Records from 2004 to 2025. Most recent: inspection, 3 October 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 26
3 October 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8239657
23 October 2024
Hull Examination · Drydock Exam · Internal Structural Exam · In-Service Inspection · Inclining Experiment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8023736
14 June 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7935104
14 June 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7937262
10 April 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7893278
10 April 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899655
24 May 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7695948
16 March 2023
Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7651589
31 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7522148
31 July 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7546642
24 May 2022
Internal Structural Exam · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7448766
20 April 2022
Inclining Experiment
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7447951
10 March 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7409785
30 July 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7272552
24 May 2021
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7201487
3 February 2021
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7134112
11 December 2020
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7110627
11 March 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6925000
27 September 2019
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6857770
7 March 2019
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6637738
26 February 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6638964
8 March 2018
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6368035
29 December 2017
Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6330193
2 February 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6081419
29 November 2016
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6048999
16 March 2016
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5842713
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2025
Resolved
A vessel must be provided with a piping system that meets 56.50-50 in subchapter F of this chapter. Crew unable to demonstrate satisfactory suction from engine room bilge pipe.
46 CFR 119.510
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2025
Resolved 21 November 2025
Resolution: Witnessed suction from both e/r pick ups.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2025
Resolved
All microprocessor or computer based systems must meet the requirements of part 62 in subchapter F of this chapter. Technician unable to complete engine overspeed DVTP based on as built limitations. Provide documentation from OEM or demonstrate test in compliance with DVTPs.
46 CFR 121.620
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2025
Resolution: Witnessed overspeed DVTP.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 October 2025
Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate high water level in each of the following spaces: A space with a through-hull fitting below the deepest load waterline. Aft battery void missing high water alarm.
46 CFR 119.530
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2025
Resolution: Verified installation and operation of alarm.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 October 2025
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by boundaries that prevent the passage of vapors. Engine room door that opens to main deck accommodation space has a gap at the bottom that is not vapor tight.
46 CFR 116.405
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 21 November 2025
Resolution: Verified vapor tightness of door.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2025
Resolved
Each individual bilge suction shall be fitted with a suitable bilge stainer. Lazarette bilge strainer found broken and no longer capable of blocking debris.
46 CFR 56.50-50
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 21 November 2025
Resolution: Verified replaced strainer installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 October 2025
Resolved
The minimum capacity f the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Local fire pump pressure gauge maxes out at 60 psi and spikes all the way around to zero when energized. Replace gauge with higher readout to give accurate indication of pressure.
46 CFR 181.10-1 (Old T)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 21 November 2025
Resolution: Verified installation of new gauge and sat operation.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 October 2025
Resolved
A distribution line must extend at least 2 inches beyond the last orifice and be closed with a cap or plug. Fire suppression piping in port aft engine room ends with discharge horn and does not have 2 inch extension.
46 CFR 118.410
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2025
Resolved 21 November 2025
Resolution: Verified installation of 2" pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 October 2025
Resolved
At each inspection for certification of a vessel, the operator shall be prepared to conduct tests and have the vessel ready for inspection of machinery…including the following: inspection of all machinery essential to the routine operation of the vessel including generators and cooling systems. Number one chill water pump in auxiliary machinery space missing on/off switch.
46 CFR 115.804
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 21 November 2025
Resolution: Verified switch installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 October 2025
Resolved
At each inspection for certification of a vessel, the operator shall be prepared to conduct tests of electrical equipment including the following: inspection of all cable as far as practicable. Multiple dead end wires present in engine room at the base of the stairs on the bulkhead.
46 CFR 115.806
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 5 December 2025
Resolution: Verified correction of dead end wires.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 3 October 2025
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. First-aid kit found with expired medicines.
46 CFR 121.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2025
Resolved 21 November 2025
Resolution: Verified validity of medical kit items.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 October 2025
Resolved
At each inspection for certification of a vessel, the operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull, including the following: inspection of all accessible parts of the exterior and interior of the hull. Fractured gusset found in starboard side of steering void, located two frames back from the forward bulkhead.
46 CFR 115.802
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2025
Resolved 5 December 2025
Resolution: Accepted photo of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of propulsion on both main engines. Provide root cause and repair issue to the satisfaction of the Marine Inspector.
46 CFR 119.200(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2025
Resolution: Verified proper operation of engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 April 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of propulsion. Provide root cause and repair issue to the satisfaction of the Marine Inspector. 46CFR119.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2024
Resolved 31 May 2024
Resolution: Company provide root cause details and conducted sat sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 April 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Modifications have been made to propulsion control and alarm systems since original casualty/installation. OCMI is not confident that the equipment on board matches what is approved and the validity of the currently approved DVTP. Submit all modifications and updates to DVTP to MSC for approval and testing by the OCMI.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2024
Resolved 3 October 2025
Resolution: New DVTP testing completed.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 May 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices must be corrected. The vessel's forward fire station door on the second deck was unable to be opened in a suitable manner.
46 CFR 115.830(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 5 June 2023
Resolution: Received photo.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 May 2023
Resolved
Each life jacket kept in a stowage container must be readily available. The vessel's 2nd deck lifejacket storage is missing a handle.
