Records from 1991 to 2025. Most recent: inspection, 16 December 2025.
Documentation record
Registered dimensions (L × B × D)54.3 ft × 22.0 ft × 7.6 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCRUMPLERS SHIPBLDG CO INC · ORANGE, TX, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
16 December 2025
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8292104
1 November 2024
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8034938
30 July 2024
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7970384
26 July 2023
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7759899
22 June 2023
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7650696
8 November 2021
Damage Survey · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7347907
8 November 2021
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7348345
22 June 2021
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7232911
29 September 2012
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4490438
25 April 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4288883
16 November 2010
Industry Initiated Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3898992
6 March 2001
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 289887
12 May 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 55147
22 October 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 409446
10 January 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 374122
16 June 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 59234
22 July 1991
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 659122
22 July 1991
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 659123
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Received report of marine casualty in which PORT side generator caught fire (damaging hot end of generator unit.)Prove proper operation of the PORT side generator to the attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 June 2021
Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. Inspection found the emergency remote fuel shutoffs did not function.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2022
Resolution: Attended vessel, deficiency corrected.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 22 June 2021
Resolved
It is the responsibility of the crew to minimize any distraction from the operation of the vessel or performance of duty. Inspection found a fire alarm strobe light/horn on the bridge, which could cause a safety hazard to navigation of the vessel.
Action required: 10 - Deficiency Rectified
Resolved 2 June 2022
Resolution: Corrected prior to departure of inspector.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 June 2021
Resolved
A 40-B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a). Inspection found no 40 B extinguisher in vicinity of flammable storage cabinet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 3 June 2022
Resolution: Attended vessel, deficiency corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 June 2021
Resolved
The following systems must be equipped with gauges at the machinery location: Main Engine RPM. Inspection found port and starboard main engines had no RPM gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 13 June 2022
Resolution: Received objective evidence from POC of RPM gauges being installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 22 June 2021
Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Inspection found no rails or equivalent from main deck's structure forward on port and starboard sides or around periphery of second deck bow between push knees.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2022
Resolved 3 June 2022
Resolution: Attended vessel, deficiency corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 22 June 2021
Resolved
Each towing vessel must be equipped with at least two portable battery-powered lights. One must be located in the pilothouse and the other at the access to the engine room. Inspection found no portable light at the access to the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2022
Resolved 3 June 2022
Resolution: Attended vessel, deficiency corrected.
Electrical
Issued 6 March 2001
Resolved
Missing blank in breaker panel on bridge was replaced.
Condition: Unknown
Due 6 April 2001
Resolved 8 May 2001
Electrical
Issued 6 March 2001
Resolved
Missing light covers were installed.
Condition: Unknown
Due 6 April 2001
Resolved 8 May 2001