Records from 1994 to 2025. Most recent: inspection, 30 April 2025.
Documentation record
Registered dimensions (L × B × D)56.8 ft × 21.4 ft × 8.5 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHRIFT SHIPBUILDERS & REP · SULPHUR, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDH6770MMSI 366991080 · active · compulsorily equipped · granted 2 July 2024, expires 23 September 2034
WDC2317MMSI 366991080 · cancelled · compulsorily equipped · granted 16 November 2004, cancelled 9 August 2011
WQZ8475MMSI not assigned · expired · voluntarily equipped · granted 29 November 1994, cancelled 12 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s
MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 17
30 April 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8123876
2 March 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7646821
4 January 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7375598
6 July 2021
Deficiency Check · Administrative Inspection · Initial Certification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7246813
1 August 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2732599
11 July 2006
MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2709674
16 June 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2392931
30 December 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2266525
8 December 2004
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 2263634
8 December 2004
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 2321283
3 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2022491
25 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2009419
30 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 177914
29 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 186842
26 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 88075
25 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 25840
7 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 100742
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2021
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings and electrical equipment and systems, must: (1) Be maintained to ensure proper operation; (2) Be suitable for routes and service; and (3) Have suitable propulsion controls to provide operator full control. Vessel's starboard shaft was leaking during inspection.
46CFR143.205(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 26 August 2021
Resolution: Leak was corrected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 July 2021
Resolved
Electrical systems and equipment must be marked with its respective current and voltage ratings. Several distribution panels throughout the boat weren't marked with its corresponding voltage and current ratings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 26 August 2021
Resolution: Markings were appropriate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Several circuit breakers on the wheelhouse's distribution panel weren't labeled.
46CFR143.400(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 26 August 2021
Resolution: Loads were appropriately labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. The connections of flexible cable plugs and socket outlets must be designed to prevent unintended separation. Both of the magnetic pick-up cables for each propulsion engine were suspended in the air and improperly secured. Splice and termination of both cables were not insulated or properly secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 July 2026
Resolved 27 August 2021
Resolution: Vessel used an LB to terminate connections. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2021
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Several electrical connection terminals underneath the wheelhouse control station were openly exposed without any enclosure.
46CFR143.400(g)
Vessel was allowed an extension on the deficiency due to intricacy of repair. Vessel will need to have repair made by next drydock 2026.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 4 January 2022
Resolution: Accepted TPO report from ABS and photo documentation as sufficient to clear def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 July 2021
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejackets containers must be marked in block capital letters and numbers with the minimum quantity, identity, and if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container. Lifejackets containers throughout the vessel were missing proper marking.
46CFR141.340(h)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2021
Resolved 26 August 2021
Resolution: All lifejacket containers were properly labeled.