BOSS LADY NYC

BOSS LADY NYC is a 1983 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in March 2026, along with 99 deficiencies, 3 operational controls and 6 casualty investigations between 2011 and 2023.

Records from 2011 to 2026. Most recent: inspection, 20 March 2026.

Built
1983
Last inspected
20 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3673
217332
Flag
UNITED STATES
Maury page id
psix-217332

Documentation record

Registered dimensions (L × B × D)90.0 ft × 32.0 ft × 3.8 ft
Registered tonnagegross 91 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJ. HUBERT BONNER · MILLBROOK, AL, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portJERSEY CITY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JULIETTE Passenger (Inspected) · MISLE 179215 · 4 November 2019 · activity 6849421JUSTINE Passenger (Uninspected) · MISLE 299707 · 4 November 2019 · activity 6849421

Inspection history · 27

20 March 2026 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8327267
25 August 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8217380
29 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7991750
25 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7901148
30 August 2023 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7780894
31 May 2023 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7704908
6 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7809831
2 June 2022 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7464784
2 May 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7442382
19 November 2021 COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7348969
4 June 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215677
4 February 2020 In-Service Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6903082
4 November 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849421
4 November 2019 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6849428
9 September 2019 MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6807206
22 August 2019 DAPI Audit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6792457
14 August 2019 Damage Survey · In-Service Inspection · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6783254
2 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6573193
21 October 2018 Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6565338
4 September 2018 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6531542
20 August 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6518143
5 April 2018 Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6373004
2 March 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6364673
10 January 2018 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6335636
5 September 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6260225
31 May 2016 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5892275
18 February 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs · Inclining Experiment
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5819771

Deficiency record · 99

01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 August 2024 Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. This letter sets forth conditions of operation….” Marine Inspector observed foam blocks established by the current stability letter to be not properly installed. Outfit vessel with foam block arrangement in accordance with the vessel’s current stability letter. 46 CFR 170.120
Action required: 705 - Other - as specified
Due 5 September 2024
Resolved 11 October 2024
Resolution: All blocks in place
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 August 2024 Resolved
(a) “All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.” Marine Inspector identified a bolt at the air induction for the forward generator that was sticking out unable to be tightened due to stripped threads. 46 CFR 183.05 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Bolt replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024 Resolved
“Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat….” Marine Inspector identified battery installation not properly secured under the bridge console. 46 CFR 183.05-20 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Battery covered and strapped down
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 August 2024 Resolved
“A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.” Marine Inspector identified expired first aid kits onboard. Outfit vessel with first aid kits that are not expired. 46 CFR 121.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: purchased new 1st aid kit
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2024 Resolved
“Twist-on type connectors may not be used for making joints in cables, facilitating a conductor splice, or extending the length of a circuit.” Marine Inspector identified twist on type connectors (wire nuts) all around vessel including, but not limited to under the pilot house and behind the DJ booth on the uppermost deck. 46 CFR 120.340
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Electrical connections of approved type
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 August 2024 Resolved
“Installation of diesel engine exhaust pipe shall be in accordance with § 182.15-20...Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gastight throughout its length and shall be properly supported by noncombustible hangers or blocks.” Marine Inspector identified exhaust leak by the starboard exhaust stack on the 1st deck. Determine source of leak and provide repair plan. 46 CFR 182.20-20 OLD T; 46 CFR 182.15-20 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Exhaust leak fixed with new steel schedule 40 pipe