46 CFR 117.78(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 5 June 2023
Resolution: Received photo.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 August 2022
Resolved
Vessels to which this subchapter applies must meet the applicable provisions in subchapter S (Subdivision and Stability) of this chapter. Vessel found to have a leak in the watertight bulkhead between engine room and sewage tank void space. Submit repair proposal and make repairs after approval.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2022
Resolution: Vessel welded repairs and conducted satisfactory NDT to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of propulsion. Cause of LOP must be investigated and repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2022
Resolution: Attending MI witnessed satisfactory repairs made to the generator coupling.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 31 July 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Vessel reported back flow of seawater into void space due to faulty check valve on the bilge manifold. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2022
Resolution: Attending MI witnessed satisfactory repairs and replacement of bilge check valves.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 May 2022
Resolved
Each survival craft must be secured with by a painter with a float-free link permanently attached to the vessel…stowed so that the when the vessel sinks the survival craft floats free and, if inflatable inflates automatically. IBAs were found with painter/inflation lanyard unattached.
46 CFR 117.130(a)(1) & (2)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 10 June 2022
Resolution: Painter properly attached.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Temporary battery charger found charging house batteries under bridge console.
46 CFR 120.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 10 June 2022
Resolution: Permanent battery charger properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2022
Resolved
Electrical equipment exposed to the weather must be watertight. Electrical outlet on port quarter of main deck is missing cover.
46 CFR.210(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 10 June 2022
Resolution: Watertight electrical cover installed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 May 2022
Resolved
Each opening in an exposed weather deck must have a means for closing it weather tight. Coaming on main deck aft doors is bent and not allowing doors to fully close.
46 CFR 171.122(f)(1) "Old S"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2022
Resolved 1 June 2022
Resolution: Door properly closes, ensureing weathertight condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 May 2022
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened from either side. Forepeak/Galley escape hatch has T handle stored inside hatch. Therefore, this hatch is only able to be opened from one side.
46 CFR 118.425(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2022
Resolved 10 June 2022
Resolution: T handle installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 May 2022
Resolved
A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system meeting the applicable sections of NFPA 17. Galley hood does not have an inspected and certified system in place. No cooking in galley until system is installed and certified.
46 CFR 118.425(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 June 2022
Resolution: Servicing complete.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 24 May 2021
Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel does not have a magnetic compass. Must install magnetic compass.
46CFR121.402(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2022
Resolution: Received photo of magnetic compass installed on bridge.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 May 2021
Resolved
Doors in A-Class fire control boundaries must meet the following additional requirements: A door must not be undercut more than 12.7 millimeters (0.5 inches) above the door sill or deck covering. Rugs and carpets must not pass through doorways, but linoleum and similar deck coverings may. Carpet passes under doors leading to forward stairway on maindeck. Must remove carpet passing under door.
46CFR116.(c)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 10 August 2021
Resolution: Operator installed threshold under doorway.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 May 2021
Resolved
A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test for the applicable time period listed below, the average temperature on the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181 °C (325 °F) above the original temperature. Insulation was found falling off the overhead over the stairs leading into the auxiliary machinery space. Ensure insulation is installed properly.
46CFR116.415(a)(2)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 10 August 2021
Resolution: Insulation was properly installed on overhead below stairs.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021
Resolved
Each portable fire extinguisher on a vessel must be of a type approved by the Commandant. Galley fire extinguisher is not Coast Guard approved. Replace with approved fire extinguisher.
46CFR118.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 10 March 2022
Resolution: Received photo of proper fire extinguisher installed in galley.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 September 2019
Resolved
The vessel removed 12.88LT of batteries and battery equipment from the third void (battery compartment). The vessel will replace the batteries at latter date. The following restrictions will be imposed on the vessel until a new stability test is complete:
1. The vessel is restricted to the carriage of 500 passengers and a max persons count of 550.
2. The potable water tanks are required to be pressed up daily to counteract the loss of the forward weight.
Action required: 705 - Other - as specified
Due 15 January 2020
Resolved 1 June 2022
Resolution: Verified condition of forepeak ballast as per stability letter.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 8 March 2018
Resolved
Support CO2 manifold piping.
Due 22 March 2018
Resolved 11 June 2018
Fire Fighting › Grease Extraction Hood › General
Issued 8 March 2018
Resolved
Prove galley hood extinguishing system is installed IAW NFPA 17A.
Due 22 March 2018
Resolved 11 June 2018
Fire Fighting › Fixed Fire Detection System › Approval
Issued 29 November 2016
Resolved
Fire detection Panel is unapproved. Vessel will have till next Dry Dock 31Jan2019 to replace with a Coast Guard approved fire panel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 April 2019
Resolved 16 February 2021
Resolution: Fire Panel is approved under Coast Guard Approval number 161.002 60 0
Fire Fighting › Fire Patrol › Call Points
Issued 29 November 2016
Resolved
Submit company roving fire watch policy to Coast Guard.
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 13 September 2017
Resolution: Received fire watch policy.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 16 March 2016
Resolved
Obtain and display emergency escape sign near emergency escape ladder in auxiliary room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 March 2016
Resolved 4 May 2016
Resolution: Vessel put emergency escape sign near escape ladder in the auxiliary room.