PROTECTIVE GUARDS.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Construction/Loadline
Issued 1 May 1990 Resolved
EFFECT PERMANENT REPAIRS TO THE CRACKED WELDS ON THE OUTER DECK PADDLE WHEEL SUPPORT DECKING, STBD SIDE, AFT STBD QUARTER OF MAIN HOUSE, (CRACKED WELDS ON EXISTING WELD REPAIRS).
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Navigation
Issued 1 May 1990 Resolved
EFFECT PERMANENT REPAIRS TO BOTH THE PORT AND STBD HYDRAULIC STEERING APPARATUS RAMS, (CYLINDERS LEAKING HYDRAULIC OIL FROM SEALS AND OR HOSES).
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990 Resolved
REPLACE MISSING OUTER DECK LIGHTING FIXTURES.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 1 May 1990 Resolved
REPLACE MISSING AFT GENERATOR ELECTRICAL CONTROL PANEL BLANKS.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Accommodation/Occupational Safety
Issued 1 May 1990 Resolved
FASTEN THE COPPER RADIATOR DRAIN TUBING IN THE ENGINE COMPARTMENT OVERHEAD.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Accommodation/Occupational Safety
Issued 1 May 1990 Resolved
EFFECT PERMANENT REPAIRS TO THE STBD SIDE LUBE OIL STOWAGE TANK FILL STAND PIPE AND VENT LINE.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Accommodation/Occupational Safety
Issued 1 May 1990 Resolved
EFFECT PERMANENT REPAIRS TO THE AFT PORT LADDER, (FROM 01 DECK TO MAIN DECKSTEP'S 1,2, AND 3.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Electrical
Issued 3 May 1989 Resolved
REMOVE OR CORRECTLY INSTALL THE ELECTRICAL LIGHT IN THE AFTER VOID. (DROP LIGHT)
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Electrical
Issued 3 May 1989 Resolved
PROPERLY CONNECT THE HOT WATER HEATER IN THE MEN'S HEAD, ELECTRICAL CONN.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Electrical
Issued 3 May 1989 Resolved
INSTALL THE CIRCUIT BREAKER GUARD COVERS IN THE ELECTRIC DISTRIBUTION PANEL#1, 2A, AND ENGINE ROOM.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Electrical
Issued 3 May 1989 Resolved
REMOVE THE NON-APPROVED ELECTRICAL PLUGS FROM THE WOMEN'S AND MEN'S HEAD ONTHE MAIN DECK.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Electrical
Issued 3 May 1989 Resolved
PROPERLY INSTALL THE ELECTRICAL SUPPLY WIRE FOR THE SHAFT ALLEY VOID COMPARTMENT BILGE SUMP PUMP.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 3 May 1989 Resolved
REPAIR THE EXHAUST LEAK AND REINSTALL LAGGING FOR THE #1 MDE DRY EXHAUST IN THE SHAFT ALLEY VOID.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 3 May 1989 Resolved
INSTALL THE HEAT DEFLECTOR SHIELD ON THE CENTERLINE RACOR FUEL FILTER WHERE MISSING.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Electrical
Issued 3 May 1989 Resolved
RENEW THE BROKEN TOPPED #1 MDE STARTING BATTERY.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 3 May 1989 Resolved
RENEW THE FUEL OIL TANK FLAME SCREENS FOR THE PORT AND STBD FUEL OIL TANKS.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Electrical
Issued 3 May 1989 Resolved
INSTALL MISSING CIRCUIT BREAKER BLANK IN THE #2 ELECTRIC DISTRIBUTION PANEL.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Unknown
Issued 4 May 1988 Resolved
PROVIDE SAFETY RELIEF VALVE ON FRESH WATER PRESSURE TANK.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Electrical
Issued 4 May 1988 Resolved
REWIRE ELECTRIC BILGE PUMP WITH PROPER SIZE AND APPROVED TYPE WIRING, IN WAY OF 2ND COMPT. FROM AFT.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Unknown
Issued 4 May 1988 Resolved
PROVIDE 3 HAND HELD RED FLARES/DISTRESS SIGNAL IN GOOD CONDITION.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Accommodation/Occupational Safety
Issued 4 May 1988 Resolved
REPAIR GREY WATER LINE FROM THE SINK TO THE BAR AT MAINDECK IN WAY OF FUEL TANK COMPARTMENT NOT LATER THAN SCHEDULED DRYDOCKING.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Engineering
Issued 4 May 1988 Resolved
REPAIR EXHAUST PIPE LEAKING IN WAY OF COMPARTMENT AFT OF ENGINE ROOM, STBD SIDE EXHAUST PIPE NO LATER THAN THE NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Electrical
Issued 7 May 1987 Resolved
MAKE OPERABLE THE 3 BATTERY OPERATED RELAY LANTERNS LOCATED AT THE P&S 2-ND DECK AND ENGINEROOM.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Navigation
Issued 7 May 1987 Resolved
PROVIDE A NEW MAGNETIC COMPASS.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Accommodation/Occupational Safety
Issued 7 May 1987 Resolved
PROVIDE A SAFETY SHIELD IN WAY OF THE 2-ND DECK OVER LOOKING THE PADDLE WHEEL.
Condition: Unknown
Due 7 May 1987
Resolved 7 May 1987
Electrical
Issued 5 March 1985 Resolved
PLACE LAGGING ON EXHAUST PIPING OF GENERATOR.
Condition: Unknown
Due 5 March 1985
Resolved 5 March 1985
Electrical
Issued 5 March 1985 Resolved
REMOVE SCREW CONNECTORS THRU OUT VESSEL AND REPLACE WITH PROPER CONNECTORS.
Condition: Unknown
Due 5 March 1985
Resolved 5 March 1985

Casualty record · 6

8 February 2011Routine · role: Involved in a Marine Casualty · activity 3961422
4 June 2011Routine · role: Involved in a Marine Casualty · activity 4036918
4 July 2012Routine · role: Involved in a Marine Casualty · activity 4368418
29 August 2012Routine · role: Involved in a Marine Casualty · activity 4426998
4 November 2019Routine · role: Involved in a Marine Casualty · activity 6849421
6 May 2023Routine · role: Involved in a Marine Casualty · 1 injured · activity 7809831
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

FIRST LADY (2011–2012), QUEEN OF HEARTS (2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.