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 29 August 2024 Resolved
“Air-cooled propulsion and auxiliary engines installed below deck as permitted by § 182.20-10 shall be fitted with air intake ducts or piping from the weather deck. The ducts or piping shall be so arranged and supported to be capable of safely sustaining stresses induced by weight and engine vibration and to minimize transfer of vibration to the supporting structure…” Marine Inspector Identified natural ventilation gooseneck by the starboard exhaust stack to be not connected. Outfit vessel with connection to the existing gooseneck. 46 CFR 182.20-45 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: USCG MI observed goosenecks fastened
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 29 August 2024 Resolved
"(b) The minimum number of mariners holding a license or MMC officer endorsement as mate required to be carried on... every inspected, seagoing, passenger vessel must not be less than the following,...(4) All vessels of less than 100 GRT—one mate (except vessels on voyages not exceeding 12 hours in duration may, if the OCMI determines it to be safe, be operated without mates)." "...The recommended experience for the SENIOR DECKHAND is:1. 30 days experience on board the vessel. 2. 30 hours at the helm under supervision of a master or mate... thevessel's master should designate the SENIORDECKHAND in writing and a copy of this designation should be retained on board the vessel." To operate without req'd mate within SEC NY, OCMI requires full compliance with NVIC 1-91. USCG MI observed no designation letter onboard or logs of req'd training for the crew identified as senior deckhands. 46 CFR 15.810; NVIC 1-91
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: Senior Dkhands designated in writing
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 August 2024 Resolved
"The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable." USCG MI observed several trash bins constructed of plastic, a petroleum product. Replace bins with suitable incombustible material such as metal to mitigate fire hazards. 46 CFR 177.10-5 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: Metal trash cans onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 August 2024 Resolved
"(b) Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection." Mount fire extinguisher on the bridge. 46 CFR 181.30-10 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 6 September 2024
Resolution: Extinguisher mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2024 Resolved
"(b) Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided..." Engine cooling water temperature gauge not operational on the stbd generator. 46 CFR 182.20-5(b) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Gage replaced and functions
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 August 2024 Resolved
"Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed..." The reduction gear's oil gauge is not suitably mounted to a bracket. 46 CFR 182.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2024
Resolved 11 October 2024
Resolution: Gage mounted
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 19 February 2020 Resolved
Grind out and re-weld the underside of the insert in the male head under the toilet. The top of the weld was not inspected and will require inspection prior to clearing. If the top side of the weld is in similar shape as the underside. The insert should be ground out and re-welded on both sides to the satisfaction of the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The insert was properly welded.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 February 2020 Resolved
Make full repairs as discussed to the crack discovered in the bow rub rail. A new piece of U-channel shall be fitted and welded in place. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The crack was caused by an inpact at the bow. It was re-welded and stopped. The POC plans on re-fitting the area during the next DD period.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 19 February 2020 Resolved
Grind down and fill small hole in the rub rail decking by the bow. The area should be cleaned and inspected by the attending marine inspector prior to any paint in the area. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The hole was properly filled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 February 2020 Resolved
Crop out and replace 5 brackets and decking as identified along the Port side rub rail. Once the brackets are fitted the area shall be made available to the attending marine inspector prior to fitting the deck plating. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The rub rail was fully repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 February 2020 Resolved
Gauge area identified along the centerline just aft of the centerline keel cooler to determine steel thickness. Report finding to the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The inset was gauged and determined to have less than 5% wastage in the area. No action required.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 February 2020 Resolved
Remove interior bulkhead covering and crop and renew steel on the STBD transom where a 16" long hole was discovered along the deck plating. The area shall be cropped to good steel as discussed and fit-up made available for inspection to the attending marine inspector prior to final welding. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new steel plate was fitted.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 February 2020 Resolved
The hole discovered in the STBD rudder post shall be cleaned-out to bare metal and filled. Once filled the area shall be made available to the attending marine inspector prior to painting. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new steel plate was fitted.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 19 February 2020 Resolved
The old sewage discharge hole on the STBD side shall be cropped and renewed with an approx. 18"xl8" insert. The interior bulkhead coverings shall be removed and a fitup shall be proven to the attending marine inspector prior to final welding. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new steel was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the 1st and 2nd longitudinal above the chine on the Port side shall be cropped and renewed where marked or to good metal. The longitudinals shall be made available to inspect the final welds. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: New longitunidnals were fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 February 2020 Resolved
In the Laz, 05 gussets were missing and shall be replaced along the port side of the forward bulkhead. Once welded, the final welds shall be made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: New gussets were installed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, along the portside overhead, two longitudinals near the forward bulkhead were discovered to be cropped out and never replaced. The longitudinals shall be re-welded in place and final welds made available for the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: New members were fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the longitudinal just aft of the sewage tank port-side edge shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitnidinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the STBD #5 longitudinal (from centerline) shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitudinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, The STBD #6 (from centerline) (tall structure member) shall be cropped where marked or to good metal. Once the area is cropped, a fit-up shall made available for the attending marine inspector prior to final welds. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: The frame insert was completed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the STBD #7 longitudinal (from centerline) shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitudinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the STBD #7 vertical frame (from the centerline) on the forward bulkhead shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new frame was fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 February 2020 Resolved
In the Laz, the #8 longitudinal (from centerline) shall be cropped and renewed where marked or to good metal. The longitudinal shall be re-welded in place and final welds made available for the attending marine inspector. Prior to credit DD.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new longitudinal was fitted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2020 Resolved
Vessel shall be safe from electrical shock of personnel. On 2/5/2020, a USCG Marine Inspector received a shock while touching the hull of the M/V QUEEN OF HEARTS. Determine the cause of the electrical shock and effect necessary repairs to satisfaction of attending Marine Inspector. 46 CFR "Old T" 183.01-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: All electrical panels and boards were inspected, cleaned, and several conductors were re-affixed to the proper terminals. The cause of the shock was not identified but is believed to be corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
All conductors shall be of the stranded type. Replace or remove any solid core wiring found. Any replacement wires must comply with 46 CFR 120.240. -46 CFR "Old T" 183.05-45(b) -46 CFR 120.115(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: Solid core was removed.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
Wiring joints and splices shall be mechanically secure. Any splices found that are not made with a mechanical connection shall be redone or removed. New splices need to comply with 46 CFR 120.340. -46 CFR "Old T" 183.01-5 -46 CFR 120.115(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: Wires were properly spliced.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
Each grounding wire shall have green insulation. If a existing grounding wire that is not green is found, it shall be marked at both ends with green tape. -46 CFR 120.372(d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: Grounds were properly attached.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 7 February 2020 Resolved
Remove "dead end" wires from all distribution panels, switch-boards, junction boxes, etc to the satisfaction of attending Marine Inspector. -46 CFR "Old T" 183.01-5
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2020
Resolution: dead-end wires were removed or terminated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2020 Resolved
Illegal pigtail/shoretie found connected to engine room 110V/220V panel. Corrected on the spot. -46 CFR "Old T" 183.01-5
Action required: 60 - Rectify deficiencies prior to movement
Due 7 February 2020
Resolved 7 February 2020
Resolution: Immediately removed pigtail from panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2019 Resolved
Conduct casualty analysis report, repair transmission clutch actuator and conduct sea trials to the satisfaction of a USCG Marine Inspector. 46 CFR 155.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2019
Resolved 8 November 2019
Resolution: Replaced actuator and conducted sea trials.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 November 2019 Resolved
Identify fault on fire detection panel and properly repair detector / fire control panel. 46 CFR 115.810(a)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2019
Resolved 8 November 2019
Resolution: Fire detection equipment was serviced. ALL SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 November 2019 Resolved
Starboard MDE has oil leak. Make permanent repairs to MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 November 2019
Resolved 8 November 2019
Resolution: Vessel provided video footage attesting to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2019 Resolved
Observed multiple electrical hazards in engine room; loose wires, dead end wires, loose/disconnected conduits, missing protective covers for breaker panel in galley, and multiple daisy-chained electrical extension chords. Make proper repairs to all electrical issues identified.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Made proper repairs to issued identified during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2019 Resolved
Conduct satisfactory bilge pump and bilge system test in the presence of a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Observed satisfactory test of bilge pump and bilge system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 9 September 2019 Resolved
Found loose pressure gauge on the 471 Generator. Properly secure loose pressure gauge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Item secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2019 Resolved
Found numerous life jackets with improper vessel name marking. Properly mark life jackets with full vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Life jackets marked with vessel name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2019 Resolved
Provide heat resistant specs for fuel sight gauges located on the port and starboard fuel tanks. If unable to provide specs, install heat resistant sight gauges with adequate protection to prevent damage to sight gauge. Fuel sight gauges must have automatic shut off devices in case of fuel line rupture.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 April 2020
Resolution: The sight gauge was removed and capped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2019 Resolved
Observed electrical panel cover located in concession stand on main deck have "zipties" as hinges. These ziptie hinges must be removed and replaced with proper hinges.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Zipties removed and replaced with proper support brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2019 Resolved
The bilge suction head located in Void 1C is missing bilge strainer. Install bilge strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Bilge strainer reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2019 Resolved
The hertz meter gauge located on the main switch board panel for service generator is not working. Repair/replace non functional hertz meter.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: meter repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 September 2019 Resolved
Space storing carbon dioxide is missing proper warning sign. Place proper warning sign where carbon dioxide is stored i.a.w. 46 CFR 122.612(i)(1).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 September 2019
Resolution: Marking installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2019 Resolved
BILGE HIGH LEVEL ALARM IS NOT SECURELY ATTACHED. CITE: 46CFR182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 13 September 2019
Resolution: Bilge attached
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2019 Resolved
THE VESSEL QUEEN OF HEARTS IS A SPV-TL, THEREFORE NOT REQUIRED A SAFETY MANAGEMENT SYSTEM (SMS) PER REGULATION. SECTOR NY HAS FOUND THE FOLLOWING DEFICIENCIES TO BE OBJECTIVE EVIDENCE THAT A SERIOUS SUBSTANDARD CONDITION HAS NOT BEEN PRO-ACTIVELY MANAGED BY THE VESSEL'S OWNER/OPERATOR, LEADING TO A LACK OF SAFETY CULTURE ONBOARD THE VESSEL.
Action required: 30 - Ship detained
Resolved 13 September 2019
Resolution: Attneded vessel to conduct def follow-up and overall operation of vessel. All 701's were cleared to satisfaction of attending MI's. Re-issued vessels COI.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 August 2019 Resolved
REPAIRS OR ALTERATIONS TO THE HULL, MACHINERY, OR EQUIPMENT THAT AFFECT THE SAFETY OF THE VESSEL MUST NOT BE MADE WITHOUT THE APPROVAL OF THE COGNIZANT [name withheld] DISCOVERED IN LAZARETTE SPACE. VESSEL ENGINEER INITIALLY DENIED KNOWLEDGE OF UNAUTHORIZED REPAIR. UPON FURTHER QUESTIONING, HE ADMITTED TO KNOWLEDGE OF FLOODING AT THE RATE OF 3 CUPS PER MINUTE AND APPLYING AN UNAUTHORIZED EPOXY PATCH TO THE RUPTURE OOA 3 WEEKS AGO. NO REPAIR PLANS WERE SUBMITTED TO THE [name withheld] TEMPORARY REPAIR PROPOSAL AND TRANSIT PROPOSAL DELINEATING THE ROUTE AND MEASURES THAT WILL BE TAKEN ONBOARD TO ENSURE A SAFE TRANSIT, INCLUDING MITIGATING PROGRESSIVE FLOODING, TO A LOCAL SHIPYARD FOR PERMANENT REPAIRS.
Action required: 30 - Ship detained
Resolved 21 August 2019
Resolution: Proper repairs were made to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 14 August 2019 Resolved
WHENEVER THERE IS A HAZARDOUS CONDITION ONBOARD THE VESSEL, THE OWNER, MASTER, AGENT OR PERSON IN CHARGE SHALL IMMEDIATELY NOTIFY THE CAPTAIN OF THE PORT. NO REPORTS WERE MADE TO THE CAPTAIN OF THE PORT FOR THE RUPTURE LOCATED IN THE LAZARETTE SPACE. VESSEL ENGINEER ADMITTED TO KNOWLEDGE OF STEEL RUPTURE.
Action required: 30 - Ship detained
Resolved 21 August 2019
Resolution: Educated operator of reporting requirements
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 August 2019 Resolved
THE BILGES AND OTHER SPACES MAY BE EXAMINED TO SEE THAT THERE IS NO EXCESSIVE ACCUMULATION OF OIL THAT MIGHT CREATE A FIRE HAZARD. EGREGIOUS ACCUMULATION OF APPROX. 2 GALLONS OF OIL DISCOVERED IN ENGINE ROOM BILGES. VESSEL REQUIRED TO PROVIDE CAUSAL ANALYSIS FOR SOURCE, EFFECT REPAIR, AND REMOVE OIL FROM ALL BILGES FOR INSPECTION.
Action required: 30 - Ship detained
Resolved 13 September 2019
Resolution: Bilges clean
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 14 August 2019 Resolved
AT EVERY VESSEL INSPECTION, QUARTERS, TOILET AND WASHING SPACES, GALLEYS, SERVING PANTRIES, LOCKERS, AND SIMILAR SPACES MAY BE EXAMINED TO DETERMINE THAT THEY ARE SERVICEABLE AND IN A SANITARY CONDITION. ALL AFOREMTIONED SPACES WERE FOUND TO BE IN DISARRAY AND IN AN UNSANITARY CONDITION. VESSEL MUST ENSURE ALL SPACES ARE CLEAN AND ORGANIZED TO MITIGATE THE RISK OF ENDANGERMENT TO CREW AND PASSENGERS. MAKE READY FOR INSPECTION.
Action required: 30 - Ship detained
Resolved 13 September 2019
Resolution: Cleaniness of all spaces were completed
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 14 August 2019 Resolved
ALL OBSERVED UNSAFE PRACTICES, FIRE HAZARDS AND OTHER HAZARDOUS SITUATIONS MUST BE CORRECTED. ALL 6 PORTABLE EXTINGUISHERS AND THE INSTALLED FIRE SUPPRESSION SYSTEM WERE DELINQUENT ON SERVICING AS OF JUNE 2019. ALL FIRE SAFETY EQUIPMENT MUST BE SERVICED TO INCLUDE A SATISFACTORY TEST OF INSTALLED FIRE PROTECTION SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: Servcing of fixed and portable fire extinguishing systems were completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 August 2019 Resolved
ALL OBSERVED UNSAFE PRACTICES, FIRE HAZARDS AND OTHER HAZARDOUS SITUATIONS MUST BE CORRECTED. NUMEROUS ELECTRICAL HAZARDS EXIST ONBOARD INCLUDING DAISY-CHAINED POWER CORDS, EXPOSED WIRING IN ENCLOSURES, AND EXPOSED DEAD END WIRES IN LIGHTING. VESSEL MUST REMOVE DAISY-CHAINED POWER CORDS, PLACE DEAD COVERS IN ALL ENCLOSURES AND PLACE ALL EXPOSED WIRING IN AN ENCLOSURE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2019
Resolution: ALl electrical issues were rectified
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 September 2019
Resolution: DAPI audit was completed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 November 2018 Resolved
Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 2 June 2022
Resolution: Operator demonstrated to MI while on inspection that AIS has been updated.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 October 2018 Resolved
Vessel subject to hull inspection for superstructure and similar arrangements. Vessel stbd quarter damaged during docking maneuvers. Prepare and submit for approval repair plan to CG Marine Inspectors. Approval must be given prior to starting work.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2018
Resolved 26 October 2018
Resolution: Completed repairs see narrative.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 October 2018 Resolved
Prepare and submit repair plan for two threaded openings in lazarette space (one port and one stbd).
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2018
Resolved 26 October 2018
Resolution: Completed repairs see narrative.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 September 2018 Resolved
Minimum capacity of fire pump shall be 50 gallons per minute at a pressure not less than 60 psi. Upon testing operation of vessels fire pump, the pumps psi gauge was reading a consistent 38 psi.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2018
Resolution: Vessel proved proper operation of fire pump.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2018 Resolved
Spaces containing flammable and combustible materials must have a fixed fire extinguishing system. Flammable and combustible materials were found throughout the vessel in unprotected spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2018
Resolution: Vessel removed all flammable and combustible materials.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
Vessel must have on board alcohol test strips . Alcohol test strips were expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2018 Resolved
Vessel more than 65 ft must carry on board 03 lifebuoys of 24 inches IAW 46 CFR 160.050 of Subchapter Q. One of vessel's lifebuoys had a hole and all of vessels lifebuoy lanyards are not of an approved type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2018
Resolution: Vessel replaced life buoy and all lanyards
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 4 September 2018 Resolved
Tubular sight glasses must be of heat resistant materials and have connections with devices that automatically close in the event of rupture. The port side fuel tank sight glass is not connected at all. It is wrapped around the port cover with a rag stuffed in the end. The connection devices do not automatically close. Rubber tubing used as sight glasses has not been proved to be heat resistant.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 4 September 2018 Resolved
MI identified a sewage leak in the toilet facility area. Toilet facility area is not in a sanitary condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
MI identified unsafe conditions throughout the vessel. A/C compressor units are not secured.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 September 2018 Resolved
Vessels fire detection system must comply with the regulations of this part. Vessels fire detection panel was displaying a troubleshooting alarm and crew was unable to rectify.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 September 2018 Resolved
Vessel must carry a first aid approved under 160.041 of Subchapter Q or a kit with equivalent contents or instructions. Vessel did not have an approved type first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Provided adequate kit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2018 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval from the cognizant OCMI. Vessel installed welding wire and LED lights and has changed the location/configuration of battery banks located in the engine room. Vessel is to submit an electrical line drawing to the OCMI and MSC for review and approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 2 June 2022
Resolution: MI verified that all plans have been submitted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2018 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MI identified splices and dead end wires throughout the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Properly dead-ended wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2018 Resolved
An adult life jacket must be provided for each person on board the vessel. 8 life jackets were found to have deteriorated retro material. Total persons allowed is 416.
Action required: 705 - Other - as specified
Resolved 25 September 2018
Resolution: Purchased 8 new PFDs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed must be indicated by a durable marking at least 1 inch at the entranceway to that deck. Vessel did not have markings for 2nd and 3rd deck, both are limited by stability criteria.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: labeled decks properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 September 2018 Resolved
All wires and cables must be ran as high as practical above the bilges. Battery cables were ran on the deck through out the bilges in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 17 March 2020
Resolution: Cables have been re-attached and run above the bilge.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
At each inspection bilges and other spaces may be examined for excessive accumulation of oil, trash , and debris that might create a fire hazard, clog bilge pumping system, or block emergency exits. There was an excessive amount of oil and debris found in the engine room bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 September 2018
Resolved 25 September 2018
Resolution: Bilges clean.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 September 2018 Resolved
At each inspection all observed unsafe practices or hazardous situations must be corrected. The aft stairs are not bolted down or secured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Secured stairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 September 2018 Resolved
Portable watertight containers for distress flares and smoke signals shall be clearly marked "DISTRESS SIGNALS". Vessel's portable container was unmarked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: labeled container.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 September 2018 Resolved
At each inspection, inspection of all accessible parts of the exterior and interior of the hull, watertight and weather-tight bulkheads and decks shall be prepared. The bulkhead to the forward deck is not weather-tight. There is a penetration from an ice machine line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: Filled penetration with fire-stop.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 September 2018 Resolved
Piping conveying vapor, gas, or liquid of which temperature exceeds 150 degrees F must be insulated to prevent injuries. The exhaust piping on the port MDE is not fully insulated. It is only partially insulated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 23 October 2018
Resolution: Insulated piping.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 4 September 2018 Resolved
The cognizant OCMI may require any additional tests or inspections to determine that the vessel and its equipment are suitable for intended service. A significant flex in the deck located on the 2nd deck next to the balcony, port side was identified. Vessel is to sand down area and make ready for inspection for the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2018
Resolved 25 September 2018
Resolution: tack welds under deck cracked- no concern for tripping hazard or impact to strength of deck. Stitch welds for deck surrounding all in tact.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 August 2018 Resolved
Vessel has an expired VSP. Vessel is restricted to 150 passengers until provide vaild VSP.
Action required: 705 - Other - as specified
Due 20 August 2018
Resolved 23 August 2018
Resolution: Vessel submitted ASP Letter to MSC.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 April 2018 Resolved
Remove wooden storage doors and replace with steel as original.
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 4 September 2018
Resolution: vessel removed wooden doors and replaced with then steel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 March 2018 Resolved
Vessel is past due for drydock inspection and is restricted from carrying passengers until credit drydock is completed by CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2018
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 September 2017 Resolved
Complete first annual inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2017
Resolution: Completed annual inspection.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 September 2017 Resolved
Prove processing of Certificate of Documentation application from NVDC.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2017
Resolution: Attended vessel and operator had applying to renew the COD.
Documentation › Certificates/Documents › FCC SSL
Issued 5 September 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 7 September 2017
Resolution: Attended vessel and examined a valid FCC SSL.
Documentation › Logs/Records › Drug Test Records
Issued 5 September 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 13 September 2017
Resolution: Employees will not serve in a safety sesitive position until records are provided to the USCG.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 5 September 2017 Resolved
Post up to date and accurate fire control plan; make accessible to passengers.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 5 September 2017 Resolved
Re-label vessel name on life rings located on main and upper decks.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Electrical › Electric Supply System (service) › Battery Charger
Issued 5 September 2017 Resolved
Provide ammeter for wheelhouse battery charger.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 7 September 2017
Resolution: Attended vessel and digital meter was found acceptable.
Engineering › Bilge Water Management System › Strainer
Issued 5 September 2017 Resolved
Provide new strainer for bilge system in fuel tank void.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 13 September 2017
Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 5 September 2017 Resolved
Prove proper operation of generator shut down pressure switch.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Electrical › Electric Supply System (service) › Battery Charger
Issued 5 September 2017 Resolved
Properly wire battery chargers in engine room.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Fire Fighting › Combustible Materials › Facings/Mouldings/Decorations/Veneers
Issued 5 September 2017 Resolved
Remove stowed carpet from from shaft space.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 5 September 2017 Resolved
Properly mount sewage pump in lazarette.
Action required: 705 - Other - as specified
Due 4 October 2017
Resolved 13 September 2017
Engineering › Bilge Water Management System › Piping
Issued 5 September 2017 Resolved
Permanently attach remote forepeak valve for bilge system.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 5 September 2017 Resolved
Post emergency instructions IAW 46 CFR 122.510
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 5 September 2017 Resolved
Provide crew list & pre-employment documentation for Drug & Alcohol Program.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Personnel › Training › Passenger Safety
Issued 5 September 2017 Resolved
Designate senior deckhand in writing.
Action required: 705 - Other - as specified
Due 13 September 2017
Resolved 13 September 2017
Stability › Unintentional Flooding › General
Issued 31 May 2016 Resolved
Vessel will not fill the fuel or sewage tanks more than 50% until damage stability is met.
Action required: 705 - Other - as specified
Resolved 17 March 2020
Resolution: A new stability letter was issued.

Casualty record · 6

8 February 2011Routine · role: Involved in a Marine Casualty · activity 3961422
4 June 2011Routine · role: Involved in a Marine Casualty · activity 4036918
4 July 2012Routine · role: Involved in a Marine Casualty · activity 4368418
29 August 2012Routine · role: Involved in a Marine Casualty · activity 4426998
4 November 2019Routine · role: Involved in a Marine Casualty · activity 6849421
6 May 2023Routine · role: Involved in a Marine Casualty · 1 injured · activity 7809831
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

FIRST LADY (2011–2012), QUEEN OF HEARTS (2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.